Plan Review Stops For Permit 04060201 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-09-22 |
Time |
07:26 |
Rev Time |
0.75 |
Received By |
mjacobs |
Date |
2005-09-22 |
Time |
07:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-07-30 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-07-30 |
Time |
10:51 |
Rev Time |
0.50 |
Received By |
mjacobs |
Date |
2004-07-30 |
Time |
10:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-23 |
Time |
10:32 |
Rev Time |
2.00 |
Received By |
mjacobs |
Date |
2004-06-23 |
Time |
10:47 |
Sent To |
|
|
Notes |
2004-06-23 00:00:00 | BUILDING PLAN REVIEW | | PERMIT:04060201 | | ADD:201 S. NARCISSUS AV #403 | | CONT:PAUL NEWMAN | | TEL: (561)719-4248 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | 2) SHEET A.O IN YOUR NOTES STATES TYPE | | OF BLDG. AS TYPE III. PLEASE SEE FBC | | SEC.311.2 | | | | 3) NOTO: FAIR HOUSING ANSI A117 CHANGES | | OF FLOOR LEVELS SEE SEC. 303.3 WHICH IS | | 1/4" ALLOWED. SEE SEC.303.4 BEVELS USED | | ON THRESHOLDS MAX HEIGHT IS 1/2". | | | | | | 4) FLOOR: THE THICKNESS OF PLYWOOD SEE | | FBC CH 8 SEC.803.7.2. TYPE II | | CONSTRUCTION INSULATING BOARD SHOULD NOT | | BE MORE THAN 1/2" | | | | ) PLEASE SUBMIT ADDITIONAL DETAILS | | TO SHOW ATTATCHMENT AND FASTENING OF | | MATERIALS TO FLOOR AND CEILING DECK. | | | | 6) SUBMIT TYPE OF BACKING TO BE USED IN | | ALL WALLS. SEE SHEET A.8 DETAIL#3 | | 609.2.1 FIRE RETARDENT TREATED WOOD. | | | | | | 7) TABLE 803.3 MINIMUM INTERIOR FINISH | | CLASSIFICATION; PROVIDE INFORMATION | | BASED ON INTERIOR FINISH REQUIREMENTS | | BASED ON OCCUPANCY. ALSO SEE SEC.803.4 | | | | | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | | | MYRON JACOBS | | TEL: (561)805-6726 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-22 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-09-22 |
Time |
08:01 |
Sent To |
|
|
Notes |
2005-09-22 00:00:00 | RE-STAMP |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-07-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-07-27 |
Time |
14:31 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-07-27 |
Time |
14:31 |
Sent To |
|
|
Notes |
2004-07-27 00:00:00 | NO CHANGES, SAME SHEETS BROUGHT BACK IN. | | RE-SIGNED. 7/27/04 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-06-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-10 |
Time |
13:17 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-06-10 |
Time |
13:17 |
Sent To |
|
|
Notes |
2004-06-10 00:00:00 | **** REDLINED *** | | | | TO MEET 2002 NEC 210.12 FOR ARC FAULT | | PROTECTION. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-07-29 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-07-29 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-07-29 |
Time |
13:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2004-06-07 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2004-06-07 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2004-06-07 |
Time |
11:17 |
Sent To |
|
|
Notes |
2004-06-07 00:00:00 | ***************DENIED******************* | | 1) HOW WILL THE FIRE SPRINKLER COVERAGE | | BE EFFECTED BY THE INTERIOR REMODEL. | | | | 2) THE INTERIOR FINISH CLASSIFICATION | | FOR WALLS AND CEILINGS SHALL BE EITHER | | CLASS "A","B" OR "C". | | | | 3) SEPARATE PLANS AND PERMIT APPLICATION | | ARE REQUIRED FOR FIRE SPRINKLER REMODEL. | | | | NATE MCCRAY, CAPTAIN | | 835-2910 OR 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-09-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-21 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-21 |
Time |
14:49 |
Sent To |
B |
|
Notes |
2005-09-21 00:00:00 | TO "MJACOBS" DESK/RESTAMP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-07-23 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-07-23 |
Time |
12:30 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2004-07-23 |
Time |
12:30 |
Sent To |
|
|
Notes |
2004-07-27 00:00:00 | COMMERCIAL BOARD # 48 LS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-06-23 |
Time |
12:30 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2004-06-04 |
Time |
13:22 |
Sent To |
|
|
Notes |
2004-06-04 00:00:00 | TO COMM BD#18 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2004-06-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-06-18 |
Time |
08:57 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2004-06-18 |
Time |
08:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2004-08-07 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-08-07 |
Time |
16:52 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-08-07 |
Time |
16:52 |
Sent To |
|
|
Notes |
|
|