Plan Review Stops For Permit 04041894 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-06-03 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2004-06-21 |
Time |
16:57 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2004-06-03 |
Time |
12:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-06-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-05-28 |
Time |
14:44 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
2004-06-01 |
Time |
14:54 |
Sent To |
|
|
Notes |
2004-06-01 00:00:00 | SUBMIT CONTRACT TO VERIFY VALUE FOR | | PERMIT VALUATION. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-06-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-14 |
Time |
09:21 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-06-14 |
Time |
09:21 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-05-18 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-11 |
Time |
16:15 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-05-18 |
Time |
17:39 |
Sent To |
P |
|
Notes |
2004-05-18 00:00:00 | ************ UNSAT ************* | | | | 1)NOTE: PLEASE CORRELATE LOAD PLANS/ | | MOTORS AND HEAT PUMP WITH LOAD CALCULAT- | | -IONS. | | PLEASE SEE LOAD SHOWN FOR HEAT PUMP | | DOES NOT CORRELATE WITH HEAT PUMP SPECS. | | PLEASE CIRCLE HEAT PUMP TO BE INSTALLED. | | | | PLEASE SEE PLANS SHOW A 3HP POOL PUMP, | | PLEASE SEE NEC 430 TABLES FOR LOAD OF | | 3HP/230V PUMP. | | | | PLEASE SEE A BLOWER IS INCLUDED ON PLANS | | HOWEVER, THIS IS NOT IN LOAD CALCS? | | | | PLEASE SEE ALL CONTINUOUS LOADS(3 OR | | MORE HRS) IS TO BE FIGURED AT 125%. | | 230.42,215.3,220.19 ETC. | | | | PLEASE RECONFIGURELOAD CALCUALTIONS. | | | | 2)NOTE: PLEASE SEE FBC 104.2.1, ADDITION | | -AL ELECTRICAL LOAD CALCS SHALL CONTAIN | | A PRINTED NAME AND SIGNATURE OF THE | | PERSON RESPONSIBLE FOR PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-06-11 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-11 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-06-11 |
Time |
16:15 |
Sent To |
E |
|
Notes |
2004-06-11 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-05-18 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-18 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-18 |
Time |
16:46 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-05-14 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-05-18 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-14 |
Time |
10:00 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-04-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-27 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-27 |
Time |
16:17 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-06-21 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2004-06-21 |
Time |
16:57 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-05-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-14 |
Time |
09:21 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2004-05-28 |
Time |
14:44 |
Sent To |
B |
|
Notes |
2004-05-28 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | WPB CITY CODE | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | FORMATION REQUIRED FOR PLAN REVIEW | | 1) FBC-2001424.2.6.6.2 SHOW COMPLIANCE | | WITH ANSI/ASME A112.19.8M. PROVIDE MODEL | | NUMBER AND MANUF INFO FOR VAC LOCK. | | (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES) | | 2) FBC-2001424.2.6.6.5 WHERE PROVIDED, | | THE VACUUM OR PRESSURE CLEANER FITTING | | SHALL BE LOCATED AT LEAST 6" AND NOT | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | THE SKIMMER. | | 3) FBC-2001 424.2.9 WATER SUPPLY, LOCAL | | ORD. #2853-95, BACKFLOW REQUIRED ON | | WATER SERVICE. (ADD TO NOTES) | | 4) FBC-2001 424.2.12.1 PRESSURE TESTS. | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | FITTINGS. (ADD TO NOTES) | | 5) FBC-2001 424.2.13.2JOINTS AND CON- | | NECTIONS, FBC PLMG SEC 605.21, PURPLE | | PRIMER REQUIRED ON PVC PIPING. (ADD TO | | NOTES) | | 6) SEE ATTACHED SHEET CONCERNING THE | | WPB CITY ORD. 2853-95 SECTION 31-31 | | BACKFLOW TO BE INSTALLED AND TESTED BY | | THE CITY PRIOR TO POOL PERMIT BEING | | ISSUED. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2004-05-18 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-05-18 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-05-18 |
Time |
09:48 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2004-05-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-14 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-05-03 |
Time |
14:47 |
Sent To |
|
|
Notes |
2004-05-03 00:00:00 | DENIED, NEED TO PROVIDE UTILITY EASEMENT | | APPROVAL.CALLED CONTR FILE H FOR P/U M |
|
|