Plan Review Stops For Permit 04060876 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
9 |
Status |
P |
Date |
2005-11-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-11-30 |
Time |
16:13 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2005-11-30 |
Time |
16:13 |
Sent To |
|
|
Notes |
2005-11-30 00:00:00 | REVISION - CHANGE WINDOWS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
P |
Date |
2005-08-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-08-11 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-08-11 |
Time |
10:10 |
Sent To |
|
|
Notes |
2005-08-11 00:00:00 | TRUSS ENGINEERING |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2005-05-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-05-12 |
Time |
17:39 |
Rev Time |
0.25 |
Received By |
shill |
Date |
2005-05-12 |
Time |
17:39 |
Sent To |
PC |
|
Notes |
2005-05-12 00:00:00 | STEEL SHOPS, 04060876 AND 04060877 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2005-04-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-04-04 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-04-04 |
Time |
15:19 |
Sent To |
|
|
Notes |
2005-04-04 00:00:00 | HOLLOW CORE ENGINEERING, SEE 04060859 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2005-03-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-03-08 |
Time |
10:05 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2005-03-08 |
Time |
10:05 |
Sent To |
PC |
|
Notes |
2005-03-08 00:00:00 | PROVISO - | | | | AT RISK PERMIT | | REVISE SHEETS S2.1 - S2.3 | | REVISE SITE PLAN TO SHOW DISTANCE | | BETWEEN BLDG 12 AND CABANA > 3' TO | | ASSUMED PROPERTY LINE |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2005-03-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-03-03 |
Time |
09:07 |
Rev Time |
2.00 |
Received By |
shill |
Date |
2005-03-02 |
Time |
14:07 |
Sent To |
|
|
Notes |
2005-03-03 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)PROVIDE INFORMATION PREVIOUSLY | | REQUESTED TO DETERMINE TABLE 600 | | COMPLIANCE.AS PER DISCUSSION WITH | | ARCHITECT, THIS INFORMATION WILL BE SENT | | VIA FAX. | | | | 2.)THIS PERMIT WILL BE ISSUED AS AN | | AT-RISK PERMIT. | | | | 3.)THE PLANS DECLARE A NON SPRINKLED | | BUILDING, AND THE FIRE SPRINKLER PLANS | | PREVIOUSLY IN THE PACKAGE ARE NOW GONE. | | HOWEVER, THE HYDRAULIC CALCS FOR THE | | FIRE SPRINKLERS ARE STILL IN THE PERMIT | | PACKAGE AND THE FIRE REVIEW HAS A | | PROVISO RELATED TO FIRE SPRINKLERS. | | PLEASE CLARIFY. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-01-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-01-27 |
Time |
15:51 |
Rev Time |
2.00 |
Received By |
shill |
Date |
2005-01-27 |
Time |
15:51 |
Sent To |
|
|
Notes |
2005-01-27 00:00:00 | SEE 04060867, COMMENTS 1, 2, 4, 5, 6, | | 12 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-12-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-12-14 |
Time |
16:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2004-12-14 |
Time |
16:30 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-07-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-07-23 |
Time |
19:19 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2004-07-23 |
Time |
19:19 |
Sent To |
|
|
Notes |
2004-07-23 00:00:00 | SEE 04060877 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-10-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-10-27 |
Time |
14:25 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-10-27 |
Time |
14:11 |
Sent To |
|
|
Notes |
2004-10-27 00:00:00 | NOTED 2002 NEC | | NO GAZEBO ON THIS PERMIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-06-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-24 |
Time |
16:37 |
Rev Time |
0.55 |
Received By |
dpalmer |
Date |
2004-06-24 |
Time |
16:37 |
Sent To |
|
|
Notes |
2004-06-24 00:00:00 | ************ UNSAT ************* | | BLDG #12 | | | | 1)NOTE; PLEASE SHOW ALL CIRCUITING ON | | PLANS AND CORRELATE WITH THE SUBMITTED | | PANEL SCHEDULE. | | | | 2)NOTE: PLEASE SEE NFPA-72 8-1.4.2 FOR | | SD LOCATIONS. 3'FROM BATHS/KITCHENS AND | | SUPPLY AIR. 5'RA, 20' FRO COOKING APPL | | W/ EXCEPTIONS. | | | | 3)NOTE: PLEASE SHOW A/C CU DISC'S 440.11 | | | | 4)NOTE: PLEASE SEE MISPRINT FOR 210.12 | | 2002 NEC | | | | 5)NOTE: PLEASE SEE LOAD CALCULATIONS | | SHOWS CU LOAD AS BEING GREATER THAN | | AHU HEAT? PLEASE CORRELATE WITH MECH | | PLANS. | | | | 6)NOTE: PLEASE SEE FAC61G15-23.002, | | FS 471.023 | | PLEASE INCLUDE ALL REQUIRED LICENSE | | #'S ON TITLE BLOCKS. | | PLEASE SEE FIRM SHOWN ON TITLE BLOCK | | SHOWS AS HAVING A "CLOSED" LICENSE ON | | DBPR WEBSITE. PLEASE SEE ATTACHED COPY. | | REQUIRED ON ALL SHEETS AND FOR ALL | | TRADES WHEATHER OR NOT COMMENT IS MADE | | FROM THAT REVIEWER. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-11-23 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2004-11-23 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2004-11-23 |
Time |
11:01 |
Sent To |
|
|
Notes |
2004-11-23 00:00:00 | PROVISO FIRE SPRINKLER SYSTEM SHALL BE | | MONITORED BY UL LISTED FIRE ALARM AND | | CENTRAL STATION |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2004-06-24 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-06-24 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-06-24 |
Time |
12:40 |
Sent To |
|
|
Notes |
2004-06-24 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | TO, DURING AND AFTER CONSTRUCTION. | | | | 2) BUILDING ADDRESSES REQUIRED. | | | | 3) PRESCRIPTIVE STRENGTH REQUIREMENTS | | SHALL BE SHOWN ON PLANS FOR ALL | | HANDRAILS AND GUARDRAILS. | | | | 4) IS THE DOOR BETWEEN THE GARAGE AND | | THE STAIRS RATED. NO RATING SHOWN ON | | DOOR SCHEDULE. | | | | 5) SMOKE DETECTORS SHALL BE PLACED A | | MINIMUM OF THREE FEET FROM AIR | | CONDITIONER DIFFUSERS. | | | | 6) NO FIRE SPRINKLER DRAWINGS PROVIDED | | WITH PLANS. PAGE A.1 INDICATES THAT | | THE BUILDING WILL BE FIRE SPRINKLER | | PROTECTED. | | | | 7) NO INFORMATION PROVIDED REGARDING | | MONITORING OF THE FIRE SPRINKLER SYSTEM. | | | | 8) SITE PLAN DOES NOT DISPLAY ANY | | FIRE HYDRANTS. | | | | 9) NO MENTION OF ANY FIRE EXTINGUISHERS. | | | | COURTESY REVIEW PERFORMED. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2005-09-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-28 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-28 |
Time |
16:48 |
Sent To |
M |
|
Notes |
2005-09-28 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-09-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-12 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-12 |
Time |
08:52 |
Sent To |
B |
|
Notes |
2005-09-12 00:00:00 | TO "SHILL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-05-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-05 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-05 |
Time |
08:33 |
Sent To |
B |
|
Notes |
2005-05-05 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-03-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-01 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-01 |
Time |
08:51 |
Sent To |
|
|
Notes |
2005-03-01 00:00:00 | TO "COMM" BD#36/COMM RACK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-06 |
Time |
13:47 |
Sent To |
|
|
Notes |
2005-01-06 00:00:00 | TO "COMM BD#19/RESUB. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
|
Date |
2004-10-14 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-14 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-14 |
Time |
10:47 |
Sent To |
|
|
Notes |
2004-10-14 00:00:00 | TO COMM BD#21/PLANS ON RACK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-07-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-07-23 |
Time |
19:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2004-06-18 |
Time |
11:59 |
Sent To |
|
|
Notes |
2004-06-18 00:00:00 | TO COMM BD#24 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2005-10-20 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-10-20 |
Time |
08:46 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2005-10-20 |
Time |
08:46 |
Sent To |
|
|
Notes |
2005-10-20 00:00:00 | MECH. REV. PLANS AND E. CAL.. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2004-12-01 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-12-01 |
Time |
17:17 |
Rev Time |
0.10 |
Received By |
pkrauss |
Date |
2004-12-01 |
Time |
17:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2004-11-17 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-11-17 |
Time |
17:51 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2004-11-17 |
Time |
17:37 |
Sent To |
|
|
Notes |
2004-11-17 00:00:00 | DENIED: BUILDING 12 UNIT 40 & 41 | | | | COMMENT #2 FROM REVIEW DATED 7-16-04 WAS | | NOT ADDRESSED; R/A JUMPER FROM MASTER | | BEDROOM IN BOTH UNITS ARE NOT SIZED IN | | ACCORDANCE WITH 2001 FBC(M)601.4 | | EXCEPTION #1 & 3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS @ (561)805-6719. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-01-31 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-07-19 |
Time |
06:35 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2004-07-19 |
Time |
06:05 |
Sent To |
|
|
Notes |
2004-07-19 00:00:00 | DENIED: | | 1.PLEASE CLARIFY RATING OF THE | | SEPARATION WALL BETWEEN THE GARAGE AND | | THE RESIDENCE.PLEASE NOTE, PLAN SHEET | | M-5 8" FLEX DUCT PENETRATES THE | | SEPARATION BETWEEN THE GARAGE & DEN. | | | | 2.RETURN AIR JUMPERS FROM BOTH MASTER | | BEDROOMS ARE NOT SIZED PROPERLY.PER | | THE REVISED 2001 FBC(M) 601.4 EXCEPTION | | #1; TRANSFER DUCTS SHALL BE A MINIMUM OF | | 1 1/2 TIMES THE SQUARE INCHES OF THE | | SUPPLY AIR TO THAT SPACE.EXCEPTION #3; | | ALL AIR INTO THE MASTER SUITE SHALL BE | | INCLUDED.SEE THE ATTACHED SCHEDULE FOR | | PROPER SIZING OF RETURN AIR JUMPERS. | | | | 3.AUXILIARY DRAIN PAN WITH OVERFLOW | | PROTECTION REQUIRED PER 2001 FBC(M) | | 307.2.3. | | | | 4.PROVIDE OUTSIDE AIR CALCULATIONS | | PER 2001 FBC(M) 402.2 & 402.2.1 OR 403.3 | | | | 5. PLANS ARE TO BE SIGNED & DATED BY THE | | PERSON RESPONSIBLE FOR THE DESIGN OF THE | | HVAC SYSTEM IN ACCORDANCE WITH THE | | FLORIDA STATUTES & THE FLORIDA | | ADMINISTRATIVE CODES. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2005-01-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-01-31 |
Time |
12:52 |
Rev Time |
0.51 |
Received By |
kstevens |
Date |
2005-01-31 |
Time |
12:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2004-11-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-11-12 |
Time |
17:46 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-11-12 |
Time |
17:46 |
Sent To |
|
|
Notes |
2004-11-12 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW: | | 1) SHT P.4 SANT. RISER DIAGRAM DOES NOT | | MEET CODE REQUIREMENTS, TUB IN BATH #2 | | THIRD FLOOR IS NOT VENTED. SECTION | | 901.2.1. | | | | NEW COMMENT: | | 1B) SEE ATTACHED SHEET CONCERNING THE | | DESIGN PROFESSIONAL AND FS 553.80(2)(B) | | | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-07-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-07-17 |
Time |
17:32 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2004-07-17 |
Time |
17:32 |
Sent To |
|
|
Notes |
2004-07-17 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | SHT P.4 SANT. RISER DIAGRAM DOES NOT | | MEET CODE REQUIREMENTS, TUB IN BATH #2 | | THIRD FLOOR IS NOT VENTED. SEC 901.2.1 | | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | SHEET. IF PRACTICING THROUGH A DULY | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | THEIR NAME AND LICENSE NUMBER, AS WELL | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | AUTHORIZATION NUMBER OF THE ENGINEERING | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | WILL SATISFY THIS REQUIREMENT. FAC | | 61G15-23.002(2) - FS 471.025 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2004-10-25 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2004-10-25 |
Time |
14:54 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2004-10-25 |
Time |
14:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2004-06-30 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-06-30 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-06-30 |
Time |
13:42 |
Sent To |
|
|
Notes |
2004-06-30 00:00:00 | DENIED, NEED TO PROVIDE PLAT WITH 41 | | LOTS WITH ENGINEERING PLANS (2 SETS). | | NEED TO PROVIDE LANDSCAPE PLANS. CALL | | ERIC SCHNEIDER, SENIOR PLANNER AT 659- | | 8031 FOR ANY QUESTIONS. |
|
|