Plan Review Details - Permit 04041806
Plan Review Stops For Permit 04041806
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-11-12 Cont ID  
Sent By lsmith Date 2004-11-12 Time 13:40 Rev Time 0.25
Received By lsmith Date 2004-11-12 Time 13:40 Sent To  
Notes
2004-11-12 00:00:00ROYALL WALL SYSTEMS ENGINEER LETTER OF
 INSPECTION BY DAVID L. HUSTAD 7/29/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-06-28 Cont ID  
Sent By lsmith Date 2004-06-28 Time 07:43 Rev Time 1.00
Received By lsmith Date 2004-06-28 Time 07:43 Sent To  
Notes
2004-06-28 00:00:00A SEPARATE PERMIT IS REQUIRED FOR THE
 WEATHERGUARD STORM PANELS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-05-21 Cont ID  
Sent By pkrauss Date 2004-06-25 Time 13:46 Rev Time 3.00
Received By lsmith Date 2004-05-21 Time 08:48 Sent To  
Notes
2004-05-21 00:00:00BUILDING PLAN REVIEW; FAILED
  
  
 1. A COPY OF THE RECORDED NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2. THE FLORIDA ENERGY EFFICIENCY CODE
 FORM STATES THE EXTERIOR CONCRETE WALLS
 HAVE AN R-4.2.PLANS STATE R-12.9.
 PLEASECLARIFY.
  
 3.VERIFY THAT ALL USP AND SIMPSON
 CONNECTORS ARE INSTALLED ACCORDING TO
 MANUFACTURERS SPECS. REVISE ON PAGE
 RF-1.
  
 4.ROYAL WALL: SUBMIT A LETTER FROM A
 LICENSED THRESHOLD INSPECTOR STATING
 THAT AN INSPECTION WILL BE MADE AT THE
 MANUFACTURED SITE OF THE JOB SPECIFIC
 COMPONENTS TO VERIFY CONSTRUCTION
 COMPLIANCE OF THE COMPONENTS WITH THE
 ENGINEERED DESIGN.
  
 5. ACCORDING TO SBCCI BUILDING
 VALUATION TABLE THE VALUATION FOR A/C
 SPACE IS @ $76.96. THE UNCONDITIONED
 SPACE REMAINS @ $41.60. THE ADJUSTED
 FEES DUE FOR THIS HOUSE IS $60.75
 BEFOREA PERMIT CAN BE ISSUED.
  
 6. PROVIDE FLORIDA PRODUCT APPROVAL FOR
 THE WEATHERGUARD STORM PANELS.
  
 7. CLARIFY THE MODEL OF THE IMPACT
 WINDOW IN THE DEN.IS IT A MODEL SH701
 IMPACT? IF SO YOU HAVE THE FLORIDA
 PRODUCT APPROVALS SUBMITTED FOR IT.
  
 8ACCORDING TO STATE STATUTE ALL ENGINEER
 AND ARCHITECTS MUST SIGN WITH FULL
 SIGNATURE ALL PLANS & ENGINEERING
 REPORTS.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUIDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-06-23 Cont ID  
Sent By dpalmer Date 2004-06-23 Time 20:15 Rev Time 0.33
Received By dpalmer Date 2004-06-23 Time 20:15 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-05-10 Cont ID  
Sent By csiegber Date 2004-06-23 Time 10:44 Rev Time 0.25
Received By dpalmer Date 2004-05-10 Time 05:12 Sent To M
Notes
2004-05-10 00:00:00******* UNSAT ************
  
 1)NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND. THIS CAN BE A PROVISO BEFORE
 ROUGH, DUE TO THE UNKNOWN # OF FIXTURES
 AT THIS TIME.
  
 2)NOTE: PLEASE HAVE ARCH SIGN WITH
 SIGNATURE. FS 481.221/FAC 61G1-16
  
 3)NOTE: PLEASE SEE SD NEEDS TO BE MOVED
 INTO MASTER BEDRM. SEEMS TO HAVE ANOTHER
 SD MISSING IN OTHER RM? RM DESIGNATION
 NO ON PLANS AT THIS TIME.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-11-12 Cont ID  
Sent By csiegber Date 2004-11-12 Time 11:32 Rev Time 0.00
Received By csiegber Date 2004-11-12 Time 11:32 Sent To B
Notes
2004-11-12 00:00:00TO LS DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-23 Cont ID  
Sent By csiegber Date 2004-06-23 Time 10:44 Rev Time 0.00
Received By csiegber Date 2004-06-23 Time 10:44 Sent To E
Notes
2004-06-23 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-21 Cont ID  
Sent By mmclean Date 2004-04-28 Time 18:10 Rev Time 0.00
Received By lsmith Date 2004-04-27 Time 14:27 Sent To  
Notes
2004-04-29 00:00:00TO SFD RACK/E
2004-04-27 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-06-25 Cont ID  
Sent By pkrauss Date 2004-06-25 Time 13:46 Rev Time 0.35
Received By pkrauss Date 2004-06-25 Time 13:03 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-05-11 Cont ID  
Sent By dpalmer Date 2004-06-23 Time 21:00 Rev Time 0.35
Received By pkrauss Date 2004-05-11 Time 12:44 Sent To P
Notes
2004-05-11 00:00:00DENIED:
 RETURN AIR FROM BEDROOM AREAS ARE NOT
 SIZED PROPERLY.PER THE REVISED 2001
 FBC(M) 601.4 EFFECTIVE JUNE 30, 2003,
 THE RETURN AIR SHALL BE SIZED AS
 FOLLOWS:
  
 BEDROOM SUITE #2 RETURN AIR JUMPER = 12"
 BEDROOM SUITE #3 RETURN AIR JUMPER = 12"
 MASTER SUITE = 14"
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-05-18 Cont ID  
Sent By pkrauss Date 2004-05-11 Time 12:47 Rev Time 0.33
Received By kstevens Date 2004-05-18 Time 17:23 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-04-28 Cont ID  
Sent By mmclean Date 2004-04-28 Time 18:10 Rev Time 0.00
Received By mmclean Date 2004-04-28 Time 18:10 Sent To I
Notes
***NONE***