Plan Review Details - Permit 04050154
Plan Review Stops For Permit 04050154
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-10-28 Cont ID  
Sent By lsmith Date 2004-10-28 Time 15:21 Rev Time 0.50
Received By lsmith Date 2004-10-28 Time 15:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-08-04 Cont ID  
Sent By btrobaug Date 2004-10-28 Time 14:02 Rev Time 0.50
Received By lsmith Date 2004-08-04 Time 15:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-06-21 Cont ID  
Sent By btrobaug Date 2004-08-02 Time 15:37 Rev Time 0.75
Received By lsmith Date 2004-06-21 Time 10:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-10-28 Cont ID  
Sent By btrobaug Date 2004-10-28 Time 13:59 Rev Time 0.33
Received By btrobaug Date 2004-10-28 Time 13:43 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-08-02 Cont ID  
Sent By btrobaug Date 2004-08-02 Time 15:37 Rev Time 0.33
Received By btrobaug Date 2004-08-02 Time 15:30 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-06-07 Cont ID  
Sent By kstevens Date 2004-08-02 Time 08:38 Rev Time 0.33
Received By btrobaug Date 2004-06-07 Time 07:19 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-10-13 Cont ID  
Sent By csiegber Date 2004-10-13 Time 11:04 Rev Time 0.00
Received By csiegber Date 2004-10-13 Time 11:04 Sent To P
Notes
2004-10-13 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-07-15 Cont ID  
Sent By csiegber Date 2004-07-15 Time 16:48 Rev Time 0.00
Received By csiegber Date 2004-07-15 Time 16:48 Sent To P
Notes
2004-07-15 00:00:00TO KS DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-06-04 Cont ID  
Sent By csiegber Date 2004-06-04 Time 14:08 Rev Time 0.00
Received By csiegber Date 2004-06-04 Time 14:08 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-06-03 Cont ID  
Sent By csiegber Date 2004-06-03 Time 16:48 Rev Time 0.00
Received By csiegber Date 2004-06-03 Time 16:48 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-02 Cont ID  
Sent By mmclean Date 2004-06-03 Time 15:17 Rev Time 0.00
Received By csiegber Date 2004-06-02 Time 14:50 Sent To Z
Notes
2004-06-02 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-05 Cont ID  
Sent By csiegber Date 2004-05-05 Time 15:02 Rev Time 0.00
Received By csiegber Date 2004-05-05 Time 15:02 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-10-28 Cont ID  
Sent By kstevens Date 2004-10-28 Time 13:03 Rev Time 0.50
Received By kstevens Date 2004-10-28 Time 13:03 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-08-02 Cont ID  
Sent By csiegber Date 2004-10-13 Time 11:04 Rev Time 0.50
Received By kstevens Date 2004-08-02 Time 08:37 Sent To E
Notes
2004-08-02 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS.
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)*****SHOWS
 NSPI-4.
 3) FBC-2001 SEC 424.2.6.6 ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. (DETAIL)
 4) FBC-2001424.2.6.6.3 (1,2,3) ENTRAP-
 MENT AVOIDANCE. (DETAIL)**NEW COMMENT*
 5) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 **AN EXTERNAL HARTFORD LOOP WILL BE RE-
 QUIRED AS THERE IS NO INTERNAL MEANS OF
 RETAINING WATER.**
 6) FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.
 7)ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
 8) PLANS ADDED THIS SUBMITTAL ARE SIGNED
 SEALED AND DATED BY ANOTHER ENGINEER AND
 ARE NOT ACCEPTABLE.
 9) SUBMIT A PIPING SCHEMATIC AND POOL
 EQUIPMENT LAYOUT DIAGRAM.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-06-12 Cont ID  
Sent By csiegber Date 2004-07-15 Time 16:48 Rev Time 1.00
Received By kstevens Date 2004-06-12 Time 12:13 Sent To E
Notes
2004-06-12 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS. (ADD TO NOTES)
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 3) FBC-2001 SEC 424.2.6.6 ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. (DETAIL)
 4) FBC-2001424.2.6.6.3 (1,2,3) ENTRAP-
 MENT AVOIDANCE. (DETAIL)
 5) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 6) FBC-2001424.2.7.1 POOL CIRCULATING
 PUMPS SHALL BE EQUIPPED ON THE INLET
 SIDE WITH AN APPROVED TYPE HAIR AND LINT
 STRAINER WHEN USED WITH A PRESSURE FIL-
 TER. (DETAIL OR ADD TO NOTES)
 7) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 8) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 9) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 10) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 11) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 12) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
 13) FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.
 14) SUBMIT 2 SETS OF PLANS FOR REVIEW
 PER SECTION 104.2.1.
 3)ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2004-06-03 Cont ID  
Sent By kstevens Date 2004-10-28 Time 13:03 Rev Time 0.00
Received By mmclean Date 2004-06-03 Time 15:17 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-05-06 Cont ID  
Sent By csiegber Date 2004-06-02 Time 14:50 Rev Time 0.00
Received By mmclean Date 2004-05-06 Time 12:20 Sent To  
Notes
2004-05-06 00:00:00DENIED, MUST BE 2FT ON ZERO SIDE FOR
 DECK & 5FT IN REAR FOR POOL.CALLED
 CONT FOR P/U FILE C MM


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved