Plan Review Stops For Permit 04041341 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2005-05-17 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-05-17 |
Time |
11:18 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2005-05-17 |
Time |
11:16 |
Sent To |
|
|
Notes |
2005-05-17 00:00:00 | STAMPED AND ISSUED |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2005-04-25 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-04-25 |
Time |
10:16 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2005-04-25 |
Time |
10:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2005-02-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-02-18 |
Time |
15:24 |
Rev Time |
1.00 |
Received By |
alange |
Date |
2005-02-18 |
Time |
15:24 |
Sent To |
|
|
Notes |
2005-02-18 00:00:00 | DENIED | | | | ITEMS FROM LAST REVIEW: | | | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY | | COURTHOUSEAND A COPY SUBMITTED TO THIS | | OFFICE | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | 5.WINDOW AND DOOR BUCKS SHALL COMPLY | | WITH FBC 1707.4.4.2BUCKS SHALL EXTEND | | BEYOND THE INTERIOR FACE OF THE WINDOW | | AND DOOR FRAME SUCH THAT FULL SUPPORT | | OF THE FRAME IS PROVIDED.SHOW DETAIL. | | | | 6.SUBMIT COPY OF THE COVENANTS THAT | | HAVE BEEN AMENDED AND RECORDED WITH | | PALM BEACH COUNTY TO CREATE AN | | EMERGENCY EGRESS THROUGH THE ADJOINING | | LOT ON THE ZERO LOT LINE SIDE OF THE | | STRUCTURE. | | 1001.1.3/ 1005.4 ZERO LOT LINE | | EGRESS:WHEN ACCESS TO OR FROM A RE- | | QUIRED EMERGENCY ESCAPE AND RESCUE OPEN- | | ING OF A STRUCTURE TO THE PUBLIC WAY, | | REQUIRES TRANSVERSING A PROPERTY | | (ADJOINING LOT) THAT IS NOT PART OF THE | | ONE WHICH THE STRUCTURE IS LOCATED, AN | | EGRESS EASEMENT THROUGH THE ADJOINING | | PROPERTY IS REQUIRED AND SHALL BE RECORD | | ED IN THE COUNTY RECORDS. THIS EASEMENT | | SHALL BE A MINIMUM OF 3' WIDE AND NOTH- | | ING SHALL BE PLACED WITHIN THE EASEMENT | | AREA WHICH WOULD BLOCK ACCESS TO THE | | EASEMENT AND OR IMPEDE EMERGENCY EGRESS | | FROM THE RESCUE OPENING TO THE PUBLIC | | WAY. NO LANDSCAPING, FENCES OR OTHER | | IMPEDIMENTS SHALL BE INSTALLED IN THIS | | EASEMENT. | | | | NEW COMMENT:GARDEN COURT TABLE 6OO | | CALCULATIONS ARE INCORRECT. | | TOTAL AREA 9' X 12' = 108SQ. FT. | | OPENINGS 3 X 7 = 21 | | 9 X .75 = 6.75 TOTAL 27.75SQ FT. | | PERCENTAGE OF OPENINGS IS TOO HIGH. | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | ON THE APPLICATION, PLANS, OR ATTACHED | | SEPARATELY. WHEN RESUBMITTING PLANS | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | ART LANGE | | BUILDING PLAN REVIEW | | TEL: (561)805-6672 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-09-14 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-09-14 |
Time |
09:03 |
Rev Time |
1.50 |
Received By |
alange |
Date |
2004-09-14 |
Time |
09:03 |
Sent To |
|
|
Notes |
2004-09-14 00:00:00 | DENIED | | | | ITEMS FROM LAST REVIEW: | | | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY | | COURTHOUSEAND A COPY SUBMITTED TO THIS | | OFFICE | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 3.SUBMIT 2 SIGNED COPIES OF ENERGY | | CALCS. | | | | 5.WINDOW AND DOOR BUCKS SHALL COMPLY | | WITH FBC 1707.4.4.2BUCKS SHALL EXTEND | | BEYOND THE INTERIOR FACE OF THE WINDOW | | AND DOOR FRAME SUCH THAT FULL SUPPORT | | OF THE FRAME IS PROVIDED.SHOW DETAIL. | | | | 6.SUBMIT COPY OF THE COVENANTS THAT | | HAVE BEEN AMENDED AND RECORDED WITH | | PALM BEACH COUNTY TO CREATE AN | | EMERGENCY EGRESS THROUGH THE ADJOINING | | LOT ON THE ZERO LOT LINE SIDE OF THE | | STRUCTURE. | | 1001.1.3/ 1005.4 ZERO LOT LINE | | EGRESS:WHEN ACCESS TO OR FROM A RE- | | QUIRED EMERGENCY ESCAPE AND RESCUE OPEN- | | ING OF A STRUCTURE TO THE PUBLIC WAY, | | REQUIRES TRANSVERSING A PROPERTY | | (ADJOINING LOT) THAT IS NOT PART OF THE | | ONE WHICH THE STRUCTURE IS LOCATED, AN | | EGRESS EASEMENT THROUGH THE ADJOINING | | PROPERTY IS REQUIRED AND SHALL BE RECORD | | ED IN THE COUNTY RECORDS. THIS EASEMENT | | SHALL BE A MINIMUM OF 3' WIDE AND NOTH- | | ING SHALL BE PLACED WITHIN THE EASEMENT | | AREA WHICH WOULD BLOCK ACCESS TO THE | | EASEMENT AND OR IMPEDE EMERGENCY EGRESS | | FROM THE RESCUE OPENING TO THE PUBLIC | | WAY. NO LANDSCAPING, FENCES OR OTHER | | IMPEDIMENTS SHALL BE INSTALLED IN THIS | | EASEMENT. | | | | 7.BUILDING VALUE TO LOW.ADDITIONAL | | PERMIT FEES OF $693.74 ARE DUE. | | | | NEW: | | A.SOIL REPORT SUBMITTED ARE NOT SIGNED | | AND SEALED. | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | ON THE APPLICATION, PLANS, OR ATTACHED | | SEPARATELY. WHEN RESUBMITTING PLANS | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | ART LANGE | | BUILDING PLAN REVIEW | | TEL: (561)805-6672 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-05-05 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-08-27 |
Time |
16:39 |
Rev Time |
2.50 |
Received By |
alange |
Date |
2004-05-05 |
Time |
15:22 |
Sent To |
|
|
Notes |
2004-05-05 00:00:00 | DENIED | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY | | COURTHOUSEAND A COPY SUBMITTED TO THIS | | OFFICE | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 3.SUBMIT 2 COPIES OF ENERGY CALCS. | | | | 4.PRODUCT APPROVALS SUBMITTED ARE NOT | | COMPLETE, SUBMIT 2 COPIES FOR ONLY | | PRODUCTS USED ON THIS PROJECT. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, | | 2003ARE REQUIRED TO COMPLY WITH THE | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | ATTACH APPROVALS TO YOUR NOA'S | | | | 5.WINDOW AND DOOR BUCKS SHALL COMPLY | | WITH FBC 1707.4.4.2BUCKS SHALL EXTEND | | BEYOND THE INTERIOR FACE OF THE WINDOW | | OR DOOR FRAME SUCH THAT FULL SUPPORT OF | | THE FRAME IS PROVIDED.SHOW DETAIL. | | | | 6. SUBMIT A COPY OF THE COVENANTS THAT | | HAS BEEN AMENDED AND RECORDED WITH PALM | | BEACH COUNTY TO CREATE AN EMERGENCY | | EGRESS THROUGH THE ADJOINING LOT ON THE | | ZERO LOT LINE SIDE OF THE STRUCTURE. | | 1001.1.3/ 1005.4 ZERO LOT LINE | | EGRESS:WHEN ACCESS TO OR FROM A RE- | | QUIRED EMERGENCY ESCAPE AND RESCUE | | OPEN-ING OF A STRUCTURE TO THE PUBLIC | | WAY, | | REQUIRES TRANSVERSING A PROPERTY | | (ADJOINING LOT) THAT IS NOT PART OF THE | | ONE WHICH THE STRUCTURE IS LOCATED, AN | | EGRESS EASEMENT THROUGH THE ADJOINING | | PROPERTY IS REQUIRED AND SHALL BE | | RECORDED IN THE COUNTY RECORDS. THIS | | EASEMENT SHALL BE A MINIMUM OF 3' WIDE | | AND NOTH- ING SHALL BE PLACED WITHIN | | THE EASEMENT AREA WHICH WOULD BLOCK | | ACCESS TO THE | | EASEMENT AND OR IMPEDE EMERGENCY EGRESS | | FROM THE RESCUE OPENING TO THE PUBLIC | | WAY. NO LANDSCAPING, FENCES OR OTHER | | IMPEDIMENTS SHALL BE INSTALLED IN THIS | | EASEMENT. | | | | 7.BUIDING VALUE OF $220,000 IS TO LOW | | BASED UPON SBCCI BUILDING VALUATION | | DATATHE VALUATION HAS BEEN REVISED TO | | $288,687.ADDITIONAL PERMIT FEES | | ARE DUE. | | | | 8.SQUARE FOOTAGE ON APPLICATION WAS | | NOT ACCURATE AND HAS BEEN REVISED. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
11 |
Status |
P |
Date |
2006-07-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-06 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-06 |
Time |
16:49 |
Sent To |
PC |
|
Notes |
2006-07-06 00:00:00 | REDLINED POOL PANEL LOCATION. | | | | MANY CIRCUITS SHOWING CONDUCTOR SIZES | | LARGER THAN NEEDED, HOWEVER THIS IS OK. | | IF SHOWN ON PLANS THIS WAY, THIS IS WHAT | | SHOULD BE INSTALLED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
10 |
Status |
F |
Date |
2006-07-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-03 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-03 |
Time |
07:40 |
Sent To |
PC |
|
Notes |
2006-07-03 00:00:00 | ******** UNSAT *********** | | | | 1) NOTE: PLEASE SEE NUMEROUS ITEMS ON | | PANEL SCHEDULE AND LOCD CALCULATIONS | | WHICH STILL DO NOT CORRELATE. | | PLEASE SEE AHU'S, SPA, POOL, DISHWASHER | | (S), LAUNDRY/WASHER, ETC ETC. | | PLEASE SEE PANELS STILL DO NOT | | CORRELATE. | | 215.5,240.4,310.16, ( 2002 NEC) | | | | 2) NOTE: PLEASE SHOW EACH PANEL WITH | | CORRECT LOADS AND LOAD CALCULATIONS PER | | NEC 220. | | PLEASE SEE THE LOADS FOR "B". | | | | 3) NOTE: PLEASE SEE MIN LT FIX REQUIRED | | FOR EGRESS. LS 101 7.8, 210.70 | | | | 4) NOTE: PLEASE SEE THAT THE RISER AND | | PANELS STILL DO NOT CORRELATE. | | LOADS DO NOT CORRELATE. | | 215.5,310.16,240.4 ETC. | | | | *** IMPORTANT *** | | | | 4) NOTE: PLEASE KNOW, ONE OF THE COPIES | | ARE RETAINED ONCE AGAIN. IF PLANS DO NOT | | COME BACK WITH ALL CORRECTIONS AS NOTED | | ON ALL PREVIOUS REVIEWS, A 4X FEE FOR | | THE PLAN REVIEW PORTION OF THE PERMIT | | FEE WILL BE ASSESSED AS REQUIRED PER FS | | 553.80(2)(B) TO THE DESIGN PROFESSIONAL. | | PLEASE KNOW ALL PLANS RETAINED TO DATE | | WILL BE TURNED OVER THE STATE'S LEGAL | | COUNSEL TO THE FLORIDA BOARD OF | | ARCHITECT'S FOR PEIR REVIEW. PLEASE SEE | | FS 481.221(4) | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
9 |
Status |
F |
Date |
2006-06-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-16 |
Time |
20:53 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-16 |
Time |
20:37 |
Sent To |
PC |
|
Notes |
2006-06-16 00:00:00 | ******* UNSAT 2ND REVIEW OF REVSION *** | | | | | | ** PLEASE SEE NOTES FROM PREVIOUS REVIEW | | AND THIS REVIEW. | | | | 1) NOTE: NOTE #1 NO, PLEASE SEE NUMEROUS | | ITEMS ARE STILL NOT CORRECT. PLEASE SEE | | LOADS EXCEEDING BRKR OCP, BLANK SPACES | | WITH LOADS, 50A BRKRS ON 1HP PUMPS, SEE | | PANEL "B" NOW SHOWS 24 AND 72 A'S ON TOW | | SEPARATE PHASES, #1'S ON RISER FOR | | FEEDERS, #6'S ON PANEL SCHEDULE ETC ETC. | | PLEASE SE MOST OF THESE ARE REDLINED ON | | PLANS. | | 215.5,240.4,240.6,310.16, ETC | | | | ** PREVIOUS NOTE ** | | PLEASE CORRELATE PANEL "B" | | LOADS, SIZE ETC. PLEASE SEE RISER SHOWS | | THIS AS 50A MLO, YET PANEL IS SHOWN AS | | 100A MLO. | | PLEASE SEE LOAD ON PANEL "A" IS SHOWN AT | | 72A'S WHICH FAR EXCEEDS THAT OF A 50A | | BRKR. | | 240.4,310.16,215.5 | | | | 2) NOTE:NOTE #2 NO, SAME NOTE AND SAME | | AS NOTE #1. | | PLEASE SEE WATER HEATER IS NOW REMOVED | | FROM PANEL SCHEDULE YET LOAD IS STILL | | BEING SHOWN IN A BLANK SPACE?? | | PLEASE STILL INDICATE ON SCHEDULE, | | HOWEVER IF IT IS GAS, THEN THERE IS NO | | LOAD. | | | | ** PREVIOUS NOTE** | | PLEASE CORRLEATE ALLLOADS AND | | ITEMS ON LOAD CALCULATIONS WITH THOSE ON | | PANEL SCHEDULES. | | PLEASE SEE THE MICRO/OVEN IS HSOWN WITH | | 40A LOAD ON SCHEDULE, YET CALCS ONLY | | SHOW THIS AS 1.5KW?? | | 215.5 | | PLEASE SEE COOKTOP WITH A HIGH LOAD, ON | | A 1-20A BRKR, YET CALCS SHOWS LOAD AT | | 8KW. CORRELATE OCP, AWG AND LOADS. | | LABEL ACCORDINGLY. | | PLEASE SEE A GAS RANGE IS SHOWN ON LOAD | | CALCS. | | PLEASE SE WATER HEATER IS SHOWN AS GAS | | ON PANEL SCHEDULE, YET LOAD ON SCHEDULE | | DOES NOT CORRELATE WIHT THIS NOR DOES | | THE CALCULATIONS. | | 215.5 | | | | 3) NOTE: NOTE #3, NO, PLEASE SEE | | DEN/STUDY WHICH STILL REQUIRES SOME SORT | | OF LT FIXTURE. | | | | ** PREVIOUS NOTE ** | | PLEASE SEE REDLINED LOCATIONS | | FOR A MIN LT FIXTURE OF SOME TYPE WILL | | BE REQUIRED FOR EGRESS. NFPA-101, 7.8, | | NFPA-70 210.70, NFPA-101 CHAPTER 24 | | | | 4) NOTE: OK. | | | | | | 5) NOTE:NOTE #5 NO, | | | | | | **PREVIOUS NOTE ** | | PLEASE SEE ALL LIGHTING AND | | RECEPT CIRCUITS ON PANEL SCHEDULE SHALL | | BE SPECIFIC TO ROOM/AREA/LOCATION AND | | PURPOSE. | | PLEASE KNOW, IT IS NOT ACCEPTABLE TO | | JUST LIST ALL LIGHTING OR RECEPTS | | WITHOUT WHICH RM ETC THEY ARE FEEDING. | | IE; B-6 MASTER BDRM RECEPTS, FOYER LTS | | ETC. | | | | 6) NOTE:OK | | | | NEW NOTE: | | | | 7) NOTE: PLEASE SEE COPY OF FS | | 553.80(2)(B) IS ATTACHED. IF PLANS COME | | BACK WITH ALL OF THESE ADDRESSED THE | | ABOVE SHALL BE IMPLEMENTED. | | PLEASE SEE THIS WILL BE THE 2ND SET | | RETAINED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
8 |
Status |
F |
Date |
2006-06-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-11 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-11 |
Time |
16:54 |
Sent To |
PC |
|
Notes |
2006-06-11 00:00:00 | ********* UNSAT ************* | | | | 1) NOTE: PLEASE CORRELATE PANEL "B" | | LOADS, SIZE ETC. PLEASE SEE RISER SHOWS | | THIS AS 50A MLO, YET PANEL IS SHOWN AS | | 100A MLO. | | PLEASE SEE LOAD ON PANEL "A" IS SHOWN AT | | 72A'S WHICH FAR EXCEEDS THAT OF A 50A | | BRKR. | | 240.4,310.16,215.5 | | | | 2) NOTE: PLEASE CORRLEATE ALLLOADS AND | | ITEMS ON LOAD CALCULATIONS WITH THOSE ON | | PANEL SCHEDULES. | | PLEASE SEE THE MICRO/OVEN IS HSOWN WITH | | 40A LOAD ON SCHEDULE, YET CALCS ONLY | | SHOW THIS AS 1.5KW?? | | 215.5 | | PLEASE SEE COOKTOP WITH A HIGH LOAD, ON | | A 1-20A BRKR, YET CALCS SHOWS LOAD AT | | 8KW. CORRELATE OCP, AWG AND LOADS. | | LABEL ACCORDINGLY. | | PLEASE SEE A GAS RANGE IS SHOWN ON LOAD | | CALCS. | | PLEASE SE WATER HEATER IS SHOWN AS GAS | | ON PANEL SCHEDULE, YET LOAD ON SCHEDULE | | DOES NOT CORRELATE WIHT THIS NOR DOES | | THE CALCULATIONS. | | 215.5 | | | | 3) NOTE: PLEASE SEE REDLINED LOCATIONS | | FOR A MIN LT FIXTURE OF SOME TYPE WILL | | BE REQUIRED FOR EGRESS. NFPA-101, 7.8, | | NFPA-70 210.70, NFPA-101 CHAPTER 24 | | | | 4) NOTE: PLEASE SEE MANY LOCATIONS | | REDLINED WHERE THE ENTIRE RECEPT IS | | BEING SHOWN AS SWITCHED?? | | PLEASE SEE THIS IS OK, IF INSTALLED THIS | | WAY AS LONG AN ADDITIONAL RECEPT IS | | ADDED TO MEET RECEPT SPACING PER 210.52 | | | | | | 5) NOTE: PLEASE SEE ALL LIGHTING AND | | RECEPT CIRCUITS ON PANEL SCHEDULE SHALL | | BE SPECIFIC TO ROOM/AREA/LOCATION AND | | PURPOSE. | | PLEASE KNOW, IT IS NOT ACCEPTABLE TO | | JUST LIST ALL LIGHTING OR RECEPTS | | WITHOUT WHICH RM ETC THEY ARE FEEDING. | | IE; B-6 MASTER BDRM RECEPTS, FOYER LTS | | ETC. | | | | 6) NOTE: PLEASE VERIFY REDLINED AREA FOR | | POSSIBLE GFI MISSING FOR PENINSULAR. | | 210.52C1-5 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2006-01-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-01-10 |
Time |
16:04 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-01-10 |
Time |
15:47 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-12-23 |
Time |
12:40 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2005-12-23 |
Time |
12:30 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2005-11-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-11-16 |
Time |
19:37 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2005-11-16 |
Time |
19:25 |
Sent To |
|
|
Notes |
2005-11-16 00:00:00 | *********** UNSAT *********** | | | | 1)NOTE: PLEASE SEE NUMEROUS RECEPTS | | MISSING PER 210.52. | | | | 2)NOTE: PLEASE SEE 210.8A6, WHICH | | REQUIRES ALL RECEPTS SERVING KITCHEN | | COUNTERSPACE TO BE GFI/GFI PROTECTED. | | | | 3)NOTE: PLEASE SEE ALL OTHER RECEPTS | | LOCATED WITHIN 6' OF OTHER SINLS OR | | WETBAR LOCATIONS SHALL ALSO BE GFI/GFI | | PROTECTED. | | 210.8A7 | | | | 4)NOTE: PLEASE SEE MISSING RECEPTS PER | | 210.52H? | | | | 5)NOTE: PLEASE SEE MISSING GFI RECEPTS | | ALONG KITCHEN COUNTERSPACE, ISLAND ETC. | | 210.52C1-C5 | | | | 6)NOTE: PLEASE SEE CLARIFY RISER DIAGRAM | | GROUNDING ELECTRODE SYSTEM FROM MAIN | | DISCONNECT AND THEN ALSO SHOWS A | | GROUNDING ELECTRODE OF A "STEEL PIPE"?? | | FROM METER. | | PLEASE SEE 250.50, 250.6 AND 250.24 FOR | | LOCATION OF GROUNDING ELECTRODE | | CONDUCTOR, GROUNDING ELECTRODES ETC. | | PLEASE VERIFY FIELD INSTALLATION. | | | | 7)NOTE: PLEASE CORRELATE LOAD | | CALCULATIONS AND PANEL SCHEDULE FOR | | COOK-TOP, RANGE, AND OVENS. | | PLEASE SEE GAS, ELEC OR NOT SHOWN.?? | | | | 8)NOTE: PLEASE VERIFY 1HP PUMP WHICH | | SHOWS 40A OCP?? AND #8 AWG?? | | THIS DOES NOT SEEM TO BE CORRECT, PLEASE | | SEE 430 FOR MAX OCP AND CODE LTR AND | | TYPES OF MOTORS. | | | | 9)NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | PLEASE REVISE LOAD CALCUALTIONS. | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2005-03-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-03-03 |
Time |
15:15 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-03-03 |
Time |
11:28 |
Sent To |
P |
|
Notes |
2005-03-03 00:00:00 | ******** PROVISO/NOTES *********** | | | | | | 1)NOTE: PLEASE SEE NOTE #5 FROM PREVIOUS | | REVIEW. | | PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | | | PLEASE REVISE ALONG WITH ANY OTHER | | CHANGES BEFORE ROUGH ELECTRICAL | | INSPECTION. | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] | | PLEASE SEE 210.52D FOR BATH RECEPTS | | PLEASE SEE 210.52 MISSING BEDRM RECEPTS. | | | | BOTH OF THESE ITEMS REDLINED ON PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2005-02-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-02-08 |
Time |
14:17 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2005-02-08 |
Time |
13:55 |
Sent To |
P |
|
Notes |
2005-02-08 00:00:00 | ******* UNSAT ********* | | | | 1)NOTE: PLEASE SEE PREVIOUS NOTES WHICH | | WERE SET UP AS A "PROVISO" AND PLANS | | WERE PASSED AND STAMPED. HOWEVER NEW | | ELECTRICAL SHEETS ARE NOW SUBMITTED | | WITHOUT ANY CORRECTIONS MADE TO PREVIOUS | | PLANS? | | IT WAS REQUESTED ON PREVIOUS REVIEW FOR | | THESE CHANGES TO BE MADE, YET NO CHANGES | | TO PLANS COULD BE FOUND.?? | | | | 2)NOTE: PLEASE SEE LOCATION OF PANEL "B" | | IS NOT SHOWN ON PLANS?? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-08-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-23 |
Time |
16:48 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2004-08-23 |
Time |
16:48 |
Sent To |
M |
|
Notes |
2004-08-23 00:00:00 | ******** PROVISO/REVISION *********** | | | | 1)NOTE: PLEASE SEE THERE ARE NUMEROUS | | REFERENCES ON ELECTRICAL PLANS WHICH | | REF FBC AND ARTS:. PLEASE ADJUST TO NEC. | | | | 2)NOTE: PLEASE SEE FRIG IS NOW SHOWN AS | | A 2P20A FEED ON A SINGLE POLE SPACE. | | | | 3)NOTE: PLEASE ANY HANDDRAWN CHANGES TO | | PLANS MUST BE DONE BY ARCH OF RECORD. | | | | 4)NOTE: PLEASE SEE RISER DIAGRAM SHOWS | | PVC AND GR CONDUIT. | | | | 5)NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW BEFORE ROUGH ELECTRICAL INSPECT- | | -ION IS CALLED IN. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | NOT ALL NOTES FROM FIRST REVIEW WERE | | ADDRESSED. | | SEE PROVISO ATTACHED TO PLANS. | | FEES WILL BE DUE FOR REVISION. | | IF PLANS COME BACK FOR ANY COMMENTS BY | | OTHER TRADES , PLEASE ADDRESS COMMENTS | | AT THIS TIME TO AVOID REVISIONS AT LATER | | DATE. | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-04-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-18 |
Time |
12:19 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2004-04-26 |
Time |
09:09 |
Sent To |
M |
|
Notes |
2004-04-26 00:00:00 | ********** UNSAT *********** | | | | 1)NOTE: PLEASE SEE NOTE:9 MENTIONS THAT | | ALL WIRE TO BEA MIN OF #12, YET PANELS | | SHOWS #14. PLEASE CORRELATE. | | | | 2)NOTE: PLEASE SEE ALL NEC ARTS REFER- | | -ENCED ON PLANS MENTIONS PER FBC. | | THESE ARE 2002 NEC CODES. | | | | 3)NOTE: PLEASE SHOW GROUNDING ELECTRODE | | SYSTEM TO BLDG/FOOTER STEEEL, COLD | | WATER. 250.50 | | | | 4)NOTE: PLEASE SEE OCP ON PANEL SCHEDULE | | -S FOR ALL 220V ITEMS. THESE APPEAR TO | | BE MISPRINTS AND SHOW ALL AS 1-POLE | | BRKRS. | | | | 5)NOTE: PLEASE SEE PANEL SCHEDULE AND | | RISER DIAGRAM. SHOWS 3#-? FOR CONDUCTORS | | TO SUB PANEL. PLEASE VERIFY AWG AND # OF | | CONDUCTORS. | | 310.16, 215.5 | | | | 6)NOTE: PLEASE SEE NEC 220. PLEASE SHOW | | LOAD CALCULATIONS AS SET FORTH IN 220 | | FOR MIN LOADS ETC. LOAD CALCULATIONS | | NEED TO BE SHOWN. 215.5 | | | | 7)NOTE: PLEASE SEE NFPA-72 8-1.4.2 FOR | | SD INSTALLATION. SD SHOWN OUTSIDE BEDRM | | #3/ KITCHEN MAY NEED TO BE MOVED. | | THIS IS JUST AN FYI. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2006-06-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-30 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-30 |
Time |
16:30 |
Sent To |
E |
|
Notes |
2006-06-30 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2006-06-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-16 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-16 |
Time |
15:20 |
Sent To |
E |
|
Notes |
2006-06-16 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2006-06-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-08 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-08 |
Time |
13:31 |
Sent To |
E |
|
Notes |
2006-06-08 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2006-03-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-03 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-03 |
Time |
12:13 |
Sent To |
P |
|
Notes |
2006-03-03 00:00:00 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2006-01-10 |
|
|
Cont ID |
|
Sent By |
ptjomsto |
Date |
2006-01-10 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
ptjomsto |
Date |
2006-01-10 |
Time |
13:14 |
Sent To |
|
|
Notes |
2006-01-10 00:00:00 | REV GIVEN TO BILL TROBAUGH |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2005-12-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-01 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-01 |
Time |
16:17 |
Sent To |
E |
|
Notes |
2005-12-01 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2005-11-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-14 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-14 |
Time |
14:56 |
Sent To |
E |
|
Notes |
2005-11-14 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2005-04-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-29 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-29 |
Time |
11:14 |
Sent To |
P |
|
Notes |
2005-04-29 00:00:00 | TO "KSTEVENS" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-03-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-16 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-16 |
Time |
14:20 |
Sent To |
M |
|
Notes |
2005-03-16 00:00:00 | TO "SFR""M" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2005-03-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-02 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-02 |
Time |
14:38 |
Sent To |
E |
|
Notes |
2005-03-02 00:00:00 | TO DPALMER DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-02-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-07 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-02-07 |
Time |
08:55 |
Sent To |
E |
|
Notes |
2005-02-07 00:00:00 | TO D.PALMER DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-08-18 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-18 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-18 |
Time |
12:18 |
Sent To |
E |
|
Notes |
2004-08-18 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-04-22 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-04-22 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2004-04-22 |
Time |
14:03 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-05-05 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-04-21 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-20 |
Time |
12:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2005-03-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-03-23 |
Time |
14:00 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2005-03-23 |
Time |
14:00 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2005-02-17 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-02-17 |
Time |
08:35 |
Rev Time |
1.25 |
Received By |
prafter |
Date |
2005-02-17 |
Time |
08:35 |
Sent To |
B |
|
Notes |
2005-02-17 00:00:00 | THIRD MECH. REVIEW: | | | | 1. RETURN AIR DUCT FROM BALLERY | | REFLECTS 16" THEN CHANGES TO 10" DUCT | | RETURNING TO A.H.U.#1 . | | PLEASE CORRECT. | | 2. RETURN AIR DUCT FROM BEDROOM #3 NOT | | SIZED. | | 3. RETURN AIR DUCT FROM BEDROOM #2 AND | | #3 REFLECT 10" RETURNING TO A.H.U.#1. | | | | PLEASE CORRECT R/A DUCT SIZE. | | | | 4. AUXILIARY DRAIN PAN WITH OVERFLOW | | PROTECTION REQUIED PER 2001 FBC/M | | 307.2.3 FOR A.H.U. . | | | | PAT RAFTER 561/805/6728 . PLEASE CALL | | IF THEAR ENY QUESTION. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2004-08-27 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-08-27 |
Time |
16:38 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2004-08-27 |
Time |
16:38 |
Sent To |
B |
|
Notes |
2004-08-27 00:00:00 | DENIED:2ND REQUEST | | PLEASE PROVIDE MANUAL J CALCULATIONS | | IN ACCORDANCE WITH 2001 FBC CHAPTER 13 | | SUB-SECTION 607.1.ABC.1. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-04-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-23 |
Time |
17:12 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2004-04-28 |
Time |
09:49 |
Sent To |
P |
|
Notes |
2004-04-28 00:00:00 | DENIED: | | PLEASE PROVIDE THE FOLLOWING: | | | | 1.ENERGY & MANUAL J CALCULATIONS PER | | 2001 FBC CHAPTER 13, SUB-CHAPTER 6. | | | | 2.AUXILIARY DRAIN PAN WITH OVERFLOW | | PROTECTION REQUIRED PER 2001 FBC(M) | | 307.2.3. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2006-03-09 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-03-09 |
Time |
07:22 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2006-03-09 |
Time |
07:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2005-05-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-12-23 |
Time |
12:40 |
Rev Time |
0.75 |
Received By |
jleech |
Date |
2005-05-14 |
Time |
10:19 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2005-04-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-04-02 |
Time |
11:51 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2005-04-02 |
Time |
11:51 |
Sent To |
B |
|
Notes |
2005-04-02 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1) SHT P-2 SANITARY RISER DIAGRAM DOES | | NOT MEET THE CODE REQUIREMENTS: | | A) SHOW ALL PIPE SIZES. SECTIONS | | 104.2.1. AND TABLE 709.1 | | B) RISER DIAGRAM INDICATES 2" PIPE TO | | WATER CLOSETS. PER TABLE 709.1 FOOTNOTE | | "D" TRAP SIZE SHALL BE CONSISTANT WITH | | FIXTURE OUTLET SIZE. MANUF. | | SPECIFICATION SHEETS WILL BE REQUIRED AT | | THE TIME OF PLUMBING FINAL SHOWING THE | | OUTLET SIZE OF WATER CLOSETS. | | C) WHITE OUT IS NOT APPROVED FOR SIGNED | | SEALED AND DATED PLANS. SECTION | | 104.2.1.3. | | D) FITTING AT JUNCTION OF W/M AND | | UTILITY SINK DOES NOT COMPLY WITH | | SECTION 706.3. FITTING SHALL GUIDE | | SEWAGE IN DIRECTION OF FLOW. | | E) VENT FOR MASTER BATH WATER CLOSET | | APPEARS TO BE A DRY HORIZONTAL VENT | | WHICH IS NOT APPROVED PER SECTIONS 905.3 | | AND 905.4. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2005-03-11 |
|
|
Cont ID |
|
Sent By |
gsalfeld |
Date |
2005-03-11 |
Time |
14:38 |
Rev Time |
1.00 |
Received By |
gsalfeld |
Date |
2005-03-11 |
Time |
14:38 |
Sent To |
|
|
Notes |
2005-03-11 00:00:00 | 3/11/05 DENIED GS | | | | 1-THE ISLAND SINK IN THE KITCHEN SHALL | | BE SHOWN ON THE SANITARY RISER DIAGRAM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2005-02-16 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-02-16 |
Time |
10:57 |
Rev Time |
0.60 |
Received By |
kstevens |
Date |
2005-02-16 |
Time |
10:56 |
Sent To |
M |
|
Notes |
2005-02-16 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1) SHT P-2 SANITARY RISER DIAGRAM DOES | | NOT REFLECT THE FLOOR PLAN, DOES NOT | | MEET CODE REQUIREMENTS, NOR IS IT DRAWN | | IN A CLEAR ISOMETRIC FORM. | | A) SEE EXAMPLE ON SHT P-2 IN RED INK | | THAT SHOWS PIPING THAT IS DRAWN IN THE | | VERTICLE INDICATES PIPING TO A SECOND | | FLOOR. AND SEE EXAMPLE OF REMDEDY FOR | | THE W/M, UTILITY SINK. | | B) ISOMETRIC IS A REVERSE OF THE FLOOR | | PLAN. SECTION 104.2.1. | | C) BATH #3 IS MISSING THE TUB ON THE | | SANT. RISER THAT IS SHOWN ON THE FLOOR | | PLAN. SECTION 104.2.1. | | D) UTILITY SINK IS NOT VENTED. SECTION | | 901.2.1. | | E) WASH MACHINE REQUIRES A MIN. 2' | | STANDPIPE, AND A CLEANOUT 4' ABOVE THE | | FLOOR. SECTIONS 1002.1 & 708.10. | | F) TRAPS ARE REQUIRED ON ALL SHOWERS, | | TUBS, AND BIDET. SECTION 1002.1. | | G) THE AIR ADMITTENCE VALVE FOR THE | | ISLAND SINK IN THE KITCHEN SHALL BE | | SHOWN ON THE SANITARY RISER DIAGRA. | | SECTION 104.2.1. & SECTION 901.2.1. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-05-03 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-04-28 |
Time |
10:02 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2004-05-03 |
Time |
20:04 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-04-21 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-20 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-04-21 |
Time |
11:32 |
Sent To |
I |
|
Notes |
|
|