Plan Review Details - Permit 04060880
Plan Review Stops For Permit 04060880
Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2006-01-30 Cont ID  
Sent By shill Date 2006-01-30 Time 14:48 Rev Time 0.00
Received By shill Date 2006-01-30 Time 14:48 Sent To  
Notes
2006-01-30 00:00:00REVISION, WINDOW FIX

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2005-11-30 Cont ID  
Sent By shill Date 2005-11-30 Time 10:23 Rev Time 0.50
Received By shill Date 2005-11-30 Time 10:22 Sent To PC
Notes
2005-11-30 00:00:00CHANGE WINDOWS TO IMPACT

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2005-08-11 Cont ID  
Sent By shill Date 2005-08-11 Time 09:57 Rev Time 0.00
Received By shill Date 2005-08-11 Time 09:57 Sent To  
Notes
2005-08-11 00:00:00TRUSS ENGINEERING

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2005-04-04 Cont ID  
Sent By shill Date 2005-04-04 Time 15:15 Rev Time 0.00
Received By shill Date 2005-04-04 Time 15:15 Sent To  
Notes
2005-04-04 00:00:00HOLLOW CORE ENGINEERING SEE 04060859

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-03-07 Cont ID  
Sent By shill Date 2005-03-07 Time 15:26 Rev Time 2.00
Received By shill Date 2005-03-07 Time 15:26 Sent To M
Notes
2005-03-07 00:00:00PROVISO - AT RISK PERMIT
 REVISE S2.1 - S2.3

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2005-01-27 Cont ID  
Sent By shill Date 2005-01-27 Time 15:14 Rev Time 0.00
Received By shill Date 2005-01-27 Time 15:14 Sent To  
Notes
2005-01-27 00:00:00WITH THE EXCEPTION OF THE USE OF THE
 EXISTING RETAINING WALL AND THE USE OF
 SHINGLES ON THE ROOF, SEE COMMENTS FOR
 04060867

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-01-27 Cont ID  
Sent By shill Date 2005-01-27 Time 15:05 Rev Time 2.00
Received By shill Date 2005-01-27 Time 15:05 Sent To  
Notes
2005-01-27 00:00:00WITH THE EXCEPTION OF THE USE OF THE
 EXISTING RETAINING WALL AND THE USE OF
 SHINGLES ON THE ROOF, SEE COMMENTS FOR
 04060856

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-12-14 Cont ID  
Sent By shill Date 2004-12-14 Time 11:31 Rev Time 2.00
Received By shill Date 2004-12-14 Time 11:31 Sent To PC
Notes
2004-12-14 00:00:00SEE 04060856

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-07-23 Cont ID  
Sent By shill Date 2004-07-23 Time 17:41 Rev Time 1.00
Received By shill Date 2004-07-23 Time 17:41 Sent To  
Notes
2004-07-23 00:00:00SEE 04060887

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-10-27 Cont ID  
Sent By dpalmer Date 2004-10-27 Time 15:31 Rev Time 0.33
Received By dpalmer Date 2004-10-27 Time 15:31 Sent To  
Notes
2004-10-27 00:00:00NOTED 2002 NEC

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-06-24 Cont ID  
Sent By dpalmer Date 2004-06-24 Time 09:47 Rev Time 0.33
Received By dpalmer Date 2004-06-24 Time 09:47 Sent To  
Notes
2004-06-24 00:00:00************ UNSAT **************
 BLDG 11
 1)NOTE: PLEASE SHOW ALL CIRCUITING ON
 PLANS AND CORRELATE WITH THE SUBMITTED
 PANLEL SCHEDULE.
  
 2)NOTE: PLEASE NOTE ON PLANS SD'S PER
 NFPA-72 8-1.4.2
 3'FROM BATH DOORS/KITCHEN. 20' FROM
 COOKING APPLIANCES. PLEASE ALSO SEE
 EXCEPTIONS.
  
 3)NOTE: PLEASE SEE FAC 61G15-23.002,
 AND FS 471.023.
 PLEASE INCLUDE ALL REQUIRED LICENS #'S
 ON TITLE BLOCK.
 PLEASE SEE ATTACHED PRINT OUT FROM DBPR'
 S WEB SITE. FIRM AS SHOWN ON TITLE BLOCK
 IS SHOWN AS HAVING A "CLOSED" LICENSE.
  
 4)NOTE: PLEASE SEE CLOSET LT AND TYPE
 OF FIXTURE AND DISTANCE FROM SHELVES
 PER 410.8
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-11-23 Cont ID  
Sent By nmccray Date 2004-11-23 Time 14:28 Rev Time 0.00
Received By nmccray Date 2004-11-23 Time 14:28 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-06-24 Cont ID  
Sent By mcarsill Date 2004-06-24 Time 10:27 Rev Time 0.00
Received By mcarsill Date 2004-06-24 Time 10:27 Sent To  
Notes
2004-06-24 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO, DURING AND AFTER CONSTRUCTION.
  
 2) BUILDING ADDRESSES REQUIRED.
  
 3) PRESCRIPTIVE STRENGTH REQUIREMENTS
 SHALL BE SHOWN ON PLANS FOR ALL
 HANDRAILS AND GUARDRAILS.
  
 4) IS THE DOOR BETWEEN THE GARAGE AND
 THE STAIRS RATED. NO RATING DOOR SHOWN
 ON DOOR SCHEDULE.
  
 5) SMOKE DETECTORS SHALL BE PLACED A
 MINIMUM OF THREE FEET FROM AIR
 CONDITIONER DIFFUSERS.
  
 6) NO FIRE SPRINKLER DRAWINGS PROVIDED
 WITH PLANS. PAGE A-1 INDICATES THAT THE
 BUILDING WILL BE FIRE SPRINKLER
 PROTECTED.
  
 7) NO INFORMATION PROVIDED REGARDING
 THE MONITORING OF THE FIRE SPRINKLER
 SYSTEM.
  
 8) SITE PLAN DOES NOT DISPLAY ANY
 FIRE HYDRANTS.
  
 9) NO MENTION OF ANY FIRE EXTINGUISHERS
  
 COURTESY REVIEW PERFORMED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-09-28 Cont ID  
Sent By adarroug Date 2005-09-28 Time 16:28 Rev Time 0.00
Received By adarroug Date 2005-09-28 Time 16:27 Sent To M
Notes
2005-09-28 00:00:00TO "M" BOX

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-09-12 Cont ID  
Sent By adarroug Date 2005-09-12 Time 08:51 Rev Time 0.00
Received By adarroug Date 2005-09-12 Time 08:51 Sent To B
Notes
2005-09-12 00:00:00TO "SHILL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-05-05 Cont ID  
Sent By adarroug Date 2005-05-05 Time 08:56 Rev Time 0.00
Received By adarroug Date 2005-05-05 Time 08:56 Sent To B
Notes
2005-05-05 00:00:00TO "SHILL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-03-01 Cont ID  
Sent By adarroug Date 2005-03-01 Time 08:41 Rev Time 0.00
Received By adarroug Date 2005-03-01 Time 08:41 Sent To  
Notes
2005-03-01 00:00:00TO "COMM" BD#36/"COMM" RACK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-01-06 Cont ID  
Sent By mjacobs Date 2005-01-06 Time 11:40 Rev Time 0.00
Received By mjacobs Date 2005-01-06 Time 11:40 Sent To  
Notes
2005-01-06 00:00:00TO "COMM BD#19/PLANS ON RACK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-10-14 Cont ID  
Sent By csiegber Date 2004-10-14 Time 11:52 Rev Time 0.00
Received By csiegber Date 2004-10-14 Time 11:52 Sent To  
Notes
2004-10-14 00:00:00TO COMM BD#21/PLANS ON RACK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-07-23 Cont ID  
Sent By shill Date 2004-07-23 Time 17:41 Rev Time 0.00
Received By shill Date 2004-06-18 Time 12:00 Sent To  
Notes
2004-06-18 00:00:00TO COMM BD#24

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-10-20 Cont ID  
Sent By tgordon Date 2005-10-20 Time 08:36 Rev Time 0.30
Received By tgordon Date 2005-10-20 Time 08:36 Sent To  
Notes
2005-10-20 00:00:00MECH. REV. PLANS AND E. CAL..

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-03-08 Cont ID  
Sent By pkrauss Date 2005-03-08 Time 09:46 Rev Time 0.10
Received By pkrauss Date 2005-03-08 Time 09:46 Sent To B
Notes
2005-03-08 00:00:00BUILDING 11
 APPROVED 12-1-04 - NO CHANGES ON THE
 RESUBMITTAL.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-12-01 Cont ID  
Sent By pkrauss Date 2004-12-01 Time 17:16 Rev Time 0.10
Received By pkrauss Date 2004-12-01 Time 17:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-07-20 Cont ID  
Sent By pkrauss Date 2004-07-20 Time 07:21 Rev Time 0.35
Received By pkrauss Date 2004-07-20 Time 07:21 Sent To  
Notes
2004-07-20 00:00:00DENIED:"BORDEAUX MODEL" END-UNIT
 1.PLEASE NOTE, PER 2001 FBC(M) 104.2.1
 EACH PERMIT APPLICATION REQUIRES 2
 COPIES OF PLANS AND SPECIFICATIONS.
 PLEASE PROVIDE ADDITIONAL COPIES.
  
 2.RETURN AIR JUMPERS FROM THE MASTER
 BEDROOM IS NOT SIZED PROPERLY.PER THE
 REVISED 2001 FBC(M) 601.4 EXCEPTION #1;
 TRANSFER DUCTS SHALL BE A MINIMUM OF 1
 1/2 TIMES THE SQUARE INCHES OF THE
 SUPPLY AIR TO THAT SPACE.EXCEPTION #3;
 ALL AIR INTO THE MASTER SUITE TO BE
 INCLUDED.SEE THE ATTACHED SCHEDULE FOR
 PROPER SIZING FOR THE RETURN AIR JUMPERS
  
 3.PLEASE CLARIFY THE RATING OF THE
 SEPARATION WALL BETWEEN THE GARAGE AND
 THE RESIDENCE.
  
 4.PROVIDE OUTSIDE AIR CALCULATIONS PER
 2001 FBC(M) 402.2, 402.2.1 OR 403.3.
  
 5.AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED PER 2001 FBC(M)
 307.2.3.
  
 6.PLANS ARE TO BE SIGNED AND DATED BY
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE HVAC SYSTEM IN ACCORDANCE WITH THE
 FLORIDA STATUTES AND THE FLORIDA
 ADMINISTRATION CODE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-01-31 Cont ID  
Sent By kstevens Date 2005-01-31 Time 11:17 Rev Time 0.33
Received By kstevens Date 2005-01-31 Time 11:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-11-12 Cont ID  
Sent By kstevens Date 2004-11-12 Time 14:29 Rev Time 0.33
Received By kstevens Date 2004-11-12 Time 14:29 Sent To  
Notes
2004-11-12 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 SEE COMMENTS FROM PERMIT #04060880

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-07-19 Cont ID  
Sent By kstevens Date 2004-07-19 Time 14:38 Rev Time 0.25
Received By kstevens Date 2004-07-19 Time 14:38 Sent To  
Notes
2004-07-19 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SHT P.4 TUB IN BATH #2 THIRD FLOOR IS
 NOT VENTED. SECTION 901.2.1
  
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2004-10-25 Cont ID  
Sent By eschneid Date 2004-10-25 Time 14:53 Rev Time 0.25
Received By eschneid Date 2004-10-25 Time 14:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-06-30 Cont ID  
Sent By mmclean Date 2004-06-30 Time 13:41 Rev Time 0.00
Received By mmclean Date 2004-06-30 Time 13:41 Sent To  
Notes
2004-06-30 00:00:00DENIED, NEED TO PROVIDE PLAT WITH 41
 LOTS WITH ENGINEERING PLANS (2 SETS).
 NEED TO PROVIDE LANDSCAPE PLANS. CALL
 ERIC SCHNEIDER, SENIOR PLANNER AT 659-
 8031 FOR ANY QUESTIONS.