Plan Review Details - Permit 04041341
Plan Review Stops For Permit 04041341
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-05-17 Cont ID  
Sent By alange Date 2005-05-17 Time 11:18 Rev Time 0.50
Received By alange Date 2005-05-17 Time 11:16 Sent To  
Notes
2005-05-17 00:00:00STAMPED AND ISSUED

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-04-25 Cont ID  
Sent By alange Date 2005-04-25 Time 10:16 Rev Time 0.50
Received By alange Date 2005-04-25 Time 10:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-02-18 Cont ID  
Sent By alange Date 2005-02-18 Time 15:24 Rev Time 1.00
Received By alange Date 2005-02-18 Time 15:24 Sent To  
Notes
2005-02-18 00:00:00DENIED
  
 ITEMS FROM LAST REVIEW:
  
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 5.WINDOW AND DOOR BUCKS SHALL COMPLY
 WITH FBC 1707.4.4.2BUCKS SHALL EXTEND
 BEYOND THE INTERIOR FACE OF THE WINDOW
 AND DOOR FRAME SUCH THAT FULL SUPPORT
 OF THE FRAME IS PROVIDED.SHOW DETAIL.
  
 6.SUBMIT COPY OF THE COVENANTS THAT
 HAVE BEEN AMENDED AND RECORDED WITH
 PALM BEACH COUNTY TO CREATE AN
 EMERGENCY EGRESS THROUGH THE ADJOINING
 LOT ON THE ZERO LOT LINE SIDE OF THE
 STRUCTURE.
 1001.1.3/ 1005.4 ZERO LOT LINE
 EGRESS:WHEN ACCESS TO OR FROM A RE-
 QUIRED EMERGENCY ESCAPE AND RESCUE OPEN-
 ING OF A STRUCTURE TO THE PUBLIC WAY,
 REQUIRES TRANSVERSING A PROPERTY
 (ADJOINING LOT) THAT IS NOT PART OF THE
 ONE WHICH THE STRUCTURE IS LOCATED, AN
 EGRESS EASEMENT THROUGH THE ADJOINING
 PROPERTY IS REQUIRED AND SHALL BE RECORD
 ED IN THE COUNTY RECORDS. THIS EASEMENT
 SHALL BE A MINIMUM OF 3' WIDE AND NOTH-
 ING SHALL BE PLACED WITHIN THE EASEMENT
 AREA WHICH WOULD BLOCK ACCESS TO THE
 EASEMENT AND OR IMPEDE EMERGENCY EGRESS
 FROM THE RESCUE OPENING TO THE PUBLIC
 WAY. NO LANDSCAPING, FENCES OR OTHER
 IMPEDIMENTS SHALL BE INSTALLED IN THIS
 EASEMENT.
  
 NEW COMMENT:GARDEN COURT TABLE 6OO
 CALCULATIONS ARE INCORRECT.
 TOTAL AREA 9' X 12' = 108SQ. FT.
 OPENINGS 3 X 7 = 21
 9 X .75 = 6.75 TOTAL 27.75SQ FT.
 PERCENTAGE OF OPENINGS IS TOO HIGH.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 ART LANGE
 BUILDING PLAN REVIEW
 TEL: (561)805-6672
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-09-14 Cont ID  
Sent By alange Date 2004-09-14 Time 09:03 Rev Time 1.50
Received By alange Date 2004-09-14 Time 09:03 Sent To  
Notes
2004-09-14 00:00:00DENIED
  
 ITEMS FROM LAST REVIEW:
  
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT 2 SIGNED COPIES OF ENERGY
 CALCS.
  
 5.WINDOW AND DOOR BUCKS SHALL COMPLY
 WITH FBC 1707.4.4.2BUCKS SHALL EXTEND
 BEYOND THE INTERIOR FACE OF THE WINDOW
 AND DOOR FRAME SUCH THAT FULL SUPPORT
 OF THE FRAME IS PROVIDED.SHOW DETAIL.
  
 6.SUBMIT COPY OF THE COVENANTS THAT
 HAVE BEEN AMENDED AND RECORDED WITH
 PALM BEACH COUNTY TO CREATE AN
 EMERGENCY EGRESS THROUGH THE ADJOINING
 LOT ON THE ZERO LOT LINE SIDE OF THE
 STRUCTURE.
 1001.1.3/ 1005.4 ZERO LOT LINE
 EGRESS:WHEN ACCESS TO OR FROM A RE-
 QUIRED EMERGENCY ESCAPE AND RESCUE OPEN-
 ING OF A STRUCTURE TO THE PUBLIC WAY,
 REQUIRES TRANSVERSING A PROPERTY
 (ADJOINING LOT) THAT IS NOT PART OF THE
 ONE WHICH THE STRUCTURE IS LOCATED, AN
 EGRESS EASEMENT THROUGH THE ADJOINING
 PROPERTY IS REQUIRED AND SHALL BE RECORD
 ED IN THE COUNTY RECORDS. THIS EASEMENT
 SHALL BE A MINIMUM OF 3' WIDE AND NOTH-
 ING SHALL BE PLACED WITHIN THE EASEMENT
 AREA WHICH WOULD BLOCK ACCESS TO THE
 EASEMENT AND OR IMPEDE EMERGENCY EGRESS
 FROM THE RESCUE OPENING TO THE PUBLIC
 WAY. NO LANDSCAPING, FENCES OR OTHER
 IMPEDIMENTS SHALL BE INSTALLED IN THIS
 EASEMENT.
  
 7.BUILDING VALUE TO LOW.ADDITIONAL
 PERMIT FEES OF $693.74 ARE DUE.
  
 NEW:
 A.SOIL REPORT SUBMITTED ARE NOT SIGNED
 AND SEALED.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 ART LANGE
 BUILDING PLAN REVIEW
 TEL: (561)805-6672
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-05-05 Cont ID  
Sent By pkrauss Date 2004-08-27 Time 16:39 Rev Time 2.50
Received By alange Date 2004-05-05 Time 15:22 Sent To  
Notes
2004-05-05 00:00:00DENIED
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT 2 COPIES OF ENERGY CALCS.
  
 4.PRODUCT APPROVALS SUBMITTED ARE NOT
 COMPLETE, SUBMIT 2 COPIES FOR ONLY
 PRODUCTS USED ON THIS PROJECT.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATIONPLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
 ATTACH APPROVALS TO YOUR NOA'S
  
 5.WINDOW AND DOOR BUCKS SHALL COMPLY
 WITH FBC 1707.4.4.2BUCKS SHALL EXTEND
 BEYOND THE INTERIOR FACE OF THE WINDOW
 OR DOOR FRAME SUCH THAT FULL SUPPORT OF
 THE FRAME IS PROVIDED.SHOW DETAIL.
  
 6. SUBMIT A COPY OF THE COVENANTS THAT
 HAS BEEN AMENDED AND RECORDED WITH PALM
 BEACH COUNTY TO CREATE AN EMERGENCY
 EGRESS THROUGH THE ADJOINING LOT ON THE
 ZERO LOT LINE SIDE OF THE STRUCTURE.
 1001.1.3/ 1005.4 ZERO LOT LINE
 EGRESS:WHEN ACCESS TO OR FROM A RE-
 QUIRED EMERGENCY ESCAPE AND RESCUE
 OPEN-ING OF A STRUCTURE TO THE PUBLIC
 WAY,
 REQUIRES TRANSVERSING A PROPERTY
 (ADJOINING LOT) THAT IS NOT PART OF THE
 ONE WHICH THE STRUCTURE IS LOCATED, AN
 EGRESS EASEMENT THROUGH THE ADJOINING
 PROPERTY IS REQUIRED AND SHALL BE
 RECORDED IN THE COUNTY RECORDS. THIS
 EASEMENT SHALL BE A MINIMUM OF 3' WIDE
 AND NOTH- ING SHALL BE PLACED WITHIN
 THE EASEMENT AREA WHICH WOULD BLOCK
 ACCESS TO THE
 EASEMENT AND OR IMPEDE EMERGENCY EGRESS
 FROM THE RESCUE OPENING TO THE PUBLIC
 WAY. NO LANDSCAPING, FENCES OR OTHER
 IMPEDIMENTS SHALL BE INSTALLED IN THIS
 EASEMENT.
  
 7.BUIDING VALUE OF $220,000 IS TO LOW
 BASED UPON SBCCI BUILDING VALUATION
 DATATHE VALUATION HAS BEEN REVISED TO
 $288,687.ADDITIONAL PERMIT FEES
 ARE DUE.
  
 8.SQUARE FOOTAGE ON APPLICATION WAS
 NOT ACCURATE AND HAS BEEN REVISED.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 11 Status P Date 2006-07-06 Cont ID  
Sent By dpalmer Date 2006-07-06 Time 16:49 Rev Time 0.00
Received By dpalmer Date 2006-07-06 Time 16:49 Sent To PC
Notes
2006-07-06 00:00:00REDLINED POOL PANEL LOCATION.
  
 MANY CIRCUITS SHOWING CONDUCTOR SIZES
 LARGER THAN NEEDED, HOWEVER THIS IS OK.
 IF SHOWN ON PLANS THIS WAY, THIS IS WHAT
 SHOULD BE INSTALLED.

Review Stop E ELECTRICAL
Rev No 10 Status F Date 2006-07-03 Cont ID  
Sent By dpalmer Date 2006-07-03 Time 08:15 Rev Time 0.00
Received By dpalmer Date 2006-07-03 Time 07:40 Sent To PC
Notes
2006-07-03 00:00:00******** UNSAT ***********
  
 1) NOTE: PLEASE SEE NUMEROUS ITEMS ON
 PANEL SCHEDULE AND LOCD CALCULATIONS
 WHICH STILL DO NOT CORRELATE.
 PLEASE SEE AHU'S, SPA, POOL, DISHWASHER
 (S), LAUNDRY/WASHER, ETC ETC.
 PLEASE SEE PANELS STILL DO NOT
 CORRELATE.
 215.5,240.4,310.16, ( 2002 NEC)
  
 2) NOTE: PLEASE SHOW EACH PANEL WITH
 CORRECT LOADS AND LOAD CALCULATIONS PER
 NEC 220.
 PLEASE SEE THE LOADS FOR "B".
  
 3) NOTE: PLEASE SEE MIN LT FIX REQUIRED
 FOR EGRESS. LS 101 7.8, 210.70
  
 4) NOTE: PLEASE SEE THAT THE RISER AND
 PANELS STILL DO NOT CORRELATE.
 LOADS DO NOT CORRELATE.
 215.5,310.16,240.4 ETC.
  
 *** IMPORTANT ***
  
 4) NOTE: PLEASE KNOW, ONE OF THE COPIES
 ARE RETAINED ONCE AGAIN. IF PLANS DO NOT
 COME BACK WITH ALL CORRECTIONS AS NOTED
 ON ALL PREVIOUS REVIEWS, A 4X FEE FOR
 THE PLAN REVIEW PORTION OF THE PERMIT
 FEE WILL BE ASSESSED AS REQUIRED PER FS
 553.80(2)(B) TO THE DESIGN PROFESSIONAL.
 PLEASE KNOW ALL PLANS RETAINED TO DATE
 WILL BE TURNED OVER THE STATE'S LEGAL
 COUNSEL TO THE FLORIDA BOARD OF
 ARCHITECT'S FOR PEIR REVIEW. PLEASE SEE
 FS 481.221(4)
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 9 Status F Date 2006-06-16 Cont ID  
Sent By dpalmer Date 2006-06-16 Time 20:53 Rev Time 0.00
Received By dpalmer Date 2006-06-16 Time 20:37 Sent To PC
Notes
2006-06-16 00:00:00******* UNSAT 2ND REVIEW OF REVSION ***
  
  
 ** PLEASE SEE NOTES FROM PREVIOUS REVIEW
 AND THIS REVIEW.
  
 1) NOTE: NOTE #1 NO, PLEASE SEE NUMEROUS
 ITEMS ARE STILL NOT CORRECT. PLEASE SEE
 LOADS EXCEEDING BRKR OCP, BLANK SPACES
 WITH LOADS, 50A BRKRS ON 1HP PUMPS, SEE
 PANEL "B" NOW SHOWS 24 AND 72 A'S ON TOW
 SEPARATE PHASES, #1'S ON RISER FOR
 FEEDERS, #6'S ON PANEL SCHEDULE ETC ETC.
 PLEASE SE MOST OF THESE ARE REDLINED ON
 PLANS.
 215.5,240.4,240.6,310.16, ETC
  
 ** PREVIOUS NOTE **
 PLEASE CORRELATE PANEL "B"
 LOADS, SIZE ETC. PLEASE SEE RISER SHOWS
 THIS AS 50A MLO, YET PANEL IS SHOWN AS
 100A MLO.
 PLEASE SEE LOAD ON PANEL "A" IS SHOWN AT
 72A'S WHICH FAR EXCEEDS THAT OF A 50A
 BRKR.
 240.4,310.16,215.5
  
 2) NOTE:NOTE #2 NO, SAME NOTE AND SAME
 AS NOTE #1.
 PLEASE SEE WATER HEATER IS NOW REMOVED
 FROM PANEL SCHEDULE YET LOAD IS STILL
 BEING SHOWN IN A BLANK SPACE??
 PLEASE STILL INDICATE ON SCHEDULE,
 HOWEVER IF IT IS GAS, THEN THERE IS NO
 LOAD.
  
 ** PREVIOUS NOTE**
 PLEASE CORRLEATE ALLLOADS AND
 ITEMS ON LOAD CALCULATIONS WITH THOSE ON
 PANEL SCHEDULES.
 PLEASE SEE THE MICRO/OVEN IS HSOWN WITH
 40A LOAD ON SCHEDULE, YET CALCS ONLY
 SHOW THIS AS 1.5KW??
 215.5
 PLEASE SEE COOKTOP WITH A HIGH LOAD, ON
 A 1-20A BRKR, YET CALCS SHOWS LOAD AT
 8KW. CORRELATE OCP, AWG AND LOADS.
 LABEL ACCORDINGLY.
 PLEASE SEE A GAS RANGE IS SHOWN ON LOAD
 CALCS.
 PLEASE SE WATER HEATER IS SHOWN AS GAS
 ON PANEL SCHEDULE, YET LOAD ON SCHEDULE
 DOES NOT CORRELATE WIHT THIS NOR DOES
 THE CALCULATIONS.
 215.5
  
 3) NOTE: NOTE #3, NO, PLEASE SEE
 DEN/STUDY WHICH STILL REQUIRES SOME SORT
 OF LT FIXTURE.
  
 ** PREVIOUS NOTE **
 PLEASE SEE REDLINED LOCATIONS
 FOR A MIN LT FIXTURE OF SOME TYPE WILL
 BE REQUIRED FOR EGRESS. NFPA-101, 7.8,
 NFPA-70 210.70, NFPA-101 CHAPTER 24
  
 4) NOTE: OK.
  
  
 5) NOTE:NOTE #5 NO,
  
  
 **PREVIOUS NOTE **
 PLEASE SEE ALL LIGHTING AND
 RECEPT CIRCUITS ON PANEL SCHEDULE SHALL
 BE SPECIFIC TO ROOM/AREA/LOCATION AND
 PURPOSE.
 PLEASE KNOW, IT IS NOT ACCEPTABLE TO
 JUST LIST ALL LIGHTING OR RECEPTS
 WITHOUT WHICH RM ETC THEY ARE FEEDING.
 IE; B-6 MASTER BDRM RECEPTS, FOYER LTS
 ETC.
  
 6) NOTE:OK
  
 NEW NOTE:
  
 7) NOTE: PLEASE SEE COPY OF FS
 553.80(2)(B) IS ATTACHED. IF PLANS COME
 BACK WITH ALL OF THESE ADDRESSED THE
 ABOVE SHALL BE IMPLEMENTED.
 PLEASE SEE THIS WILL BE THE 2ND SET
 RETAINED.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 8 Status F Date 2006-06-11 Cont ID  
Sent By dpalmer Date 2006-06-11 Time 17:03 Rev Time 0.00
Received By dpalmer Date 2006-06-11 Time 16:54 Sent To PC
Notes
2006-06-11 00:00:00********* UNSAT *************
  
 1) NOTE: PLEASE CORRELATE PANEL "B"
 LOADS, SIZE ETC. PLEASE SEE RISER SHOWS
 THIS AS 50A MLO, YET PANEL IS SHOWN AS
 100A MLO.
 PLEASE SEE LOAD ON PANEL "A" IS SHOWN AT
 72A'S WHICH FAR EXCEEDS THAT OF A 50A
 BRKR.
 240.4,310.16,215.5
  
 2) NOTE: PLEASE CORRLEATE ALLLOADS AND
 ITEMS ON LOAD CALCULATIONS WITH THOSE ON
 PANEL SCHEDULES.
 PLEASE SEE THE MICRO/OVEN IS HSOWN WITH
 40A LOAD ON SCHEDULE, YET CALCS ONLY
 SHOW THIS AS 1.5KW??
 215.5
 PLEASE SEE COOKTOP WITH A HIGH LOAD, ON
 A 1-20A BRKR, YET CALCS SHOWS LOAD AT
 8KW. CORRELATE OCP, AWG AND LOADS.
 LABEL ACCORDINGLY.
 PLEASE SEE A GAS RANGE IS SHOWN ON LOAD
 CALCS.
 PLEASE SE WATER HEATER IS SHOWN AS GAS
 ON PANEL SCHEDULE, YET LOAD ON SCHEDULE
 DOES NOT CORRELATE WIHT THIS NOR DOES
 THE CALCULATIONS.
 215.5
  
 3) NOTE: PLEASE SEE REDLINED LOCATIONS
 FOR A MIN LT FIXTURE OF SOME TYPE WILL
 BE REQUIRED FOR EGRESS. NFPA-101, 7.8,
 NFPA-70 210.70, NFPA-101 CHAPTER 24
  
 4) NOTE: PLEASE SEE MANY LOCATIONS
 REDLINED WHERE THE ENTIRE RECEPT IS
 BEING SHOWN AS SWITCHED??
 PLEASE SEE THIS IS OK, IF INSTALLED THIS
 WAY AS LONG AN ADDITIONAL RECEPT IS
 ADDED TO MEET RECEPT SPACING PER 210.52
  
  
 5) NOTE: PLEASE SEE ALL LIGHTING AND
 RECEPT CIRCUITS ON PANEL SCHEDULE SHALL
 BE SPECIFIC TO ROOM/AREA/LOCATION AND
 PURPOSE.
 PLEASE KNOW, IT IS NOT ACCEPTABLE TO
 JUST LIST ALL LIGHTING OR RECEPTS
 WITHOUT WHICH RM ETC THEY ARE FEEDING.
 IE; B-6 MASTER BDRM RECEPTS, FOYER LTS
 ETC.
  
 6) NOTE: PLEASE VERIFY REDLINED AREA FOR
 POSSIBLE GFI MISSING FOR PENINSULAR.
 210.52C1-5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2006-01-10 Cont ID  
Sent By btrobaug Date 2006-01-10 Time 16:04 Rev Time 0.50
Received By btrobaug Date 2006-01-10 Time 15:47 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2005-12-23 Cont ID  
Sent By btrobaug Date 2005-12-23 Time 12:40 Rev Time 0.33
Received By btrobaug Date 2005-12-23 Time 12:30 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2005-11-16 Cont ID  
Sent By dpalmer Date 2005-11-16 Time 19:37 Rev Time 0.50
Received By dpalmer Date 2005-11-16 Time 19:25 Sent To  
Notes
2005-11-16 00:00:00*********** UNSAT ***********
  
 1)NOTE: PLEASE SEE NUMEROUS RECEPTS
 MISSING PER 210.52.
  
 2)NOTE: PLEASE SEE 210.8A6, WHICH
 REQUIRES ALL RECEPTS SERVING KITCHEN
 COUNTERSPACE TO BE GFI/GFI PROTECTED.
  
 3)NOTE: PLEASE SEE ALL OTHER RECEPTS
 LOCATED WITHIN 6' OF OTHER SINLS OR
 WETBAR LOCATIONS SHALL ALSO BE GFI/GFI
 PROTECTED.
 210.8A7
  
 4)NOTE: PLEASE SEE MISSING RECEPTS PER
 210.52H?
  
 5)NOTE: PLEASE SEE MISSING GFI RECEPTS
 ALONG KITCHEN COUNTERSPACE, ISLAND ETC.
 210.52C1-C5
  
 6)NOTE: PLEASE SEE CLARIFY RISER DIAGRAM
 GROUNDING ELECTRODE SYSTEM FROM MAIN
 DISCONNECT AND THEN ALSO SHOWS A
 GROUNDING ELECTRODE OF A "STEEL PIPE"??
 FROM METER.
 PLEASE SEE 250.50, 250.6 AND 250.24 FOR
 LOCATION OF GROUNDING ELECTRODE
 CONDUCTOR, GROUNDING ELECTRODES ETC.
 PLEASE VERIFY FIELD INSTALLATION.
  
 7)NOTE: PLEASE CORRELATE LOAD
 CALCULATIONS AND PANEL SCHEDULE FOR
 COOK-TOP, RANGE, AND OVENS.
 PLEASE SEE GAS, ELEC OR NOT SHOWN.??
  
 8)NOTE: PLEASE VERIFY 1HP PUMP WHICH
 SHOWS 40A OCP?? AND #8 AWG??
 THIS DOES NOT SEEM TO BE CORRECT, PLEASE
 SEE 430 FOR MAX OCP AND CODE LTR AND
 TYPES OF MOTORS.
  
 9)NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
 PLEASE REVISE LOAD CALCUALTIONS.
  
 ** PLEASE SUBMIT THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-03-03 Cont ID  
Sent By dpalmer Date 2005-03-03 Time 15:15 Rev Time 0.30
Received By dpalmer Date 2005-03-03 Time 11:28 Sent To P
Notes
2005-03-03 00:00:00******** PROVISO/NOTES ***********
  
  
 1)NOTE: PLEASE SEE NOTE #5 FROM PREVIOUS
 REVIEW.
 PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 PLEASE REVISE ALONG WITH ANY OTHER
 CHANGES BEFORE ROUGH ELECTRICAL
 INSPECTION.
  
 IF THERE ARE ANY QUESTIONS, PLEASE DO
 NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
 PLEASE SEE 210.52D FOR BATH RECEPTS
 PLEASE SEE 210.52 MISSING BEDRM RECEPTS.
  
 BOTH OF THESE ITEMS REDLINED ON PLANS.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2005-02-08 Cont ID  
Sent By dpalmer Date 2005-02-08 Time 14:17 Rev Time 0.25
Received By dpalmer Date 2005-02-08 Time 13:55 Sent To P
Notes
2005-02-08 00:00:00******* UNSAT *********
  
 1)NOTE: PLEASE SEE PREVIOUS NOTES WHICH
 WERE SET UP AS A "PROVISO" AND PLANS
 WERE PASSED AND STAMPED. HOWEVER NEW
 ELECTRICAL SHEETS ARE NOW SUBMITTED
 WITHOUT ANY CORRECTIONS MADE TO PREVIOUS
 PLANS?
 IT WAS REQUESTED ON PREVIOUS REVIEW FOR
 THESE CHANGES TO BE MADE, YET NO CHANGES
 TO PLANS COULD BE FOUND.??
  
 2)NOTE: PLEASE SEE LOCATION OF PANEL "B"
 IS NOT SHOWN ON PLANS??
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-08-23 Cont ID  
Sent By dpalmer Date 2004-08-23 Time 16:48 Rev Time 0.75
Received By dpalmer Date 2004-08-23 Time 16:48 Sent To M
Notes
2004-08-23 00:00:00******** PROVISO/REVISION ***********
  
 1)NOTE: PLEASE SEE THERE ARE NUMEROUS
 REFERENCES ON ELECTRICAL PLANS WHICH
 REF FBC AND ARTS:. PLEASE ADJUST TO NEC.
  
 2)NOTE: PLEASE SEE FRIG IS NOW SHOWN AS
 A 2P20A FEED ON A SINGLE POLE SPACE.
  
 3)NOTE: PLEASE ANY HANDDRAWN CHANGES TO
 PLANS MUST BE DONE BY ARCH OF RECORD.
  
 4)NOTE: PLEASE SEE RISER DIAGRAM SHOWS
 PVC AND GR CONDUIT.
  
 5)NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW BEFORE ROUGH ELECTRICAL INSPECT-
 -ION IS CALLED IN.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 NOT ALL NOTES FROM FIRST REVIEW WERE
 ADDRESSED.
 SEE PROVISO ATTACHED TO PLANS.
 FEES WILL BE DUE FOR REVISION.
 IF PLANS COME BACK FOR ANY COMMENTS BY
 OTHER TRADES , PLEASE ADDRESS COMMENTS
 AT THIS TIME TO AVOID REVISIONS AT LATER
 DATE.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-04-26 Cont ID  
Sent By csiegber Date 2004-08-18 Time 12:19 Rev Time 0.75
Received By dpalmer Date 2004-04-26 Time 09:09 Sent To M
Notes
2004-04-26 00:00:00********** UNSAT ***********
  
 1)NOTE: PLEASE SEE NOTE:9 MENTIONS THAT
 ALL WIRE TO BEA MIN OF #12, YET PANELS
 SHOWS #14. PLEASE CORRELATE.
  
 2)NOTE: PLEASE SEE ALL NEC ARTS REFER-
 -ENCED ON PLANS MENTIONS PER FBC.
 THESE ARE 2002 NEC CODES.
  
 3)NOTE: PLEASE SHOW GROUNDING ELECTRODE
 SYSTEM TO BLDG/FOOTER STEEEL, COLD
 WATER. 250.50
  
 4)NOTE: PLEASE SEE OCP ON PANEL SCHEDULE
 -S FOR ALL 220V ITEMS. THESE APPEAR TO
 BE MISPRINTS AND SHOW ALL AS 1-POLE
 BRKRS.
  
 5)NOTE: PLEASE SEE PANEL SCHEDULE AND
 RISER DIAGRAM. SHOWS 3#-? FOR CONDUCTORS
 TO SUB PANEL. PLEASE VERIFY AWG AND # OF
 CONDUCTORS.
 310.16, 215.5
  
 6)NOTE: PLEASE SEE NEC 220. PLEASE SHOW
 LOAD CALCULATIONS AS SET FORTH IN 220
 FOR MIN LOADS ETC. LOAD CALCULATIONS
 NEED TO BE SHOWN. 215.5
  
 7)NOTE: PLEASE SEE NFPA-72 8-1.4.2 FOR
 SD INSTALLATION. SD SHOWN OUTSIDE BEDRM
 #3/ KITCHEN MAY NEED TO BE MOVED.
 THIS IS JUST AN FYI.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2006-06-30 Cont ID  
Sent By adarroug Date 2006-06-30 Time 16:30 Rev Time 0.00
Received By adarroug Date 2006-06-30 Time 16:30 Sent To E
Notes
2006-06-30 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2006-06-16 Cont ID  
Sent By adarroug Date 2006-06-16 Time 15:20 Rev Time 0.00
Received By adarroug Date 2006-06-16 Time 15:20 Sent To E
Notes
2006-06-16 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2006-06-08 Cont ID  
Sent By adarroug Date 2006-06-08 Time 13:31 Rev Time 0.00
Received By adarroug Date 2006-06-08 Time 13:31 Sent To E
Notes
2006-06-08 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-03-03 Cont ID  
Sent By adarroug Date 2006-03-03 Time 12:13 Rev Time 0.00
Received By adarroug Date 2006-03-03 Time 12:13 Sent To P
Notes
2006-03-03 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-01-10 Cont ID  
Sent By ptjomsto Date 2006-01-10 Time 13:15 Rev Time 0.00
Received By ptjomsto Date 2006-01-10 Time 13:14 Sent To  
Notes
2006-01-10 00:00:00REV GIVEN TO BILL TROBAUGH

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2005-12-01 Cont ID  
Sent By adarroug Date 2005-12-01 Time 16:17 Rev Time 0.00
Received By adarroug Date 2005-12-01 Time 16:17 Sent To E
Notes
2005-12-01 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-11-14 Cont ID  
Sent By adarroug Date 2005-11-14 Time 14:56 Rev Time 0.00
Received By adarroug Date 2005-11-14 Time 14:56 Sent To E
Notes
2005-11-14 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-04-29 Cont ID  
Sent By adarroug Date 2005-04-29 Time 11:14 Rev Time 0.00
Received By adarroug Date 2005-04-29 Time 11:14 Sent To P
Notes
2005-04-29 00:00:00TO "KSTEVENS" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-03-16 Cont ID  
Sent By adarroug Date 2005-03-16 Time 14:20 Rev Time 0.00
Received By adarroug Date 2005-03-16 Time 14:20 Sent To M
Notes
2005-03-16 00:00:00TO "SFR""M"

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-03-02 Cont ID  
Sent By adarroug Date 2005-03-02 Time 14:38 Rev Time 0.00
Received By adarroug Date 2005-03-02 Time 14:38 Sent To E
Notes
2005-03-02 00:00:00TO DPALMER DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-02-07 Cont ID  
Sent By adarroug Date 2005-02-07 Time 08:55 Rev Time 0.00
Received By adarroug Date 2005-02-07 Time 08:55 Sent To E
Notes
2005-02-07 00:00:00TO D.PALMER DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-08-18 Cont ID  
Sent By csiegber Date 2004-08-18 Time 12:19 Rev Time 0.00
Received By csiegber Date 2004-08-18 Time 12:18 Sent To E
Notes
2004-08-18 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-22 Cont ID  
Sent By alange Date 2004-04-22 Time 14:03 Rev Time 0.00
Received By alange Date 2004-04-22 Time 14:03 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-05 Cont ID  
Sent By mmclean Date 2004-04-21 Time 11:32 Rev Time 0.00
Received By csiegber Date 2004-04-20 Time 12:27 Sent To  
Notes
2004-04-20 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-03-23 Cont ID  
Sent By pkrauss Date 2005-03-23 Time 14:00 Rev Time 0.35
Received By pkrauss Date 2005-03-23 Time 14:00 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2005-02-17 Cont ID  
Sent By prafter Date 2005-02-17 Time 08:35 Rev Time 1.25
Received By prafter Date 2005-02-17 Time 08:35 Sent To B
Notes
2005-02-17 00:00:00THIRD MECH. REVIEW:
  
 1. RETURN AIR DUCT FROM BALLERY
 REFLECTS 16" THEN CHANGES TO 10" DUCT
 RETURNING TO A.H.U.#1 .
 PLEASE CORRECT.
 2. RETURN AIR DUCT FROM BEDROOM #3 NOT
 SIZED.
 3. RETURN AIR DUCT FROM BEDROOM #2 AND
 #3 REFLECT 10" RETURNING TO A.H.U.#1.
  
 PLEASE CORRECT R/A DUCT SIZE.
  
 4. AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIED PER 2001 FBC/M
 307.2.3 FOR A.H.U. .
  
 PAT RAFTER 561/805/6728 . PLEASE CALL
 IF THEAR ENY QUESTION.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2004-08-27 Cont ID  
Sent By pkrauss Date 2004-08-27 Time 16:38 Rev Time 0.20
Received By pkrauss Date 2004-08-27 Time 16:38 Sent To B
Notes
2004-08-27 00:00:00DENIED:2ND REQUEST
 PLEASE PROVIDE MANUAL J CALCULATIONS
 IN ACCORDANCE WITH 2001 FBC CHAPTER 13
 SUB-SECTION 607.1.ABC.1.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-04-28 Cont ID  
Sent By dpalmer Date 2004-08-23 Time 17:12 Rev Time 0.40
Received By pkrauss Date 2004-04-28 Time 09:49 Sent To P
Notes
2004-04-28 00:00:00DENIED:
 PLEASE PROVIDE THE FOLLOWING:
  
 1.ENERGY & MANUAL J CALCULATIONS PER
 2001 FBC CHAPTER 13, SUB-CHAPTER 6.
  
 2.AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED PER 2001 FBC(M)
 307.2.3.

Review Stop P PLUMBING
Rev No 6 Status P Date 2006-03-09 Cont ID  
Sent By jleech Date 2006-03-09 Time 07:22 Rev Time 0.33
Received By jleech Date 2006-03-09 Time 07:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 2005-05-14 Cont ID  
Sent By btrobaug Date 2005-12-23 Time 12:40 Rev Time 0.75
Received By jleech Date 2005-05-14 Time 10:19 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2005-04-02 Cont ID  
Sent By kstevens Date 2005-04-02 Time 11:51 Rev Time 0.75
Received By kstevens Date 2005-04-02 Time 11:51 Sent To B
Notes
2005-04-02 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT P-2 SANITARY RISER DIAGRAM DOES
 NOT MEET THE CODE REQUIREMENTS:
 A) SHOW ALL PIPE SIZES. SECTIONS
 104.2.1. AND TABLE 709.1
 B) RISER DIAGRAM INDICATES 2" PIPE TO
 WATER CLOSETS. PER TABLE 709.1 FOOTNOTE
 "D" TRAP SIZE SHALL BE CONSISTANT WITH
 FIXTURE OUTLET SIZE. MANUF.
 SPECIFICATION SHEETS WILL BE REQUIRED AT
 THE TIME OF PLUMBING FINAL SHOWING THE
 OUTLET SIZE OF WATER CLOSETS.
 C) WHITE OUT IS NOT APPROVED FOR SIGNED
 SEALED AND DATED PLANS. SECTION
 104.2.1.3.
 D) FITTING AT JUNCTION OF W/M AND
 UTILITY SINK DOES NOT COMPLY WITH
 SECTION 706.3. FITTING SHALL GUIDE
 SEWAGE IN DIRECTION OF FLOW.
 E) VENT FOR MASTER BATH WATER CLOSET
 APPEARS TO BE A DRY HORIZONTAL VENT
 WHICH IS NOT APPROVED PER SECTIONS 905.3
 AND 905.4.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 3 Status F Date 2005-03-11 Cont ID  
Sent By gsalfeld Date 2005-03-11 Time 14:38 Rev Time 1.00
Received By gsalfeld Date 2005-03-11 Time 14:38 Sent To  
Notes
2005-03-11 00:00:003/11/05 DENIED GS
  
 1-THE ISLAND SINK IN THE KITCHEN SHALL
 BE SHOWN ON THE SANITARY RISER DIAGRAM

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-02-16 Cont ID  
Sent By kstevens Date 2005-02-16 Time 10:57 Rev Time 0.60
Received By kstevens Date 2005-02-16 Time 10:56 Sent To M
Notes
2005-02-16 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT P-2 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN, DOES NOT
 MEET CODE REQUIREMENTS, NOR IS IT DRAWN
 IN A CLEAR ISOMETRIC FORM.
 A) SEE EXAMPLE ON SHT P-2 IN RED INK
 THAT SHOWS PIPING THAT IS DRAWN IN THE
 VERTICLE INDICATES PIPING TO A SECOND
 FLOOR. AND SEE EXAMPLE OF REMDEDY FOR
 THE W/M, UTILITY SINK.
 B) ISOMETRIC IS A REVERSE OF THE FLOOR
 PLAN. SECTION 104.2.1.
 C) BATH #3 IS MISSING THE TUB ON THE
 SANT. RISER THAT IS SHOWN ON THE FLOOR
 PLAN. SECTION 104.2.1.
 D) UTILITY SINK IS NOT VENTED. SECTION
 901.2.1.
 E) WASH MACHINE REQUIRES A MIN. 2'
 STANDPIPE, AND A CLEANOUT 4' ABOVE THE
 FLOOR. SECTIONS 1002.1 & 708.10.
 F) TRAPS ARE REQUIRED ON ALL SHOWERS,
 TUBS, AND BIDET. SECTION 1002.1.
 G) THE AIR ADMITTENCE VALVE FOR THE
 ISLAND SINK IN THE KITCHEN SHALL BE
 SHOWN ON THE SANITARY RISER DIAGRA.
 SECTION 104.2.1. & SECTION 901.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-05-03 Cont ID  
Sent By pkrauss Date 2004-04-28 Time 10:02 Rev Time 0.33
Received By jleech Date 2004-05-03 Time 20:04 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-04-21 Cont ID  
Sent By csiegber Date 2004-04-20 Time 12:22 Rev Time 0.00
Received By mmclean Date 2004-04-21 Time 11:32 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy