Plan Review Details - Permit 04050008
Plan Review Stops For Permit 04050008
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-08-10 Cont ID  
Sent By csiegber Date 2004-08-09 Time 14:58 Rev Time 0.66
Received By alange Date 2004-08-10 Time 08:32 Sent To  
Notes
2004-08-10 00:00:00PARAPET REVISION OK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-09 Cont ID  
Sent By csiegber Date 2004-08-09 Time 14:58 Rev Time 0.00
Received By csiegber Date 2004-08-09 Time 14:58 Sent To B
Notes
2004-08-09 00:00:00TO COMM BD#28

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-08-13 Cont ID  
Sent By pkrauss Date 2004-08-13 Time 07:38 Rev Time 0.45
Received By pkrauss Date 2004-08-13 Time 07:29 Sent To  
Notes
2004-08-13 00:00:00PROVISO:
 PLEASE NOTE IF ROOF ELEVATION IS GREATER
 THAN 16 FT, A PERMENANT MEANS OF ACCESS
 WILL BE REQUIRED PER 2001 FBC(M) 306.5.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-08-17 Cont ID  
Sent By kstevens Date 2004-08-17 Time 14:45 Rev Time 0.33
Received By kstevens Date 2004-08-17 Time 14:44 Sent To  
Notes
2004-08-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SUBMIT CALCULATIONS FOR PRIMARY AND
 SECONDARY ROOF DRAINS PER SECTIONS 1106
 AND 1107 AND ALL SUBSECTIONS. SHOW
 SQUARE FOOTAGE OF ROOF AND 1/2 AREA OF
 ALL VERTICAL WALLS INCLUDING PARAPETS
 ADDED TO SF OF ROOF AREA. INDICATE TOTAL
 AREA BEING DRAINED INTO EACH DRAIN AND
 DOWNSPOUT. SHOW SIZE OF OPENING FOR EACH
 SCUPPER AND DOWNSPOUT. SCUPPER AREA
 SHALL BE SIZED FOR TOTAL AREA DRAINED
 PLUS EMERGENCY OVERFLOW SCUPPER SIZE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]