Plan Review Stops For Permit 04061029 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-09-22 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-09-22 |
Time |
14:08 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
2004-09-22 |
Time |
14:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-07-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-09-21 |
Time |
11:06 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2004-07-07 |
Time |
13:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-09-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-09-21 |
Time |
11:06 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2004-09-21 |
Time |
10:49 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-06-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-24 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2004-06-25 |
Time |
11:16 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-08-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-26 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-26 |
Time |
10:22 |
Sent To |
P |
|
Notes |
2004-08-26 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-07-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-27 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-27 |
Time |
15:45 |
Sent To |
P |
|
Notes |
2004-07-27 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-06-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-24 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-06-24 |
Time |
08:55 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-06-23 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-06-23 |
Time |
09:02 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2004-09-22 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-09-22 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2004-09-22 |
Time |
14:08 |
Sent To |
|
|
Notes |
2004-09-22 00:00:00 | PER KS 9/20/04 LS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2004-08-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-26 |
Time |
10:23 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-08-10 |
Time |
12:38 |
Sent To |
|
|
Notes |
2004-08-10 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 1 | | | | FROM PREVIOUS REVIEW: | | 1) POOL LAYOUT SHALL REFLECT THE DRAIN | | DETAIL. DRAIN DETAIL SHOWS PIPING FOR | | MAIN DRAINS AND SPA DRAIN CONNECTING AT | | THE CENTER OF THE DRAINS, BUT POOL LAY- | | OUT SHOWS THE PIPING OFFSET FROM CENTER | | OF DRAINS. THESE SUCTION INLETS SHALL BE | | PLUMBED SUCH THAT WATER IS DRAWN THROUGH | | THEM SIMULTANEOUSLY. SECTION 424.2.6.6.4 | | PLEASE CORRELATE DETAIL WITH POOL LAYOUT | | SECTION 104.2.1. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-07-07 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-27 |
Time |
15:45 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2004-07-07 |
Time |
11:54 |
Sent To |
B |
|
Notes |
2004-07-07 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | FBC-2001 CHAPTER 1 | | | | 1) POOL LAYOUT SHALL REFLECT THE DRAIN | | DETAIL. DRAIN DETAIL SHOWS PIPING FOR | | MAIN DRAINS AND SPA DRAIN CONNECTING AT | | THE CENTER OF THE DRAINS, BUT POOL LAY- | | OUT SHOWS THE PIPING OFFSET FROM CENTER | | OF DRAINS. THESE SUCTION INLETS SHALL BE | | PLUMBED SUCH THAT WATER IS DRAWN THROUGH | | THEM SIMULTANEOUSLY. SECTION 424.2.6.6.4 | | PLEASE CORRELATE DETAIL WITH POOL LAYOUT | | SECTION 104.2.1. | | 2) WHITE OUT AND HAND WRITTEN DETAILS OR | | NOTES ARE NOT APPROVED ON SIGNED & SEAL- | | ED PLANS. SECTION 104.2.1.3. | | 3) PLEASE CHANGE NOTE #2 TO READ ANSI- | | NSPI-5 (STANDARD FOR RESIDENTIAL SWIMM- | | ING POOLS). HAS BEEN ANSI-NSPI 4 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-23 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-06-23 |
Time |
14:58 |
Sent To |
I |
|
Notes |
|
|