Plan Review Details - Permit 04060268
Plan Review Stops For Permit 04060268
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-07-29 Cont ID  
Sent By alange Date 2004-07-29 Time 11:24 Rev Time 0.66
Received By alange Date 2004-07-29 Time 11:24 Sent To M
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-06-22 Cont ID  
Sent By pkrauss Date 2004-06-21 Time 11:42 Rev Time 1.50
Received By alange Date 2004-06-22 Time 14:11 Sent To  
Notes
2004-06-22 00:00:00DENIED
  
 1.FBC 3401.7.1.2.1WHEN ADDITIONS
 INCREASING THE FLOOR AREA OF AN EXISTING
 BUILDING IS INCREASED BY 25%, THE
 EXISTING BUILDING SHALL COMPLY WITH
 THE FOLLOWING.
 1.GFCI OUTLETS SHALL BE INSTALLED
 WHERE REQUIRED BY THE CODE.
 2.SMOKE DETECTORS SHALL BE
 INSTALLED WHERE REQUIRED BY THE CODE.
 SHOW ON PLANS THE LOCATION THESE CHANGES
  
 2.BASED UPON SBCCI BUILDING VALUATION
 DATA THE VALUE HAS BEEN CHANGED TO
 $27,705.ADDITIONAL PERMIT FEES ARE
 DUE.
 PERMIT FEES $554.10
 RADON FEE$5.04
  
 ANY QUESTIONS CALL ME
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-06-14 Cont ID  
Sent By csiegber Date 2004-06-09 Time 10:38 Rev Time 0.50
Received By btrobaug Date 2004-06-14 Time 07:43 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-19 Cont ID  
Sent By csiegber Date 2004-07-19 Time 09:39 Rev Time 0.00
Received By csiegber Date 2004-07-19 Time 09:39 Sent To M
Notes
2004-07-19 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-09 Cont ID  
Sent By csiegber Date 2004-06-09 Time 10:38 Rev Time 0.00
Received By csiegber Date 2004-06-09 Time 10:40 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-06-08 Cont ID  
Sent By mmclean Date 2004-06-08 Time 16:39 Rev Time 0.00
Received By csiegber Date 2004-06-08 Time 10:45 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-07-29 Cont ID  
Sent By hmoser Date 2004-07-29 Time 17:48 Rev Time 0.50
Received By hmoser Date 2004-07-29 Time 17:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-06-21 Cont ID  
Sent By alange Date 2004-07-29 Time 11:24 Rev Time 0.35
Received By pkrauss Date 2004-06-21 Time 11:39 Sent To B
Notes
2004-06-21 00:00:00DENIED:
 RETURN AIR REQUIRED PER 2001 FBC(M)
 601.4.PLEASE PROVIDE DUCT/GRILLE
 SIZE & LOCATION.
  
 PLEASE INDICATE THE DUCT SIZE OF THE
 SUPPLY DUCT FROM THE DISTRIBUTION BOX
 BACK TO THE EXISTING SYSTEM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-06-19 Cont ID  
Sent By btrobaug Date 2004-06-14 Time 10:55 Rev Time 0.50
Received By kstevens Date 2004-06-19 Time 13:04 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-06-08 Cont ID  
Sent By csiegber Date 2004-06-08 Time 10:53 Rev Time 0.00
Received By mmclean Date 2004-06-08 Time 16:39 Sent To I
Notes
***NONE***