Plan Review Details - Permit 04050352
Plan Review Stops For Permit 04050352
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-07-14 Cont ID  
Sent By lsmith Date 2004-07-14 Time 08:20 Rev Time 1.00
Received By lsmith Date 2004-07-14 Time 08:20 Sent To  
Notes
2004-07-14 00:00:00BUILDING PLAN REVIEW: PROVISO
  
 1. SEE NOTES ON FIRST REVIEW FOR
 FLORIDAPRODUCT APPROVALS FOR THE
 FOLLOWING:
 A. WINDOWS
 B. DOORS, SWINGING
 C. GLASS BLOCK
 D. ROOF MATERIALS
 E. STRUCTURAL COMPONENTS (TRUSS ANCHORS
 D. STORM PANELS
  
 2. THE ROOFER MUST APPLY FOR A SEPARATE
 PERMIT.
  
 3. THE STORM PANELS WILL BE UNDER
 SEPARATE PERMIT.NEED TO SUBMIT AN
 INSTALLATION SCHEDULE WITH PERMIT
 APPLICATION.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-06-07 Cont ID  
Sent By jleech Date 2004-07-13 Time 20:02 Rev Time 0.00
Received By lsmith Date 2004-06-07 Time 14:57 Sent To  
Notes
2004-06-07 00:00:00BUILDING PLAN REVIEW FAILED:
  
 1.PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
 A.PGT SWD-101
 B.PGT SH-701 IMPACT
 C. EXTERIOR METAL DOOR
 D. GLASS BLOCK
 E. ROOF MATERIALS
  
 2. SUBMIT 2 COPIES OF ENERGY CODE FORM
 WITH 1 EXTRA COPY OF PAGE 1 TO BE SENT
 TO THE STATE. MUST BE SIGNED BY OWNER/
 AGENT.
  
 3. ADDITIONAL FEES DUE PER SBCCI
 VALUATION TABLE: & RADON FEES: $182.78
  
 4. PLANS MUST BE TAKEN TO PALM BEACH
 COUNTY AND IMPACTMFEESMPAID.THEY WILL
 STAMP THE PLANS & ISSUE A RECEIPT.
 SUBMIT STAMPED PLANS & RECEIPT BEFORE A
 PERMIT CAN BE ISSUED.
  
 5. A NOTICE OF COMMENCEMENT MUST BE
 FILED AT CLERK OF COURT BEFORE A PERMIT
 CAN BE ISSUED.
  
 6. SUBMIT A SURVEY SHOWING THE PROPOSED
 ADDITION WITH FLOOR ELEVATIONS SHOWN.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-03-23 Cont ID  
Sent By dpalmer Date 2005-03-23 Time 09:22 Rev Time 0.25
Received By dpalmer Date 2005-03-23 Time 09:22 Sent To  
Notes
2005-03-23 00:00:00ADDED 100A SUB PANEL TO SERVICE FOR NEW
 ADDTION BRANCH CIRCUITS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-05-13 Cont ID  
Sent By csiegber Date 2004-05-12 Time 17:01 Rev Time 0.50
Received By btrobaug Date 2004-05-13 Time 10:04 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-01 Cont ID  
Sent By csiegber Date 2004-07-01 Time 15:30 Rev Time 0.00
Received By csiegber Date 2004-07-01 Time 15:30 Sent To P
Notes
2004-07-01 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-05-12 Cont ID  
Sent By csiegber Date 2004-05-12 Time 17:01 Rev Time 0.00
Received By csiegber Date 2004-05-12 Time 17:01 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-11 Cont ID  
Sent By mmclean Date 2004-05-12 Time 15:08 Rev Time 0.00
Received By csiegber Date 2004-05-11 Time 08:22 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-05-26 Cont ID  
Sent By kstevens Date 2004-05-26 Time 17:13 Rev Time 0.35
Received By pkrauss Date 2004-05-26 Time 16:33 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-07-13 Cont ID  
Sent By jleech Date 2004-07-13 Time 20:02 Rev Time 0.50
Received By jleech Date 2004-07-13 Time 20:02 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-05-26 Cont ID  
Sent By csiegber Date 2004-07-01 Time 15:30 Rev Time 1.00
Received By kstevens Date 2004-05-26 Time 12:49 Sent To M
Notes
2004-05-26 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SDHT A-2 SANITARY RISER DIAGRAM, THE
 WASH MACHINE IS NOT VENTED, REQUIRES A
 STANDPIPE AND REQUIRES A CLEANOUT 4'
 ABOVE THE FLOOR PER SECTIONS 901.2.1,
 1002.1, 802.4, & 708.10. (SEE RED LINES
 ON RISER DIAGRAM). - SIZE ALL PIPES ON
 RISER PER TABLE 709.1.
 2) THE PERSONAL SIGNATURE OF THE ARCHIT-
 ECT SHALL APPEAR ON ALL ARCHITECTURAL
 DOCUMENTS TO BE FILED FOR PUBLIC RECORD.
 PER DBPR, INITIALS ARE NOT ACCEPTABLE.
 IF THIS YOUR LEAGAL SIGNATURE, A SIGNED,
 SEALED, DATED LETTER WITH TITLE BLOCK
 STATING SUCH WITH A COPY OF LICENSE
 SHOWING SIGNATURE CAN BE SUBMITTED FOR
 OUR FILE. LETTER SHALL BE NOTORIZED.
 FAC 61G1-16.003 & FS 481.221
 3) LICENSE NUMBER REQUIRED ON TITLE
 BLOCK PER FAC 61G1-16.004 & FS 481.2055.
 4) SHT A-1 PLUMBING NOTES: CODE IN
 EFFECT AT THIS TIME IS FBC-2001 NOT THE
 SOUTHERN BUILDING CONGRESS CODE AS IN-
 DICATED. PLEASE CHANGE CODE REFERENCE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-05-12 Cont ID  
Sent By csiegber Date 2004-05-11 Time 08:22 Rev Time 0.00
Received By mmclean Date 2004-05-12 Time 15:08 Sent To I
Notes
***NONE***