Plan Review Stops For Permit 04060563 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-07-26 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-07-26 |
Time |
09:19 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2004-07-26 |
Time |
09:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-07-01 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-07-01 |
Time |
14:30 |
Rev Time |
1.66 |
Received By |
alange |
Date |
2004-07-01 |
Time |
14:29 |
Sent To |
|
|
Notes |
2004-07-01 00:00:00 | DENIED | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY | | COURTHOUSEAND A COPY SUBMITTED TO THIS | | OFFICE | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | 2.PRINTED NAME OF THE ARCHITECT IS | | REQUIRED ON THE TITLE BLOCK OF ALL | | PAGES.FAC 61G1-16.004(6) & FS 481.2055 | | | | 3.DOOR #6 NEEDS 18" CLEAR AT THE | | LATCHED SIDE OF THE DOOR.SHOW ON PLANS | | | | 4.SAFTEY GLAZING REQUIRED IN STORE | | FRONT WINDOWS PLEASE SHOW ON PLAN. | | FBC2405.2.1 | | | | 5.KITCHEN SINK SHALL COMPLY WITH | | FBC 11.4.24 | | | | 6.DOOR #9 NOT DRAWN TO SCALE OF 36" | | | | ANY QUESTIONS CALL ME. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
N |
Date |
2005-02-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-02-23 |
Time |
06:35 |
Rev Time |
0.10 |
Received By |
dpalmer |
Date |
2005-02-23 |
Time |
06:35 |
Sent To |
|
|
Notes |
2005-02-23 00:00:00 | REV TO FA SHEETS NOT APPLICABLE TO ELEC | | REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-07-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-07-23 |
Time |
08:39 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-07-23 |
Time |
08:39 |
Sent To |
|
|
Notes |
2004-07-23 00:00:00 | REDLINED PLANS. | | | | EM/EXT LTS TO BE CIRCUITED PER 700.12E | | W/LOCAL LT BRANCH CIRCUIT. | | MAY NOT BE ON SEPARATE CIRCUIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-07-01 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2004-07-01 |
Time |
15:00 |
Rev Time |
1.30 |
Received By |
jleahy |
Date |
2004-06-15 |
Time |
13:54 |
Sent To |
|
|
Notes |
2004-06-15 00:00:00 | LOAD CALCULATION TO ALSO BE DONE ON | | SERVICE. | | | | LOAD CALCULATIONS IS OK BUT WHEN THE | | NUMBER OF OUTLETS IS KNOWN THEN 180 VA | | EACH IS USED THEN 220.13 | | | | RISER SHOWS EAST PANEL TO BE 100A FED | | BY 200A MAIN! | | | | AHU CLOSET ON WEST SIDE NEEDS LIGHT AND | | OUTLET. | | | | NEDD TO SHOW BRASNCH CIRCUIT NUMBERS ON | | THE PLANS FOR THE OUTLETS AND LIGHTS. | | | | PANEL SCHEDULES ARE IDENTICAL SPACES | | ARE OT!!!!! | | | | PAGE E-2 SHOW A SATELITE OUTLET OUTSIDE! | | | | ANY QUESTIONS CALL JAKE LEAHY 805-6740 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-07-28 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-07-28 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-07-28 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2004-06-16 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2004-06-16 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2004-06-16 |
Time |
13:17 |
Sent To |
|
|
Notes |
2004-06-16 00:00:00 | *************DENIED********************* | | 1) WHAT ARE THE WALLS AND CEILINGS | | INTERIOR FINISH CLASSIFICATION? CLASS "A | | "B" OR "C". | | | | 2) IT APPEARS THAT ADDITIONAL EXIT SIGN | | AND EMERGENCY LIGHT ARE NEEDED FOR THE | | CORRIDOR LEADING FROM OFFICE #4 TO THE | | RECEPTION AREA. | | | | 3) WILL THESE ALTERATIONS AFFECT FIRE | | SPRINKLER COVERAGE AND FIRE ALARM SYSTEM | | | | 4) SEPARATE PLANS AND PERMIT APPLICATION | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | ALARM SYSTEM REMODEL. | | | | NATE MCCRAY, CAPTAIN | | 835-2910 OR 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-03-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-03 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-03 |
Time |
15:32 |
Sent To |
E |
|
Notes |
2005-03-03 00:00:00 | TO DPALMER DESK/REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-02-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-18 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-18 |
Time |
16:47 |
Sent To |
|
|
Notes |
2005-02-18 00:00:00 | TO "COMM" BD#5 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-08-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-17 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-17 |
Time |
15:57 |
Sent To |
P |
|
Notes |
2004-08-17 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-07-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-22 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-22 |
Time |
08:22 |
Sent To |
|
|
Notes |
2004-07-22 00:00:00 | TO COMM BD#23 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-07-01 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-07-01 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2004-06-14 |
Time |
14:28 |
Sent To |
|
|
Notes |
2004-06-14 00:00:00 | TO COMM BD #16 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-07-31 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2004-07-31 |
Time |
10:57 |
Rev Time |
0.75 |
Received By |
hmoser |
Date |
2004-07-31 |
Time |
10:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-07-31 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-06-30 |
Time |
16:54 |
Rev Time |
1.00 |
Received By |
hmoser |
Date |
2004-06-30 |
Time |
16:41 |
Sent To |
|
|
Notes |
2004-07-01 00:00:00 | DENIED: | | 1.PLEASE PROVIDE OUTSIDE AIR | | CALCULATIONS PER 2001 FBC(M) 403.3. | | | | 2.INDCIATE OUTSIDE AIR INTAKE, DUCT | | SIZE, MATERIAL & LAYOUT. | | | | 3.DUCT SMOKE DETECTORS IN SYSTEMS THAT | | HAVE THE DESIGN CAPACITY GREATER THAN | | 2,000 CFM.2001 FBCF(M) 606.2.1. | | | | 4.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | SHALL HAVE NOTIFICATION TO ALARM/STROBE | | IN NORMALLY OCCUPIED AREAS PER NFPA 90A | | 6.4.4.3. | | | | 5.PLEASE INDICATE CONDENSATE | | TERMINATION SND LINE SIZE. | | | | 6.AUXILIARY DRAIN PAN WITH OVERFLOW | | PROTECTION REQUIRED PER 2001 FBC(M) | | 307.2.3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2004-08-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-08-23 |
Time |
13:36 |
Rev Time |
0.60 |
Received By |
kstevens |
Date |
2004-08-23 |
Time |
13:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2004-07-31 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-17 |
Time |
15:57 |
Rev Time |
2.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2004-07-31 00:00:00 | PLUMBING PLAN REVIEW, DENIED FBC 2001 | | PREVIOUS NOTES DATED 06-23-04 | | COMMENT #7 WATER RISER DIAGRAM, | | IS REQUIRED SEC 104.3.1.1 | | WHA TO BE LOCATED WITHIN THE WATER | | RISER DIAGRAM. | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-06-23 |
Time |
12:29 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2004-06-23 |
Time |
12:29 |
Sent To |
|
|
Notes |
2004-06-23 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1) ALL SHEETS A SPACE FOR THE PRINTED | | NAME OF THE PERSON SEALING THE PLANS IS | | REQUIRED. FAC 61G1-16.004(6) & FS 481. | | 2055. | | 2) SHT A1 SHOW CLEAR FLOOR SPACE FOR ALL | | ACCESSIBLE FIXTURES. W/C'S 11-4.16.2, | | LAV'S 11-4.19.3, & KIT. SINK 11-4.24.5. | | 3) SHT A1 DOORS SHALL NOT SWING INTO THE | | CLEAR FLOOR SPACE REQUIRED FOR ANY FIX- | | TURE. 11-4.22.2. | | 4) SHT A1 A DRINKING FOUNTAIN IS REQUIR- | | ED. TABLE 403.1. (SEE SECTION 410.1) | | 5) SHT A2 DETAIL D, SHOW SINK HEIGHT AT | | 34" MAX. 11-4.24.2, KNEE CLEARANCE 11-4. | | 24.3, DEPTH OF SINK 11-4.24.4 AND EX- | | POSED PIPES AND SURFACES 11-4.24.6. | | 6) SHT A2 DETAIL "B" SHOW EXPOSED PIPES | | AND SURFACES 11-4.19.4. | | 7) SHT P1 WATER RISER DIAGRAM REQUIRED | | SECTION 104.3.1.1. SHOW WATER HAMMER | | ARRESTORS WHERE REQUIRED BY SECTION | | 604.9. W.H.A'S SHALL BE LOCATED NEAR THE | | FIXTURES, NOT IN THE CEILING PER PDI-WH | | 201. | | 8) SHT P1 GENERAL PLUMBING NOTES #17, | | AIR CHAMBERS ARE NOT APPROVED. DELETE | | FROM REFERENCE. SECTION 604.9 & SECTION | | 104.2.1 | | 9) ALL SHEETS, PRINTED NAME OF THE ARCH- | | ITECT IS REQUIRED ON TITLE BLOCK. FAC | | 61G1-16.004(6) & FS 481.2055 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|