Plan Review Stops For Permit 04041658 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-10-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-10-13 |
Time |
16:17 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2004-10-13 |
Time |
16:17 |
Sent To |
PC |
|
Notes |
2004-10-13 00:00:00 | GARAGE DOOR PRODUCT APPROVAL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-07-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-30 |
Time |
09:34 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2004-07-19 |
Time |
15:52 |
Sent To |
PC |
|
Notes |
2004-07-19 00:00:00 | 1-PROVIDE COPIES OF GARAGE DOOR DRAWINGS | | SUBMITTED TO SBCCI FOR APPROVAL. NEED | | DRAWINGS SIGNED AND SEALED ON DATE | | NOTED ON SBCCI EVALUATION REPORT. | | 2-DETAIL E/4 AND RESIDENTIAL NOTES ON | | DWG #2 DON'T MATCH. CLARIFY FASTENER | | SPACING. SECTION 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. | | 3-SECTION A4: SPECIFY WHERE ARE TABLES | | 6 AND 8 TAKEN FROM. SECTION 104.2.1.2 | | CITY AMENDMENTS TO FBC 2001. | | 4-FLOOD ZONE REVISION IS OK. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT 805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-05-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-22 |
Time |
14:39 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2004-05-20 |
Time |
11:52 |
Sent To |
PC |
|
Notes |
2004-05-20 00:00:00 | BUILDING REVIEW PROVISO: | | 1-PROVIDE COPIES OF GARAGE DOORS DWGS | | THAT WERE PRESENTED TO SBCCI FOR | | APPROVAL. NEED DWGS WITH THE SAME DATE | | THEY WERE SIGNED AND SEALED AS NOTED | | ON SBCCI EVALUATION REPORT. | | 2-DETAIL E/4 AND RESIDENTIAL NOTES ON | | SHEET #2 DON'T MATCH. CLARIFY FASTENER | | SPACING. SEC. 104.2.1.2 OF CITY | | AMENDMENTS TO FBC 2001. | | 3-SECTION A/4: SPECIFY WHERE ARE TABLES | | 6 AND 8 FOR ROOF TILE FASTENER TAKEN | | FROM. SEC. 104.2.1.1 CITY AMENDMENTS | | TO FBC 2001. | | 4-FLOOD ZONE AO: NEED TO PROVIDE THE | | ELEVATION CERTIFICATE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-05-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-06 |
Time |
06:09 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-05-06 |
Time |
06:09 |
Sent To |
M |
|
Notes |
2004-05-06 00:00:00 | NOTED SD'S INSTALLED PER NFPA-72 8-1.4.2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-08-30 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-30 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-30 |
Time |
09:34 |
Sent To |
B |
|
Notes |
2004-08-30 00:00:00 | TO JG DESK/SUBMITTAL/NEW PA'S |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-06-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-22 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-06-22 |
Time |
14:38 |
Sent To |
B |
|
Notes |
2004-06-22 00:00:00 | TO JG DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-05-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-29 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2004-04-26 |
Time |
13:29 |
Sent To |
PC |
|
Notes |
2004-04-29 00:00:00 | TO SFD RACK/E | 2004-04-26 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2004-05-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-06 |
Time |
06:09 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2004-05-10 |
Time |
16:45 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-05-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-05-10 |
Time |
16:45 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-05-19 |
Time |
09:40 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-29 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-28 |
Time |
16:48 |
Sent To |
I |
|
Notes |
2004-04-29 00:00:00 | PASSED PER MM DEE |
|
|