Plan Review Stops For Permit 04050853 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-07-12 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-07-12 |
Time |
09:40 |
Rev Time |
1.00 |
Received By |
lsmith |
Date |
2004-07-08 |
Time |
09:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-06-17 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-17 |
Time |
14:08 |
Rev Time |
1.00 |
Received By |
mjacobs |
Date |
2004-06-17 |
Time |
14:08 |
Sent To |
PC |
|
Notes |
2004-06-17 00:00:00 | BUILDING PLAN REVIEW | | PERMIT:04050853 | | ADD:1450 CENTREPARK BLVD SUITE 325 | | CONT:BURKARDT CONSTRUCTION, INC | | TEL: (561)659-1400 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | 1ST REVIEW | | ACTION: DENIED | | | | 1)1004.1.4 WHERE 2 OR MORE EXITS OR | | EXIT ACCESS DOORS ARE REQUIED, AT LEAST | | 2 OF THE EXIT OR EXIT ACCESS DOORS SHALL | | BE PLACED A DISTANCE APART EQUAL TO NOT | | LESS THAN 1/2 OF THE LENGTH OF THE MAX- | | IMUM OVERALL DIAGONAL DIMENSION OF THE | | BUILDING OR AREA TO BE SERVED. | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | ITIONS, EXIT ENCLOSURES, AND FIRE | | RATED WALLS REQUIRED TO HAVE PROTECTED | | OPENINGS SHALL BE EFFECTIVELY AND | | PERMANETLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | CEILING CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | PROTECT ALL OPENINGS". | | | | 3)11-4.24.2 HEIGHT. SINKS SHALL BE | | MOUNTED WITH THE COUNTER OR RIM NO | | HIGHER THAN 34" ABOVE THE FINISH FLOOR. | | | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | MYRON JACOBS | | TEL: (561)805-6726 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-23 |
Time |
07:31 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-06-22 |
Time |
21:15 |
Sent To |
|
|
Notes |
2004-06-23 00:00:00 | **************************************** | | | | CONTRACTOR IS TO COME DOWN AND REMOVE | | ALL OLD/VOIDED SHEETS AND INSERT NEW | | SHEETS INTO COMPLETE SETS FOR REVIEW | | AND STAMPING. | | NEW SHEETS NOT IN SETS. | | **************************************** |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-05-25 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-21 |
Time |
15:07 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2004-05-25 |
Time |
13:07 |
Sent To |
|
|
Notes |
2004-05-25 00:00:00 | ************ UNSAT **************** | | | | 1)NOTE: PLEASE SEE CERTIFICATE OF AUTHO- | | -RIZATION # PRINTTED ON TITLE BLOCK | | BELONGS TO ROY F JOHNS & ASSOCIATES. | | PLEASE SEE COPY OF PRINT OUT FROM DBPR. | | THIS IS REQUIRED TO BE CORRECTED ON | | ALL SHEETS WHEATHER OR NOT COMMENT IS | | MADE FROM OTHER REVIEWERS. | | | | 2)NOTE: PLEASE SEE FS 471.025/ FAC 61G15 | | -23.002. PLEASE PROVIDE A FULL SIGNATURE | | CONTAINING A MIN OF FIRST AND LAST NAME. | | INITIALS ARE NOT PERMITTED. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-06-23 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-06-23 |
Time |
13:49 |
Sent To |
|
|
Notes |
2004-06-23 00:00:00 | ELECTRONIC LOCKS TO COMPLY WITH FIRE | | CODE REQUIREMENTS. | | | | MIKE CARSILLO, ASSSTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2004-05-20 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-05-20 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-05-20 |
Time |
10:49 |
Sent To |
|
|
Notes |
2004-05-20 00:00:00 | 1) HOW DOES THE ELECTRIC STRIKES ON | | DOORS 305 AND 312 AFFECT EXITING. | | ANY LOCKING DEVICES INSTALLED ON | | EGRESS DOORS SHALL COMPLY WITH | | ALL OF THE REQUIREMENTS OF THE LIFE | | SAFETY CODE, 2000 EDITION, CHAPTER 7. | | | | 2) SEPARATE PERMITS REQUIRED FOR ANY | | REQUIRED REMODEL OF THE FIRE SPRINKLER | | OR FIRE ALARM SYSTEM. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-06-21 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-21 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-06-21 |
Time |
15:07 |
Sent To |
|
|
Notes |
2004-06-21 00:00:00 | TO COMM BD#13 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-05-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-20 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-20 |
Time |
08:37 |
Sent To |
|
|
Notes |
2004-05-20 00:00:00 | TO COMM BD#34 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-07-02 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-07-02 |
Time |
09:02 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2004-07-02 |
Time |
09:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-06-09 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-06-09 |
Time |
07:04 |
Rev Time |
0.50 |
Received By |
pkrauss |
Date |
2004-06-09 |
Time |
07:02 |
Sent To |
|
|
Notes |
2004-06-09 00:00:00 | DENIED: | | 1.CERTIFICATE OF AUTHORIZATION # ON | | THE TITLE BLOCK IS NOT CORRECT ACCORDING | | TO DBPR.PLEASE CORRECT. | | | | 2.PLAN SHEET M2.1 INDICATES EXHAUST | | AIR FROM EF-1 DISCHARGING INTO THE | | PLENUM.PER 2001 FBC(M) 501.3, EVERY | | MECHANICAL EXHAUST SYSTEM SHALL BE | | DISCHARGED TO THE OUTDOORS WHERE IT | | CANNOT BE DRAWN IN BY A VENTILATING | | SYSTEM. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-07-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-07-09 |
Time |
17:48 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2004-07-09 |
Time |
17:48 |
Sent To |
|
|
Notes |
2004-07-09 00:00:00 | | | | | | | | | | | PASSED/PROVISO | | | | SECTION 608.3 ALL DEVICES INTENDED TO | | SERVE SOME SPECIAL FUNCTION SUCH AS | | COOLING, AND THAT CONNECT TO THE WATER | | SUPPLY SYSTEM, SHALL BE PROVIDED WITH | | PROTECTION AGAINST BACKFLOW AND CONTAM- | | INATION OF THE WATER SUPPLY. COMMERCIAL | | DRINKING WATER DISPENSERS SHALL BE PRO- | | TECTED AGAINST CONTAMINATION. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Z |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-06-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-06-12 |
Time |
15:58 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-06-12 |
Time |
15:58 |
Sent To |
|
|
Notes |
2004-06-12 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1) SHT A-2 SHOW KNEE CLEARANCE 11-4.24.3 | | DEPTH 11-4.24.4. CLEAR FLOOR SPACE 11-4. | | 24.5, EXPOSED PIPES AND SURFACES 11-4.24 | | .6 ON DETAIL FOR LOUNGE SINK. | | 2) SUBMIT MANUFACTURE SPECIFICATION FOR | | WATER COOLER. FIXTURE, DEVISE OR APPLI- | | ANCE USING WATER FOR ITS PROPER OPERAT- | | ION SHALL BE DIRECTLY OR INDIRECTLY CON- | | NECTED TO THE WATER SUPPLY. SEE SECTIONS | | 301.2, 301.3 & 301.4. | | 3) SEE ELECTRICAL REVIEW CONCERNING THE | | CERTIFICAT OF AUTHROIZATION REQUIRED ON | | TITLE BLOCK OF SIGNED/SEALED PLANS. | | 61G15-23.002 FAC & FS 471.025 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|