Plan Review Details - Permit 04040882
Plan Review Stops For Permit 04040882
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-09-22 Cont ID  
Sent By jgomez Date 2004-09-22 Time 07:44 Rev Time 0.33
Received By jgomez Date 2004-09-22 Time 07:44 Sent To PC
Notes
2004-09-22 00:00:00CHECKLIST:
 1-SURVEY SHOWS FLOOD ZONE AO AND B
 SIMULTANEOUSLY. REVISE AS REQUIRED TO
 SHOW FLOOD ZONE B AS PER LOMR.
  
 **GARAGE DOOR PRODUCT APPROVAL IS OK.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-06-30 Cont ID  
Sent By csiegber Date 2004-08-30 Time 10:01 Rev Time 0.33
Received By jgomez Date 2004-06-30 Time 13:37 Sent To PC
Notes
2004-06-30 00:00:00CHECKLIST:
 1-SURVEY WITH FLOOD ZONE REVISION SHOWS
 FIRM ZONE AO AND B SIMULTANEOUSLY.
 NEED TO REVISE SURVEY SHOWING ONLY
 ONE FLOOD ZONE.
 2-PROVIDE COPIES OF GARAGE DOOR DRAWINGS
 SUBMITTED TO SBCCI FOR APPROVAL. NEED
 DRAWINGS SIGNED AND SEALED ON DATED AS
 NOTED ON SBCCI EVALUATION REPORT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-05-06 Cont ID  
Sent By csiegber Date 2004-06-22 Time 14:18 Rev Time 1.00
Received By jgomez Date 2004-05-06 Time 09:11 Sent To PC
Notes
2004-05-06 00:00:00BUILDING REVIEW PROVISO:
 1-FLOOD ZONE AO: NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-04-16 Cont ID  
Sent By dpalmer Date 2004-04-16 Time 12:47 Rev Time 0.25
Received By dpalmer Date 2004-04-16 Time 12:47 Sent To M
Notes
2004-04-16 00:00:00** REDLINED
  
 SD'S TO BE INSTALLED PER NFPA-72 8-1.4.2

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-08-30 Cont ID  
Sent By csiegber Date 2004-08-30 Time 10:01 Rev Time 0.00
Received By csiegber Date 2004-08-30 Time 10:01 Sent To B
Notes
2004-08-30 00:00:00TO JG DESK/SUMBITTALS/NEW PA'S

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-22 Cont ID  
Sent By csiegber Date 2004-06-22 Time 14:18 Rev Time 0.00
Received By csiegber Date 2004-06-22 Time 14:18 Sent To B
Notes
2004-06-22 00:00:00TO JG DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-05-06 Cont ID  
Sent By mmclean Date 2004-04-15 Time 09:36 Rev Time 0.00
Received By jgomez Date 2004-04-13 Time 12:40 Sent To PC
Notes
2004-04-15 00:00:00TO SFD RACK/E
2004-04-13 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-04-26 Cont ID  
Sent By dpalmer Date 2004-04-16 Time 12:47 Rev Time 0.30
Received By pkrauss Date 2004-04-26 Time 08:52 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-04-26 Cont ID  
Sent By pkrauss Date 2004-04-26 Time 08:52 Rev Time 0.25
Received By jleech Date 2004-04-26 Time 17:02 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-04-15 Cont ID  
Sent By mmclean Date 2004-04-15 Time 09:36 Rev Time 0.00
Received By mmclean Date 2004-04-15 Time 09:36 Sent To I
Notes
***NONE***