Plan Review Details - Permit 04060877
Plan Review Stops For Permit 04060877
Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2005-11-30 Cont ID  
Sent By shill Date 2005-11-30 Time 16:22 Rev Time 0.50
Received By shill Date 2005-11-30 Time 16:22 Sent To PC
Notes
2005-11-30 00:00:00REVISION - CHANGE WINDOWS

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2005-08-11 Cont ID  
Sent By shill Date 2005-08-11 Time 10:10 Rev Time 0.00
Received By shill Date 2005-08-11 Time 10:10 Sent To  
Notes
2005-08-11 00:00:00TRUSS ENGINEERING

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2005-04-06 Cont ID  
Sent By shill Date 2005-04-06 Time 08:12 Rev Time 0.50
Received By shill Date 2005-04-06 Time 08:12 Sent To PC
Notes
2005-04-06 00:00:00REVISION DATED 3/21/05 (FFE CHANGE)
 FEES PAID AND SUBMITTED UNDER 04060877

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2005-04-04 Cont ID  
Sent By shill Date 2005-04-04 Time 15:20 Rev Time 0.00
Received By shill Date 2005-04-04 Time 15:20 Sent To  
Notes
2005-04-04 00:00:00HOLLOW CORE ENGINEERING, SEE 04060859

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-03-08 Cont ID  
Sent By shill Date 2005-03-08 Time 10:41 Rev Time 1.00
Received By shill Date 2005-03-08 Time 10:41 Sent To PC
Notes
2005-03-08 00:00:00PROVISO
  
 AT RISK PERMIT
 REVISE SHEETS S2.1 - S2.3
 REVISE SITE PLAN TO SHOW DISTANCE
 BETWEEN BLDG 12 AND CABANA > 3' TO
 ASSUMED PROPERTY LINE

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2005-03-03 Cont ID  
Sent By shill Date 2005-03-03 Time 09:10 Rev Time 1.00
Received By shill Date 2005-03-03 Time 09:10 Sent To  
Notes
2005-03-03 00:00:00SEE 04060876

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-01-27 Cont ID  
Sent By shill Date 2005-01-27 Time 15:57 Rev Time 0.00
Received By shill Date 2005-01-27 Time 15:57 Sent To  
Notes
2005-01-27 00:00:00SEE 04060867, COMMENTS 1, 2,4,5,6,12

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-12-14 Cont ID  
Sent By shill Date 2004-12-14 Time 16:42 Rev Time 0.00
Received By shill Date 2004-12-14 Time 16:42 Sent To PC
Notes
2004-12-14 00:00:00SEE 04060856
 WITH EXCEPTION OF PORCH ISSUE
  
 SEE 1ST LIST IN REGARDS TO DIMENSIONS ON
 SITE PLAN; PROVIDE DISTANCE BETWEEN UNIT
 AND CABANA FOR TABLE 600 COMPLIANCE
 REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-07-23 Cont ID  
Sent By shill Date 2004-07-23 Time 19:20 Rev Time 1.00
Received By shill Date 2004-07-23 Time 19:20 Sent To  
Notes
2004-07-23 00:00:00SEE 04060887

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-10-27 Cont ID  
Sent By dpalmer Date 2004-10-27 Time 14:24 Rev Time 0.33
Received By dpalmer Date 2004-10-27 Time 14:24 Sent To  
Notes
2004-10-27 00:00:00NOTED 2002 NEC
 NO GAZEBO ON THIS PERMIT!.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-06-24 Cont ID  
Sent By dpalmer Date 2004-06-24 Time 16:44 Rev Time 0.25
Received By dpalmer Date 2004-06-24 Time 16:44 Sent To  
Notes
2004-06-24 00:00:00PLEASE SEE NOTES UNDER 04060876

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-11-23 Cont ID  
Sent By nmccray Date 2004-11-23 Time 10:55 Rev Time 0.00
Received By nmccray Date 2004-11-23 Time 10:55 Sent To  
Notes
2004-11-23 00:00:00PROVISO FIRE SPRINKLER SYSTEM SHALL BE
 MONITORED BY UL LISTED FIRE ALARM AND
 CENTRAL STATION

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-06-24 Cont ID  
Sent By mcarsill Date 2004-06-24 Time 12:46 Rev Time 0.00
Received By mcarsill Date 2004-06-24 Time 12:46 Sent To  
Notes
2004-06-24 00:00:00PLEASE SEE PERMIT # 04060876 FOR
 COMMENTS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-03-01 Cont ID  
Sent By adarroug Date 2005-03-01 Time 08:53 Rev Time 0.00
Received By adarroug Date 2005-03-01 Time 08:53 Sent To  
Notes
2005-03-01 00:00:00TO "COMM" BD#36/COMM RACK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-01-06 Cont ID  
Sent By mjacobs Date 2005-01-06 Time 13:49 Rev Time 0.00
Received By mjacobs Date 2005-01-06 Time 13:49 Sent To  
Notes
2005-01-06 00:00:00TO "COMM BD#19

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-10-14 Cont ID  
Sent By csiegber Date 2004-10-14 Time 11:05 Rev Time 0.00
Received By csiegber Date 2004-10-14 Time 11:05 Sent To  
Notes
2004-10-14 00:00:00TO COMM BD#21/PLANS ON RACK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-07-23 Cont ID  
Sent By shill Date 2004-07-23 Time 19:20 Rev Time 0.00
Received By shill Date 2004-06-18 Time 12:00 Sent To  
Notes
2004-06-18 00:00:00TO COMM BD#24

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-10-20 Cont ID  
Sent By tgordon Date 2005-10-20 Time 08:51 Rev Time 0.30
Received By tgordon Date 2005-10-20 Time 08:51 Sent To  
Notes
2005-10-20 00:00:00MECH. REV. PLANS AND E. CAL..

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-12-01 Cont ID  
Sent By pkrauss Date 2004-12-01 Time 17:22 Rev Time 0.10
Received By pkrauss Date 2004-12-01 Time 17:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2004-11-18 Cont ID  
Sent By pkrauss Date 2004-11-18 Time 06:34 Rev Time 0.35
Received By pkrauss Date 2004-11-18 Time 06:26 Sent To  
Notes
2004-11-18 00:00:00DENIED: BUILDING 12 UNIT 40 & 41
  
 COMMENT #2 FROM REVIEW DATED 7-16-04 WAS
 NOT ADDRESSED; R/A JUMPER FROM THE
 MASTER BEDROOM IN BOTH UNITS ARE NOT
 SIZED IN ACCORDANCE WTIH 2001 FBC(M)
 601.4 EXCEPTION #1 & 3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS @ (561)805-6719.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-07-19 Cont ID  
Sent By pkrauss Date 2004-07-19 Time 07:01 Rev Time 0.25
Received By pkrauss Date 2004-07-19 Time 07:01 Sent To  
Notes
2004-07-19 00:00:00DENIED:
 1.PLEASE CLARIFY RATING OF THE
 SEPARATION WALL BETWEEN THE GARAGE AND
 THE RESIDENCE.PLEASE NOTE, PLAN SHEET
 M-5, 8" FLEX DUCT PENETRATES THE
 SEPARATION BETWEEN THE GARAGE & DEN.
  
 2.RETURN AIR JUMPERS FROM BOTH MASTER
 BEDROOMS ARE NOT SIZED PROPERLY.PER
 THE REVISED 2001 FBC(M) 601.4 EXCEPTION
 #1; TRANSFER DUCTS SHALL BE A MINIMUM OF
 1 1/2 TIMES THE SQUARE INCHES OF THE
 SUPPLY AIR TO THAT SPACE.EXCEPTION #3;
 ALL AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED.SEE THE ATTACHED SCHEDULE FOR
 PROPER SIZING OF RETURN AIR JUMPERS.
  
 3.AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED PER 2001 FBC(M)
 307.2.3.
  
 4.PROVIDE OUTSIDE AIR CALCULATIONS
 PER 2001 FBC(M) 402.2 & 402.2.1 OR 403.3
  
 5.PLANS ARE TO BE SIGNED AND DATED BY
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE HVAC SYSTEM IN ACCORDANCE WITH THE
 FLORIDA STATUTES AND THE FLORIDA
 ADMINSTRATIVE CODE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-01-31 Cont ID  
Sent By kstevens Date 2005-01-31 Time 12:58 Rev Time 0.37
Received By kstevens Date 2005-01-31 Time 12:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-11-12 Cont ID  
Sent By kstevens Date 2004-11-12 Time 17:50 Rev Time 0.25
Received By kstevens Date 2004-11-12 Time 17:50 Sent To  
Notes
2004-11-12 00:00:00DENIED
  
  
 SEE COMMENTS FROM PERMIT #04060876

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-07-17 Cont ID  
Sent By kstevens Date 2004-07-17 Time 17:39 Rev Time 0.25
Received By kstevens Date 2004-07-17 Time 17:39 Sent To  
Notes
2004-07-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SHT P.4 SANT. RISER DIAGRAM DOES NOT
 MEET CODE REQUIREMENTS, TUB IN BATH #2
 THIRD FLOOR IS NOT VENTED. SEC 901.2.1
  
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2004-10-25 Cont ID  
Sent By eschneid Date 2004-10-25 Time 14:54 Rev Time 0.25
Received By eschneid Date 2004-10-25 Time 14:54 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-06-30 Cont ID  
Sent By mmclean Date 2004-06-30 Time 13:43 Rev Time 0.00
Received By mmclean Date 2004-06-30 Time 13:42 Sent To  
Notes
2004-06-30 00:00:00DENIED, NEED TO PROVIDE PLAT WITH 41
 LOTS WITH ENGINEERING PLANS (2 SETS).
 NEED TO PROVIDE LANDSCAPE PLANS. CALL
 ERIC SCHNEIDER, SENIOR PLANNER AT 659-
 8031 FOR ANY QUESTIONS.