Plan Review Stops For Permit 04041411 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-05-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-05-24 |
Time |
13:13 |
Rev Time |
2.25 |
Received By |
alange |
Date |
2004-05-07 |
Time |
13:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-02-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-02-08 |
Time |
17:43 |
Rev Time |
0.20 |
Received By |
dpalmer |
Date |
2005-02-08 |
Time |
17:43 |
Sent To |
|
|
Notes |
2005-02-08 00:00:00 | REDLINED POOL PANEL INTO PANEL SCHEDULE | | ALONG W/ AWG. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-05-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-12 |
Time |
16:50 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-05-12 |
Time |
16:50 |
Sent To |
M |
|
Notes |
2004-05-12 00:00:00 | *** PROVISO ** | | | | ALL REVISIONS TO BE SUBMITTED FOR | | REVIEW | | BEFORE ROUGH. | | | | 1 )NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY | | NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | DUE TO THE ACTUAL UNKNOWN FIXTURES | | BEING | | INSTALLED AT THIS TIME. PLEASE SUBMIT | | REVISED BEFORE ROUGH.. | | | | 2)NOTE: PLEASE SEE 210.52 | | | | IF THERE ARE ANY QUESTIONS, PLEASE | | CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-04-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-11 |
Time |
15:36 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-04-26 |
Time |
06:29 |
Sent To |
P |
|
Notes |
2004-04-26 00:00:00 | *************** UNSAT *************** | | | | 1)NOTE: PLEASE SEE FBC 104.2.1 | | PLANS MUST HAVE TH PRINTED NAME AND | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | DESIGN/PLANS. | | | | 2)NOTE: PLEASE SEE 210.52C1 FOR SPACING | | OF RECEPTS ALONG KITCHEN COUNTERSPACE. | | PLEASE SEE TWO COUNTER AREAS APPEAR TO | | BE OVER 4' AND ONLY ONE RECEPT SHOWN. | | | | 3)NOTE: PLEASE SEE 210.52 FOR RECEPT | | SPACING. 2', 6' RULE. | | PLEASE SEE BR#3, AND GRT RM. | | | | 4)NOTE: PLEASE SEE NEC ART 384 REFERENC- | | -ED ON PANEL SCHEDULE. 384 IS OUT OF THE | | 1999 NEC. AS OF 7/1/2003, THE STATE HAS | | ADOPTED THE 2002 NEC. THE ART # HAS | | CHANGED. | | | | PLEASE SEE ONE SET OF PLANS AHVE BEEN | | MNARKED UP FOR THE ABOVE AREAS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-02-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-02-08 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-02-08 |
Time |
08:51 |
Sent To |
E |
|
Notes |
2005-02-08 00:00:00 | TO DP. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-01-28 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-28 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-28 |
Time |
10:29 |
Sent To |
E |
|
Notes |
2005-01-28 00:00:00 | TO "DP" DESK/REV. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-05-11 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-11 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-11 |
Time |
15:36 |
Sent To |
E |
|
Notes |
2004-05-11 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-04-22 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-04-22 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2004-04-22 |
Time |
13:58 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-05-07 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-04-21 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2004-04-20 |
Time |
16:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-05-24 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-05-24 |
Time |
13:05 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2004-05-24 |
Time |
13:01 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-04-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-12 |
Time |
16:50 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2004-04-28 |
Time |
09:30 |
Sent To |
P |
|
Notes |
2004-04-28 00:00:00 | DENIED: | | PLEASE REVISE THE FOLLOWING: | | | | RETURN AIR TO THE MASTER BEDROOM IS NOT | | SIZED PROPERLY.A DUCTED RETURN SHALL | | BE EQUAL TO THE SUPPLY AIR INTO THAT | | SPACE.ALL AIR INTO THE MASTER SUITE | | IS TO BE INCLUDED.2001 FBC(M) 601.4 & | | EXCEPTION #3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2004-05-03 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-04-28 |
Time |
09:31 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2004-05-03 |
Time |
19:35 |
Sent To |
B |
|
Notes |
2004-05-03 00:00:00 | NOT ENOUGH INFORMATION TO DO A PLUMBING | | PLAN REVIEW. NO SANITARY RISER DIAGRAM. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-04-21 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-04-21 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-04-21 |
Time |
10:52 |
Sent To |
I |
|
Notes |
|
|