Plan Review Stops For Permit 04041648 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-10-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-10-14 |
Time |
07:54 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2004-10-14 |
Time |
07:54 |
Sent To |
PC |
|
Notes |
2004-10-14 00:00:00 | GARAGE DOOR PRODUCT APPROVAL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-07-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-30 |
Time |
10:02 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2004-07-20 |
Time |
09:46 |
Sent To |
PC |
|
Notes |
2004-07-20 00:00:00 | 1-PROVIDE COPIES OF GARAGE DOOR DRAWINGS | | SUBMITTED TO SBCCI FOR APPROVAL. NEED | | DRAWINGS SIGNED AND SEALED ON DATE | | NOTED ON SBCCI EVALAUTION REPORT. | | 2-FLOOD ZONE REVISION IS OK. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT 805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-05-13 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-22 |
Time |
14:38 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2004-05-13 |
Time |
17:09 |
Sent To |
PC |
|
Notes |
2004-05-13 00:00:00 | BUILDING REVIEW PROVISO: | | 1-GARAGE DOORS: DWGS SUBMITTED DON'T | | MATCH DWGS SUBMITTED TO SBCCI FOR | | EVALUATION APPROVAL. RESUBMIT MATCHING | | DWGS. SEE DATE DRAWINGS WERE SIGNED & | | SEALED BY ENGINEER OF RECORD. | | 2-FLOOD ZONE AO: NEED TO PROVIDE THE | | ELEVATION CERTIFICATE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-05-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-03 |
Time |
07:28 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-05-03 |
Time |
07:28 |
Sent To |
M |
|
Notes |
2004-05-03 00:00:00 | ******** REDLINED/ PROVISO******* | | | | REVISE PLANS BEFORE ROUGH. | | | | 1)NOTE: PLEASE SEE MIN LOAD FIGURED FOR | | RANGE TO BE 8KW PER 220.19. SHOWN AS | | 7.5KW | | | | 2)NOTE: MAX LOAD FOR 1-P 20A CIRCUITS | | 1.9KW,80% IRRG PUMP,WASHER ARE SHOWN AS | | 2KW | | | | SD'S PER NFPA-72 8-1.4.2 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-08-30 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-30 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-30 |
Time |
10:02 |
Sent To |
B |
|
Notes |
2004-08-30 00:00:00 | TO JG DESK/SUBMITTALS/NEW PA'S |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-06-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-22 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-06-22 |
Time |
14:37 |
Sent To |
B |
|
Notes |
2004-06-22 00:00:00 | TO JG DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-05-13 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-04-28 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2004-04-23 |
Time |
11:09 |
Sent To |
PC |
|
Notes |
2004-04-29 00:00:00 | 4/29/04 TO SFD RACK/E | 2004-04-26 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2004-05-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-03 |
Time |
07:28 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2004-05-07 |
Time |
08:47 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-05-08 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-05-07 |
Time |
08:47 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2004-05-08 |
Time |
07:41 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-04-28 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-04-28 |
Time |
13:57 |
Sent To |
I |
|
Notes |
|
|