Plan Review Stops For Permit 04041684 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-10-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-10-12 |
Time |
17:50 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2004-10-12 |
Time |
17:50 |
Sent To |
PC |
|
Notes |
2004-10-12 00:00:00 | GARAGE DOOR PRODUCT APPROVAL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-07-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-30 |
Time |
10:05 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2004-07-16 |
Time |
16:04 |
Sent To |
PC |
|
Notes |
2004-07-16 00:00:00 | 1-PROVIDE COPIES OF GARAGE DOOR DRAWINGS | | SUBMITTED TO SBCCI FOR APPROVAL. NEED | | DRAWINGS SIGNED AND SEALED ON DATE | | NOTED ON SBCCI EVALUATION REPORT. | | | | 2-FLOOD ZONE REVISION IS OK. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT 805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-05-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-22 |
Time |
14:34 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2004-05-19 |
Time |
09:25 |
Sent To |
PC |
|
Notes |
2004-05-19 00:00:00 | BUILDING REVIEW PROVISO: | | 1-SUBMIT COPY OF THE DRAWINGS THAT WERE | | SUBMITTED TO SBCCI FOR APPROVAL. | | DRAWINGS SUBMITTED DON'T HAVE THE SAME | | DATE THAT ENGINEER SIGNED AND SEALED | | PLANS AS SPECIFIED ON SBCCI REPORT. | | 2-FLOOD ZONE AO: NEED TO PROVIDE THE | | ELEVATION CERTIFICATE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-05-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-06 |
Time |
06:00 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-05-06 |
Time |
06:00 |
Sent To |
M |
|
Notes |
2004-05-06 00:00:00 | ****** REDLINED / PROVISO ********* | | | | REVISE PLANS BEFORE ROUGH. | | | | 1)NOTE: PLEASE SEE MAX LOAD FOR 1P20A | | CIRCUIT IS 1.9 KW. IRRG PUMP, WASHER | | ARE BOTH SHOWN AT 2KW. | | | | 2)NOTE: PLEASE SEE MIN LOAD FOR RANGE | | IS 8KW, 220.19 | | | | SD'S TO BE INSTALLED PER NFPA-72 8-1.4.2 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-08-30 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-30 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-30 |
Time |
10:05 |
Sent To |
B |
|
Notes |
2004-08-30 00:00:00 | TO JG DESK/SUBMITTALS/NEW PA'S |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-06-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-22 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-06-22 |
Time |
14:34 |
Sent To |
B |
|
Notes |
2004-06-22 00:00:00 | TO JG DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-05-19 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-04-28 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2004-04-26 |
Time |
13:32 |
Sent To |
PC |
|
Notes |
2004-04-29 00:00:00 | TO SFD RACK/E | 2004-04-26 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2004-05-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-06 |
Time |
06:00 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2004-05-10 |
Time |
16:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-05-18 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-05-18 |
Time |
18:31 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-05-18 |
Time |
18:31 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-04-28 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-04-28 |
Time |
12:38 |
Sent To |
I |
|
Notes |
|
|