Plan Review Details - Permit 04050394
Plan Review Stops For Permit 04050394
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-02-08 Cont ID  
Sent By lsmith Date 2005-02-08 Time 10:33 Rev Time 0.50
Received By lsmith Date 2005-02-08 Time 10:33 Sent To  
Notes
2005-02-08 00:00:00BUILDING PLAN REVIW: REVISION
 FLOOR PLAN CHANGES: ELEMINATE BATH #1,
 CHANGE BEDROOM #2 TO SITTING
 ROOM/OFFICE, ENLARGE BEDROOOM # 1 &
 RECONFIGURE CLOSET, RECONFIGURE BATH,
 ADD LINEN CLOSET.
  
 NOTE: FAILED ELECTRIC

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-07-12 Cont ID  
Sent By lsmith Date 2004-07-12 Time 08:15 Rev Time 0.75
Received By lsmith Date 2004-07-12 Time 08:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-06-28 Cont ID  
Sent By jleech Date 2004-07-10 Time 10:53 Rev Time 1.00
Received By lsmith Date 2004-06-08 Time 11:05 Sent To  
Notes
2004-06-08 00:00:00BUILDING PLAN REVIEW FAILED:
  
 1.PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
 A. ROOF MATERIALS (SEE SAMPLE ATTACHED)
 B. EXTERIOR DOORS
 C. WINDOWS
 D. STORM PANELS (NOTE: POMA STORM PANELS
 DO NOT HAVE STATE OF FLORIDA PRODUCT
 APPROVALS.FILL OUT A LOCAL PRODUCT
 APPROVAL APPLICATION (ATTACHED) OR
 SELECT ANOTHER STORM PANEL COMPANY.
 E. STRUCTURAL COMPONENTS (TRUSS STRAPS,
 ETC.
  
 2. FLORIDA ENERGY EFFECIENCY CODE
 HAS TO BE SIGNED BY THE OWNER/AGENT.
  
 3. A UNITY OF TITLE NEEDS TO BE FILED AT
 THE COUNTY CLERKS OFFICE JOINING THE
 THREE LOTS AS ONE.A COPY MUST BE
 SUBMITTED.
  
  
 IF ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUIDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-02-17 Cont ID  
Sent By btrobaug Date 2005-02-17 Time 10:55 Rev Time 0.33
Received By btrobaug Date 2005-02-17 Time 10:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-01-25 Cont ID  
Sent By btrobaug Date 2005-01-25 Time 15:00 Rev Time 0.50
Received By btrobaug Date 2005-01-25 Time 14:43 Sent To P
Notes
2005-01-25 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} WALL COUNTER SPACES. A RECEPTACLE
 OUTLET SHALL BE INSTALLED AT EACH WALL
 COUNTER SPACE THAT IS 300 MM (12 IN.) OR
 WIDER. RECEPTACLE OUTLETS SHALL BE
 INSTALLED SO THAT NO POINT ALONG THE
 WALL LINE IS MORE THAN 600 MM (24 IN.)
 MEASURED HORIZONTALLY FROM A RECEPTACLE
 OUTLET IN THAT SPACE.
  
 2} SMOKE DETECTORS PER 8-1.4.1.6
 NFPA-72.
  
 3} OUTDOOR OUTLETS. FOR A ONE-FAMILY
 DWELLING AND EACH UNIT OF A TWO-FAMILY
 DWELLING THAT IS AT GRADE LEVEL, AT
 LEAST ONE RECEPTACLE OUTLET ACCESSIBLE
 AT GRADE LEVEL AND NOT MORE THAN 2.0 M
 (61/2 FT) ABOVE GRADE SHALL BE INSTALLED
 AT THE FRONT AND BACK OF THE DWELLING.
 SEE 210.8(A)(3).
  
 NONE OF THESE REDLINED ITEMS WERE
 CORRECTED ON THE REVISIONS.PLEASE
 CORRECT SAME AND RESUBMIT FOR REVIEW.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-05-13 Cont ID  
Sent By csiegber Date 2004-05-12 Time 10:17 Rev Time 0.50
Received By btrobaug Date 2004-05-13 Time 07:33 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-09-09 Cont ID  
Sent By adarroug Date 2005-09-09 Time 11:54 Rev Time 0.00
Received By adarroug Date 2005-09-09 Time 11:54 Sent To M
Notes
2005-09-09 00:00:00TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-10 Cont ID  
Sent By adarroug Date 2005-02-10 Time 14:01 Rev Time 0.00
Received By adarroug Date 2005-02-10 Time 14:01 Sent To E
Notes
2005-02-10 00:00:00TO BTROBAUG DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-18 Cont ID  
Sent By mjacobs Date 2005-01-18 Time 10:13 Rev Time 0.00
Received By mjacobs Date 2005-01-18 Time 10:13 Sent To E
Notes
2005-01-18 00:00:00TO "BT" DESK/REV.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-12 Cont ID  
Sent By csiegber Date 2004-05-12 Time 10:15 Rev Time 0.00
Received By csiegber Date 2004-05-12 Time 10:15 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-09-09 Cont ID  
Sent By pkrauss Date 2005-09-09 Time 13:55 Rev Time 0.30
Received By pkrauss Date 2005-09-09 Time 13:55 Sent To  
Notes
2005-09-09 00:00:00AS-BUILT DRAWINGS SUBMITTED WITHOUT FEES
 BEING ASSESSED. FEES OWED

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2005-02-07 Cont ID  
Sent By pkrauss Date 2005-02-07 Time 16:06 Rev Time 0.25
Received By pkrauss Date 2005-02-07 Time 15:56 Sent To B
Notes
2005-02-07 00:00:00NO MECHANICAL SUBMITTED FOR REVISION.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-05-25 Cont ID  
Sent By pschmitz Date 2004-05-16 Time 10:55 Rev Time 0.35
Received By pkrauss Date 2004-05-25 Time 08:29 Sent To B
Notes
2004-05-25 00:00:00PROVISO:
 RETURN AIR FROM BEDROOM #1 SHALL BE A
 MINIMUM OF 11" PER 2001 FBC(M) 601.4
 EXCEPTION #1 & 3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-02-05 Cont ID  
Sent By pschmitz Date 2005-02-05 Time 09:50 Rev Time 0.00
Received By pschmitz Date 2005-02-05 Time 09:50 Sent To M
Notes
2005-02-05 00:00:00DELETE BATH #1

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-07-10 Cont ID  
Sent By btrobaug Date 2005-01-25 Time 15:01 Rev Time 0.50
Received By jleech Date 2004-07-10 Time 10:53 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-05-16 Cont ID  
Sent By btrobaug Date 2004-05-13 Time 08:03 Rev Time 1.50
Received By pschmitz Date   Time   Sent To M
Notes
2004-05-16 00:00:00PLUMBING PLAN REVIEW FBC 2001 DENIED.
 (1) PLUMBING ISOMETRIC, COMPLY WITH SEC
 104.2.1.3 QUALITY OF BUILDING PLANS.
 PLUMBING ISOMETRIC DRAWING, REDO FOR
 CODE COMPLIANCE,CLARITY AND SCALE.
 (2A) BATH ROOM #2 COMPLY WITH SEC 405
 INSTALLATION OF PLUMBING FIXTURES FOR
 PROPER CLEARANCES.
 (2B) SHOWERER COMPARTMENT SEC 417.4
 SHOWER COMPARTMENT SHALL NOT BE LESS
 THAN 30" IN MINIMUM DIMENSION MEASURED
 FROM THE FINISHED INTERIOR DIMENSION.
 (3) KITCHEN SINK, PRO VENTS NOT APPROVED
 END OF COMMENTS,QUESTIONS 561-805-6692

Review Stop Z ZONING
Rev No 2 Status P Date 2004-07-14 Cont ID  
Sent By lsmith Date 2004-07-14 Time 11:11 Rev Time 0.25
Received By lsmith Date 2004-07-14 Time 11:11 Sent To  
Notes
2004-07-14 00:00:00PER SG 7/14/04 LS

Review Stop Z ZONING
Rev No 1 Status F Date 2004-06-08 Cont ID  
Sent By mmclean Date 2004-06-08 Time 11:53 Rev Time 0.00
Received By mmclean Date 2004-06-08 Time 11:53 Sent To B
Notes
2004-06-08 00:00:00DENIED, NEED TO SHOW ADDITION ON SURVEY.
 MUST HAVE 15FT OR 10% OF LOT DEPT WHICH-
 EVER LESS IN REAR OF PROPERTY.PROVIDE
 COPY OF UNITY OF TITLE FOR LOT 220/221/
 222.