Plan Review Details - Permit 04041517
Plan Review Stops For Permit 04041517
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-11-15 Cont ID  
Sent By jgomez Date 2004-11-15 Time 10:56 Rev Time 0.00
Received By jgomez Date 2004-11-15 Time 10:52 Sent To PC
Notes
2004-11-15 00:00:00SURVEY REVISED SHOWING CORRECT NORTH
 ARROW ORIENTATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-10-07 Cont ID  
Sent By jgomez Date 2004-10-07 Time 12:14 Rev Time 0.33
Received By jgomez Date 2004-10-07 Time 12:14 Sent To PC
Notes
2004-10-07 00:00:00CHECKLIST:
 1-REVISE SURVEY. NORTH ARROW ORIENTATION
 SHOWN ON ENLARGED PLAN IS INCORRECT.
  
 **GARAGE DOOR PRODUCT APPROVAL OK.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-07-20 Cont ID  
Sent By csiegber Date 2004-08-30 Time 10:09 Rev Time 0.33
Received By jgomez Date 2004-07-20 Time 15:26 Sent To PC
Notes
2004-07-20 00:00:00REVISION CHECKLIST:
 1-NORTH ARROW ORIENTATION SHOWN ON
 SURVEY IS INCORRECT. SEE LOCATION
 MAP FOR RIGHT ORIENTATION.
 2-PROVIDE COPIES OF GARAGE DOOR DRAWINGS
 SUBMITTED TO SBCCI FOR APPROVAL. NEED
 DRAWINGS SIGNED AND SEALED ON DATE
 NOTED ON SBCCI EVALUATION REPORT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-05-18 Cont ID  
Sent By csiegber Date 2004-06-22 Time 14:39 Rev Time 1.00
Received By jgomez Date 2004-05-17 Time 16:57 Sent To PC
Notes
2004-05-17 00:00:00BUILDING REVIEW PROVISO:
 1-PROVIDE GARAGE DOORS DWGS THAT MATCH
 SBCCI REPORT. NEED DWGS THAT ENGINEER
 SIGNED AND SEALED WITH SAME DATE AS
 SUBMITTED TO SBCCI.
 2-NORTH ARROW ORIENTATION SHOWN ON
 SURVEY IS INCORRECT. REVISE AS REQ'D.
 3-FLOOD ZONE AO: NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-05-03 Cont ID  
Sent By dpalmer Date 2004-05-03 Time 05:26 Rev Time 0.25
Received By dpalmer Date 2004-05-03 Time 05:26 Sent To M
Notes
2004-05-03 00:00:00**** REDLINED **********
  
 SD'D PER NFPA-72 8-1.4.2
 RANGE SHOULD BE A MIN OF 8KW, SHOWN AT
 7.5
 WASHER SHOWN AT 2KW, OVERLOADS 20A CIR.
  
 REVISE PLANS.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-11-04 Cont ID  
Sent By csiegber Date 2004-11-04 Time 15:07 Rev Time 0.00
Received By csiegber Date 2004-11-04 Time 15:07 Sent To B
Notes
2004-11-04 00:00:00TO JG DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-08-30 Cont ID  
Sent By csiegber Date 2004-08-30 Time 10:09 Rev Time 0.00
Received By csiegber Date 2004-08-30 Time 10:09 Sent To B
Notes
2004-08-30 00:00:00TO JG DESK/SUBMITTALS/NEW PA'S

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-22 Cont ID  
Sent By csiegber Date 2004-06-22 Time 14:39 Rev Time 0.00
Received By csiegber Date 2004-06-22 Time 14:39 Sent To B
Notes
2004-06-22 00:00:00TO JG DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-18 Cont ID  
Sent By jgomez Date 2004-05-18 Time 08:40 Rev Time 0.00
Received By jgomez Date 2004-04-22 Time 10:18 Sent To PC
Notes
2004-04-29 00:00:004/22/04 TO Z
 4/29/04 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-05-05 Cont ID  
Sent By dpalmer Date 2004-05-03 Time 05:32 Rev Time 0.25
Received By pkrauss Date 2004-05-05 Time 11:39 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-05-08 Cont ID  
Sent By pkrauss Date 2004-05-05 Time 12:04 Rev Time 0.25
Received By jleech Date 2004-05-08 Time 06:40 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-04-28 Cont ID  
Sent By mmclean Date 2004-04-28 Time 15:45 Rev Time 0.00
Received By mmclean Date 2004-04-28 Time 15:45 Sent To I
Notes
***NONE***