Plan Review Stops For Permit 04050413 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-07-20 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-07-20 |
Time |
11:05 |
Rev Time |
0.25 |
Received By |
lsmith |
Date |
2004-07-20 |
Time |
11:05 |
Sent To |
|
|
Notes |
2004-07-20 00:00:00 | ADDING SPA & HEAT PUMP TO EXISTING POOL |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-05-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-07-20 |
Time |
10:02 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2004-05-27 |
Time |
08:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-07-20 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-07-20 |
Time |
10:02 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2004-07-20 |
Time |
09:50 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-05-25 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-07-17 |
Time |
05:20 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2004-05-14 |
Time |
13:27 |
Sent To |
P |
|
Notes |
2004-05-25 00:00:00 | | | PLEASE PROVIDE A CALCULATION | | INCLUDING ALL ADDED LOADS IMPOSED,ALL | | EXISTING LOADS AND THE EXISTING OR | | PROPOSED SERVICE SPECIFICATIONS PER | | 215.15. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-06-29 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-29 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-06-29 |
Time |
11:43 |
Sent To |
P |
|
Notes |
2004-06-29 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-06-04 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-04 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-06-04 |
Time |
13:51 |
Sent To |
P |
|
Notes |
2004-06-04 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-05-13 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-13 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-13 |
Time |
14:12 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-05-12 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-05-13 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-12 |
Time |
09:29 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2004-07-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-07-17 |
Time |
05:20 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-07-17 |
Time |
05:20 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2004-06-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-29 |
Time |
11:43 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2004-06-22 |
Time |
16:07 |
Sent To |
|
|
Notes |
2004-06-22 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 1 | | | | SUBMIT TWO COMPLETE SETS OF PLANS WITH | | ORIGINAL APPLICATION FOR REVIEW. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-05-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-04 |
Time |
13:51 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2004-05-26 |
Time |
16:09 |
Sent To |
|
|
Notes |
2004-05-26 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | FBC-2001 CHAPTER 1 | | | | 1) MORE INFORMATION REQUIRED ON FOUNTAIN | | PIPING DIAGRAM SHOWS 1" PIPE FOR FOUNT- | | AIN. IS THIS AN EXISTING FOUNTAIN? OR | | IS THE FOUNTAIN BEING BUILT AT THIS TIME | | IF NEW FOUNTAIN A DETAIL WILL BE REQUIR- | | ED, AND VALUATION WILL HAVE TO INCLUDE | | THE FOUNTAIN. | | 2) PROPOSAL INDICATES 1-SPA RETURN. THIS | | IS NOT SHOWN ON THE PIPING DIAGRAM. | | PLEASE CLARIFY. | | 3) VENT PIPE FOR SPA MAIN DRAINS IS NOT | | SHOWN ON PIPING DIAGRAM. SHOW ALL PIPING | | 4) EXTERNAL HARTFORD LOOP REQUIRED FOR | | HEAT PUMP TO MAINTAIN WATER RETENTION | | PER 424.2.14.2. INDICATE ON PLANS. | | 5) BACKFLOW PREVENTOR SHALL BE INSTALLED | | PRIOR TO COMMENCING WORK ON SPA. (INDIC- | | ATE IF INSTALLED WITH POOL). | | 6) NEW VALUATION PER SECTION 104.6.5 | | AND MARSHALL AND SWIFT WILL BE $10,137. | | FEES DUE. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2004-07-28 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-07-28 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-07-28 |
Time |
14:52 |
Sent To |
|
|
Notes |
2004-07-28 00:00:00 | SURVEY PROVIDED FOR RESTAMP.NEYITA | | WROTE RECEIPT FOR BALANCE FEE MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2004-07-20 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-07-22 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-07-20 |
Time |
16:09 |
Sent To |
|
|
Notes |
2004-07-22 00:00:00 | NEED TO PROVIDE THE APPROVED SURVEY | | STAMPED BY ZONING OR PROVIDE 2 NEW | | COPY OF SURVEY SHOWING THE SETBACK FOR | | POOL.CALLED CONTR.FILE IN MICHELLE'S | | OFFICE MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-05-13 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-12 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-05-13 |
Time |
10:22 |
Sent To |
I |
|
Notes |
|
|