Plan Review Stops For Permit 04060856 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
9 |
Status |
P |
Date |
2005-11-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-11-30 |
Time |
14:09 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2005-11-30 |
Time |
14:09 |
Sent To |
PC |
|
Notes |
2005-11-30 00:00:00 | REVISION - CHANGE WINDOWS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
P |
Date |
2005-08-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-08-11 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-08-11 |
Time |
09:46 |
Sent To |
|
|
Notes |
2005-08-11 00:00:00 | TRUSS ENGINEERING |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2005-04-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-04-04 |
Time |
15:23 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2005-04-04 |
Time |
15:23 |
Sent To |
|
|
Notes |
2005-04-04 00:00:00 | DENSITIES |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2005-04-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-04-04 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-04-04 |
Time |
15:09 |
Sent To |
|
|
Notes |
2005-04-04 00:00:00 | HOLLOW CORE ENGINEERING, SEE 04060859 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2005-03-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-03-30 |
Time |
12:16 |
Rev Time |
1.50 |
Received By |
shill |
Date |
2005-03-30 |
Time |
12:16 |
Sent To |
PC |
|
Notes |
2005-03-30 00:00:00 | PROVISO | | | | AT RISK PERMIT, SEE LETTER | | | | THE DECLARATION OF COVENANTS AND | | RESTRICTIONS TO BE AMENDED AS AGREED | | WITH THE BUILDING OFFICIAL |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2005-03-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-03-07 |
Time |
13:56 |
Rev Time |
2.00 |
Received By |
shill |
Date |
2005-03-07 |
Time |
13:56 |
Sent To |
PC |
|
Notes |
2005-03-07 00:00:00 | SEE 04060867 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-01-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-01-27 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-01-27 |
Time |
09:48 |
Sent To |
|
|
Notes |
2005-01-27 00:00:00 | SEE 04060867 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-11-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-11-19 |
Time |
10:14 |
Rev Time |
4.00 |
Received By |
shill |
Date |
2004-11-18 |
Time |
10:02 |
Sent To |
|
|
Notes |
2004-11-19 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2.)SEPARATE PERMITS REQUIRED FOR | | TRADES. | | | | 3.)SIGN THE OWNER/AGENT LINE OF | | THE ENERGY CALC. | | | | 4.)IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY.THE PLANS MUST BE | | STAMPED AND THE RECEIPT ATTACHED TO THE | | APPLICATION.233-5025 | | | | 5.)SEE PREVIOUS LIST, ITEM #14. | | PROVIDE A SURVEY FOR THIS PROPERTY. | | | | 6.)THE PLANS AND ENERGY CALCS SHOW | | THE COMMON WALL (REFERRED TO AS AN | | ADJACENT WALL, LINE 9B) AS HAVING AN R | | VALUE OF 8.4.YOU CANNOT INCLUDE | | INSULATION IN ANOTHER UNIT.REVISE TO | | REFER TO CORRECT WALL TYPE (COMMON) AND | | R VALUE (4.2). | | | | 7.)THE WALL SEPARATING THE TWO UNITS | | IS TO BE CONTINUOUS THROUGH THE FRONT | | PORCH.FBC704.4.2. (NEW COMMENT; NOT | | ON | | PREVIOUS LIST.) | | | | 8.)SEE PREVIOUS LIST, ITEM #32, | | WINDOW BUCK TO GIVE FULL SUPPORT OF THE | | WINDOW, FBC1707.4.4.2 (A7). | | | | 11.)SEE PREVIOUS LIST, ITEM #50, | | FOOTING CANNOT ENCROACH PROPERTY LINE, | | DETAILS B-A4, 1-A5, ANY OTHER | | APPLICABLE | | DETAILS. | | | | 12.)S0.1, ITEM #4, DECLARES THIS | | BUILDING AS A SIMPLE DIAPHRAGM. | | FBC1606.1.5, THE MEAN ROOF HEIGHT | | (>34') CANNOT EXCEED THE LEAST | | HORIZONTAL DIMENSION (33'), A3 | | ELEVATIONS.FOR COMPONENTS AND | | CLADDING, SAYS "SEE PLAN"; WHERE? | | | | 13.)THE 2 HR TENANT SEPARATION WALL | | IS | | TO MAINTAIN THE STRUCTURAL INTEGRITY | | AND | | FIRE RESISTANCE INDEPENDENT OF THE UNIT | | ON THE OPPOSITE SIDE OF THE WALL, | | FBC704.4.2.DETAIL 9-S2.2 SHOWS A | | REINFORCED CONCRETE TOPPING WHICH ENDS | | AT THE TENANT SEPARATION WALL | | (ACCEPTABLE).DETAIL 2-A5 SHOWS THIS | | TOPPING AS CONTINUOUS THROUGH THE WALL. | | DETAILS SHOULD BE CONSISTENT.IF | | DETAIL | | 2-A5 IS USED, WHERE DOES THE | | REINFORCEMENT FOR THE CONCRETE TOPPING | | END? | | | | 14.)16-S2.3 (???APPEARS TO BE 2.3, | | BUT | | THE SHEET NUMBER ON THE PLAN IS NOT | | CLEAR) SHOWS A WOOD POST, WOOD BEAM FOR | | THE FRONT PORCH.B-A4 SHOWS A TS | | COLUMN | | W/STUCCO, WOOD BEAM.HOW DOES THIS | | COMPLY WITH THE 1HR PROTECTED | | REQUIREMENT OF TABLE 600 FOR COLUMNS | | AND | | BEAMS?ALSO APPLIES TO 4-S2.3 | | | | 15.)PLANS REFER TO FIRE RESISTANT | | CALCS BY HOLLOW CORE ENGINEER; THESE | | WERE NOT IN THE PACKAGE, | | FBC709.2.2.1.2. | | | | 16.)STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED FOR ALL CONNECTORS, INCLUDING | | THE ANGLE FOR THE FLOORS, FAC9B-72. | | SEE | | WWW.FLORIDABUILDING.ORG, PRODUCT | | APPROVAL, FOR MORE INFORMATION. | | | | 17.)FBC1007.3.1(1), SUM OF TWO RISERS | | AND A TREAD TO BE 24-25" (ENTRY | | VESTIBULE, A2). | | | | 18.)SEE 04060897 FOR OTHER COMMENTS | | APPLICABLE TO THIS BUILDING. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-07-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-07-23 |
Time |
15:57 |
Rev Time |
3.00 |
Received By |
shill |
Date |
2004-07-23 |
Time |
15:57 |
Sent To |
|
|
Notes |
2004-07-23 00:00:00 | SEE 04060887 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-10-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-10-28 |
Time |
06:29 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-10-28 |
Time |
06:29 |
Sent To |
|
|
Notes |
2004-10-28 00:00:00 | NOTED 2002 NEC | | 210.52 BEDRM |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-06-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-24 |
Time |
11:07 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2004-06-24 |
Time |
11:07 |
Sent To |
|
|
Notes |
2004-06-24 00:00:00 | *********** UNSAT *************** | | BLDG #8 | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | PLANS AND CORRELATE WITH THE SUBMITTED | | PANEL SCHEDULE. | | | | 2)NOTE: PLEASE SEE FS 471.023 AND FAC | | 61G15-23.002. PLEASE INCLUDE REQUIRED | | LICENSE #'S ON TITLE BLOCK. | | PLEASE SEE FIRM AS SHOWN ON PLAN IS | | SHOWN AS LICENSE "CLOSED" ON STATE | | DBPR. PLEASE SEE PRINT OUT ATTACHED. | | PLEASE SEE # WAS NOT ON TITLE BLOCK. | | PLEASE ALSO SEE THIS IS REQUIRED ON | | ALL SHEETS AND FOR ALL TRADES WHEATHER | | OR NOT COMMENT IS MADE BY OTHER REVIEWER | | -S. | | | | 3)NOTE: PLEASE SHOW/ INDICATE A/C CU | | DISC PER 440.11 | | | | 4)NOTE: PLEASE SEE 410.8 FOR FIXTURE | | TYPE AND CLEARENCE FOR MASTER CLOSET. | | DOES NOTE SEEM TO MEET 410.8 | | | | 5)NOTE: PLEASE SEE OCP SHOWN FOR AHU | | IS MUCH LARGER THAN OCP FOR CU, YET | | LOAD CALCS SHOW CU LOAD?? | | PLEASE CORRELATE WITH MECH PLANS. | | | | 6)NOTE: PLEASE SEE MISPRINT FOR 210.12 | | ON E-8 | | | | 7)NOTE: PLEASE SEE NFPA-72FOR SD | | LOCATIONS. 3' FROM BATHS/KITCHENS AND | | 20' FROM COOKING APPLIANCES. W/ EXCEPT- | | -IONS. | | | | PLEASE SEE COMMENTS FROM OTHER REVIEWERS | | AS THEY MAY HAVE AN AFFECT ON ELECTRICAL | | PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
N |
Date |
2004-12-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-12-10 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2004-12-10 |
Time |
15:12 |
Sent To |
|
|
Notes |
2004-12-10 00:00:00 | LESS THAN 3 UNITS, NO FIRE REVIEW | | REQUIRED |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2004-06-24 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-06-24 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-06-24 |
Time |
12:03 |
Sent To |
|
|
Notes |
2004-06-24 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | TO, DURING AND AFTER CONSTRUCTION. | | | | 2) BUILDING ADDRESSES REQUIRED. | | | | 3) PRESCRIPTIVE STRENGTH REQUIREMENTS | | SHALL BE SHOWN ON PLANS FOR ALL | | HANDRAILS AND GUARDRAILS. | | | | 4) IS THE DOOR BETWEEN THE GARAGE AND | | THE STAIRS RATED. NO RATING SHOWN ON | | DOOR SCHEDULE. | | | | 5) SMOKE DETECTORS SHALL BE PLACED A | | MINIMUM OF THREE FEET FROM AIR | | CONDITIONER DIFFUSERS. | | | | 6) NO FIRE SPRINKLER DRAWINGS PROVIDED | | WITH PLANS. PAGE A.1 INDICATES THAT | | THE BUILDING WILL BE FIRE SPRINKLER | | PROTECTED. | | | | 7) NO INFORMATION PROVIDED REGARDING | | MONITORING OF THE FIRE SPRINKLER | | SYSTEM. | | | | 8) SITE PLAN DOES NOT DISPLAY ANY | | FIRE HYDRANTS. | | | | 9) NO MENTION OF ANY FIRE EXTINGUISHERS. | | | | COURTESY REVIEW PERFORMED. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-09-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-12 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-12 |
Time |
08:58 |
Sent To |
B |
|
Notes |
2005-09-12 00:00:00 | TO "SHILL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-03-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-21 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-21 |
Time |
10:00 |
Sent To |
B |
|
Notes |
2005-03-21 00:00:00 | TO "SHILL" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-03-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-01 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-01 |
Time |
08:58 |
Sent To |
|
|
Notes |
2005-03-01 00:00:00 | TO "COMM" BD#36/"COMM" RACK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-06 |
Time |
13:33 |
Sent To |
|
|
Notes |
2005-01-06 00:00:00 | TO "COMM BD#19/RESUB. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-10-14 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-14 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-14 |
Time |
11:08 |
Sent To |
|
|
Notes |
2004-10-14 00:00:00 | TO COMM BD#21/PLANS ON RACK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-07-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-07-23 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2004-06-18 |
Time |
11:07 |
Sent To |
|
|
Notes |
2004-06-18 00:00:00 | TO COMM BD#24 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2005-10-18 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-10-18 |
Time |
16:33 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2005-10-18 |
Time |
16:33 |
Sent To |
|
|
Notes |
2005-10-18 00:00:00 | MECH.REV. PLANS AND E. CAL. . |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2004-12-01 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-12-01 |
Time |
17:10 |
Rev Time |
0.10 |
Received By |
pkrauss |
Date |
2004-12-01 |
Time |
17:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2004-11-01 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-11-01 |
Time |
09:07 |
Rev Time |
2.00 |
Received By |
pkrauss |
Date |
2004-11-01 |
Time |
07:25 |
Sent To |
|
|
Notes |
2004-11-01 00:00:00 | DENIED:BUILDING 8 UNIT 31 | | "BORDEAUX/END UNT" | | COMMENTS #2 & 3 FROM REVEIW DATED | | 7-20-04 WERE NOT ADDRESSED: | | | | 2.RETURN AIR JUMPER FROM THE MASTER | | BEDROOM IS NOT SIZED PROPERLY.A | | MINIMUM OF 16" IS REQUIRED FOR | | COMPLIANCE WITH 2001 FBC(M) 601.4 | | EXCEPTION #1 & 3. | | | | 3.PLEASE CLARIFY RATING BETWEEN THE | | GARAGE AND THE DEN.PLAN M-5 INDICATES | | DUCT PENETRATING THIS WALL.PROVIDE | | DETAIL OF THE SEPARATION WALL/CEILING | | ASSEMBLY FOR THIS PENETRATION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS @ (561)805-6719 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-07-20 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-07-20 |
Time |
07:01 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2004-07-20 |
Time |
06:58 |
Sent To |
|
|
Notes |
2004-07-20 00:00:00 | DENIED:"BORDEAUX MODEL" END-UNIT | | 1.PLEASE NOTE, PER 2001 FBC(M) 104.2.1 | | EACH PERMIT APPLICATION REQUIRES 2 | | COPIES OF PLANS AND SPECIFICATIONS. | | PLEASE PROVIDE ADDITIONAL COPIES. | | | | 2.RETURN AIR JUMPERS FROM THE MASTER | | BEDROOM IS NOT SIZED PROPERLY.PER THE | | REVISED 2001 FBC(M) 601.4 EXCEPTION #1; | | TRANSFER DUCTS SHALL BE A MINIMUM OF 1 | | 1/2 TIMES THE SQUARE INCHES OF THE | | SUPPLY AIR TO THAT SPACE.EXCEPTION #3; | | ALL AIR INTO THE MASTER SUITE TO BE | | INCLUDED.SEE THE ATTACHED SCHEDULE FOR | | PROPER SIZING FOR THE RETURN AIR JUMPERS | | | | 3.PLEASE CLARIFY THE RATING OF THE | | SEPARATION WALL BETWEEN GARAGE AND THE | | RESIDENCE. | | | | 4.PROVIDE OUTSIDE AIR CALCUALTIONS PER | | 2001 FBC(M) 402.2, 402.2.1 OR 403.3. | | | | 5.AUXILIARY DRAIN PAN WITH OVERFLOW | | PROTECTION REQUIRED PER 2001 FBC(M) | | 307.2.3. | | | | 6.PLANS ARE TO BE SIGNED AND DATED BY | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | THE HVAC SYSTEM IN ACCORDANCE WITH THE | | FLORIDA STATUTES AND THE FLORIDA | | ADMINISTRATIVE CODE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-01-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-01-31 |
Time |
13:57 |
Rev Time |
0.54 |
Received By |
kstevens |
Date |
2005-01-31 |
Time |
13:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-07-19 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-07-19 |
Time |
14:54 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2004-07-19 |
Time |
14:54 |
Sent To |
|
|
Notes |
2004-07-19 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1) SHT P.4 TUB IN BATH #2 THIRD FLOOR IS | | NOT VENTED. SECTION 901.2.1 | | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | SHEET. IF PRACTICING THROUGH A DULY | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | THEIR NAME AND LICENSE NUMBER, AS WELL | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | AUTHORIZATION NUMBER OF THE ENGINEERING | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | WILL SATISFY THIS REQUIREMENT. FAC | | 61G15-23.002(2) - FS 471.025 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2005-04-05 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2005-04-05 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2005-04-05 |
Time |
09:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2004-11-01 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-06-30 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-06-30 |
Time |
11:14 |
Sent To |
|
|
Notes |
2004-06-30 00:00:00 | DENIED, NEED TO PROVIDE PLAT WITH 41 | | LOTS WITH ENGINEERING PLANS (2 SETS). | | NEED TO PROVIDE LANDSCAPE PLANS. CALL | | ERIC SCHNEIDER, SENIOR PLANNER AT 659- | | 8031 FOR ANY QUESTIONS. |
|
|