Plan Review Details - Permit 04041799
Plan Review Stops For Permit 04041799
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-08-11 Cont ID  
Sent By lsmith Date 2004-08-11 Time 15:14 Rev Time 0.50
Received By lsmith Date 2004-08-11 Time 15:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-08-04 Cont ID  
Sent By kstevens Date 2004-08-11 Time 15:03 Rev Time 0.50
Received By lsmith Date 2004-08-04 Time 09:30 Sent To  
Notes
2004-08-04 00:00:00SEE ELEC & PLUMBING NOTES FOR PERMIT LS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-06-29 Cont ID  
Sent By kstevens Date 2004-08-02 Time 17:33 Rev Time 0.50
Received By lsmith Date 2004-06-29 Time 08:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-05-13 Cont ID  
Sent By kstevens Date 2004-06-28 Time 17:57 Rev Time 0.50
Received By lsmith Date 2004-05-13 Time 10:21 Sent To  
Notes
2004-05-13 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. SUBMIT A COPY OF THE CONTRACT TO
 VERIFY THE VALUE OF THE WORK INCLUDED
 ON THIS PERMIT. ACCORDING TO FBC104.6.5
 PERMIT FEES ARE BASED ON TOTAL VALUE
 OF THE CONTRACT.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-08-06 Cont ID  
Sent By btrobaug Date 2004-08-11 Time 14:36 Rev Time 1.00
Received By btrobaug Date 2004-08-06 Time 09:21 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-07-23 Cont ID  
Sent By dpalmer Date 2004-07-23 Time 14:53 Rev Time 0.33
Received By dpalmer Date 2004-07-23 Time 14:53 Sent To P
Notes
2004-07-23 00:00:00********** UNSAT ***************
  
 1)NOTE: PLEASE SEE OLD SHEETS WHICH
 CONTAIN COPIES OF SIGNED AND SEAL PLANS
 AND PLANS WHICH ARE NOT SIGNED AND SEAL-
 -ED AND OR DO NO NEED TO BE IN PLAN SETS
  
 2)NOTE: PLEASE SEE NEW SHEET 8 1/2 X 11
 ADDED FOR FEED TO POOL EQUIPMENT IS NOW
 MISSING CA # PER FS 471.023,FAC 61G15-
 23.002
  
 3)NOTE: PLEASE SEE PLANS FROM BEA,
 PLANS STILL SHOW A 125 A PANEL. IS THIS
 THE VAK PANEL? IS THIS THE PANEL FED
 FROM CHOUSE? IF SO, NO INDICATION OF
 OCP TO WHAT IS SHOWN AS 30A DISC/MAIN
 POOL SWITCH?
 PLEASE SEE FEEDERS TO 30A SWITCH ARE
 SHOWN AS #1'S??
 RISER AS SHOWN ON BEA PLANS NEED
 CLARIFICATION.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-06-16 Cont ID  
Sent By csiegber Date 2004-07-21 Time 09:27 Rev Time 0.33
Received By dpalmer Date 2004-06-16 Time 13:40 Sent To P
Notes
2004-06-16 00:00:00************** UNSAT ***************
  
 1)NOTE: PLEASE CORRELATE PLANS SUBMITTED
 FOR POOL/EQUIPMENT VAK PAK / FEEDS ETC
 WITH CLUBHOUSE PLANS SUBMITTED FOR REF.
 CH PLANS SHOW 100A FEED W/ #3'S ETC.
 PLEASE SEE PLANS PER BEA INDICATE #10'S
 30A?
 PLEASE CLARIFY WHERE THIS CHANGES OVER
 OR IS THIS AN ERROR.
  
 PLEASE CORRELATE AND SUBMIT.
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 SUBMIT REVISED SHEETS INTO TWO COMPLETE
 SETS FOR REVIEW AND STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-05-08 Cont ID  
Sent By csiegber Date 2004-06-11 Time 12:50 Rev Time 0.25
Received By dpalmer Date 2004-05-08 Time 08:23 Sent To P
Notes
2004-05-08 00:00:00*************** UNSAT **************
  
 1)NOTE: PLEASE HAVE ENGINEER SIGN W/
 FULL FIRST NAME. INITIALS ARE NOT
 PERMITTED FS 471.025,FBPE'S.
  
 2)NOTE: PLEASE SEE COPIES OF PLANS
 SUBMITTED WHICH ARE COPIES??
  
 3)NOTE: IS PANEL SCHEDULE SHOWN ON 2OF6
 PANEL TO FEED NEW VAK PACK OR IS THIS
 THE VAK PAK PANEL?
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-08-04 Cont ID  
Sent By csiegber Date 2004-08-04 Time 12:48 Rev Time 0.00
Received By csiegber Date 2004-08-04 Time 12:48 Sent To  
Notes
2004-08-04 00:00:00TO COMM BD#42

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-07-21 Cont ID  
Sent By csiegber Date 2004-07-21 Time 09:27 Rev Time 0.00
Received By csiegber Date 2004-07-21 Time 09:27 Sent To E
Notes
2004-07-21 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-06-11 Cont ID  
Sent By csiegber Date 2004-06-11 Time 12:50 Rev Time 0.00
Received By csiegber Date 2004-06-11 Time 12:50 Sent To E
Notes
2004-06-11 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-05-06 Cont ID  
Sent By csiegber Date 2004-05-06 Time 08:23 Rev Time 0.00
Received By csiegber Date 2004-05-06 Time 08:23 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-27 Cont ID  
Sent By mmclean Date 2004-05-05 Time 15:15 Rev Time 0.00
Received By csiegber Date 2004-04-27 Time 16:50 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2004-08-11 Cont ID  
Sent By kstevens Date 2004-08-11 Time 15:03 Rev Time 0.50
Received By kstevens Date 2004-08-11 Time 15:03 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-08-02 Cont ID  
Sent By btrobaug Date 2004-08-11 Time 14:36 Rev Time 0.33
Received By kstevens Date 2004-08-02 Time 17:33 Sent To B
Notes
2004-08-02 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1) PER DUTCH HOLLAND, HEALTH DEPT. PLAN
 REVIEW, PLANS SHALL BE RESUBMITTED TO
 HEALTH DEPT FOR REVIEW OF NEW SHEETS
 SUBMITTED BECAUSE OF NEW ENGINEER.
 RESUBMIT FOR REVIEW AFTER HEALTH DEPT.
 STAMPS NEW SHEETS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-06-28 Cont ID  
Sent By dpalmer Date 2004-07-23 Time 14:54 Rev Time 1.00
Received By kstevens Date 2004-06-28 Time 17:52 Sent To B
Notes
2004-06-28 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1) SUBMIT TWO SETS OF PLANS FOR REVIEW.
 REMOVE OLD SHEETS, EXCEPT SHEET 1 WITH
 THE HEALTH DEPT PLAN REVIEW STAMP, AND
 SUBMIT ONE COPY OF ALL OLD SHEETS FOR
 COMPAIRSON. SECTION 104.2.1.
 2) SEE NEW CALCULATED VALUATION PER
 MARSHALL & SWIFT REQUIRED BY SECTION
 104.6.5. FEES DUE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-06-09 Cont ID  
Sent By dpalmer Date 2004-06-16 Time 13:40 Rev Time 1.50
Received By spalmer Date   Time   Sent To B
Notes
2004-05-12 00:00:00PLU,BING PLAN REVIEW,DENIED FBC 2001
 1) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 2 ) 61G1-16.004FL. ADMIN. CODE.PLANS
 PREPARED BY A REGISTERED ARCHITECT SHALL
 INCLUDE A TITLE BLOCK WHICH MUST:
 - STATE THE FIRM NAME, ADDRESS AND
 TELEPHONE NUMBER
 - STATE THE FIRM LICENSE NUMBER
 - STATE PROJECT NAME OR IDENTIFICATION
 - STATE DATE PREPARED
 - INCLUDE AN ORIGINAL SIGNATURE AND
 DATED SEAL
 - INCLUDE THE PRINTED NAME OF THE
 ARCHITECT SEALING THE PLANS
 (3) SEC 424.2.12.1 PRESSURE TEST.
 NO AIR TEST WILL BE APPROVED FOR PVC
 PIPE.
 (4) SEC 424.2.13.2 JOINTS, CONNECTIONS.
 PURPLE PRIMER, REQUIRED ON PVC PIPING.
 (5) SEC 104.6.5 BUILDING PERMIT VALUE.
 VALUATION BASED ON TOTAL REPLACEMENT
 VALUE.TO INCLUDE STRUCTAL, ELECTRICAL
 PLUMBING, MECHANICAL,INTERIOR FINISH,
 NORMAL SITE WORK,ARCHITECTURAL & DESIGN
 FEES, EXCLUDING ONLY LAND VALUE.
 (6) FPC 2001 SEC 310.3 CONNECTION TO
 THE DRAINAGE SYSTEM.SHT 1 VAC PCAK
 WASTE TO SANITARY SEWER.
 END OF COMMENTS QUESTIONS 561-805-6692

Review Stop Z ZONING
Rev No 1 Status P Date 2004-05-05 Cont ID  
Sent By csiegber Date 2004-04-27 Time 16:50 Rev Time 0.00
Received By mmclean Date 2004-05-05 Time 15:15 Sent To I
Notes
2004-05-05 00:00:00OK BY GRACE JOYCE, PLANNER 659-8031


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved