Plan Review Stops For Permit 04040818 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-10-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-10-13 |
Time |
09:34 |
Rev Time |
1.11 |
Received By |
jwitmer |
Date |
2004-09-15 |
Time |
15:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-05-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-09-01 |
Time |
13:12 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2004-05-25 |
Time |
09:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-04-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-04-28 |
Time |
16:47 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2004-04-28 |
Time |
16:47 |
Sent To |
|
|
Notes |
2004-04-28 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 04040818 | | ADD: 5601 CORPORATE WAY# 108 | | CONT: K& M COMMERCIAL | | TEL: (561)358-3331 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | ITIONS, EXIT ENCLOSURES, AND FIRE | | RATED WALLS REQUIRED TO HAVE PROTECTED | | OPENINGS SHALL BE EFFECTIVELY AND | | PERMANETLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | CEILING CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | PROTECT ALL OPENINGS". | | | | 3) TABLE 803.3 MINIMUM INTERIOR FINISH | | CLASSIFICATION; PROVIDE INFORMATION | | BASED ON INTERIOR FINISH REQUIREMENTS | | BASED ON OCCUPANCY | | | | 4) NOTE # 4 WALL FINISHES: | | 104.2.1 W.P.B. ADMINISTRATIVE CODE | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | INFORMATION, IN THE FORM OF NOTES OR | | OTHERWISE, AS TO THE QUALITY OF | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | CONFORMITY WITH THE TECHNICAL CODES. | | SUCH INFORMATION SHALL BE SPECIFIC | | AND THE TECHNICAL CODES "SHALL NOT BE | | CITED AS A WHOLE OR IN PART, NOR THE | | TERM "LEGAL" OR ITS RQUIVALENT BE USED | | AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION". | | | | 5) SINKS 11-4.24.2 SINKS SHALL BE MOUNT- | | ED WITH THE COUNTER OR RIM NO HIGHER | | THAN 34". | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-11-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-11-02 |
Time |
15:18 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-11-02 |
Time |
15:18 |
Sent To |
|
|
Notes |
2004-11-02 00:00:00 | REV'S OK. | | REVISED LOAD CALCS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2004-09-21 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-27 |
Time |
10:33 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-09-21 |
Time |
15:42 |
Sent To |
|
|
Notes |
2004-09-21 00:00:00 | ***** UNSAT ***** | | | | 1)NOTE: PLEASE CLARIFY LOAD CALCULATIONS | | AS THEY SEEM BE FIGURED AT 208V. | | PLEASE SEE RISER INDICATES PANEL AS | | 3-PHASE>? IF 3-PHASE, PLEASE FIGURE | | LOAD CALCS ACCORD. | | NEC 220 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-05-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-08 |
Time |
17:28 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-05-08 |
Time |
17:28 |
Sent To |
|
|
Notes |
2004-05-08 00:00:00 | ******** PROVISO/ REVISION NEEDED ***** | | | | 1)NOTE: PLEASE SUBMIT AND SHOW ALL NEW | | CIRCUITING ON PLANS AND CORRELATE WITH | | A PANEL SCHEDULE TO BE SUBMITTED BEFORE | | FINAL INSPECTION. | | MUST BE REVIEWED, STAMPED AND RETURNED | | TO JOBSITE FOR FINAL INSPECTION. | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-04-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-04-19 |
Time |
05:25 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-04-19 |
Time |
05:25 |
Sent To |
|
|
Notes |
2004-04-19 00:00:00 | ********* UNSAT *********** | | | | 1)NOTE: PLEASE SEE 2002 NEC 700.12E FOR | | CIRCUITING OF EM LTS. | | PLEASE SEE NOTE #6 MENTIONS TO WIRE | | AHEAD OF DISC. LOCAL BRANCH CIRCUITING | | IS REQ'D AHEAD OF ANY LOCAL DEVICE | | SWITCHING. | | | | 2)NOTE; PLEASE BE SURE RAISED SEALED | | CAN BE CLEARLY VISABLE ON ALL SHEETS. | | SOME ARE VERY FAINT. | | FS 481.221. | | | | 3)NOTE: MIN CIRCUITING WILL BE REQ'D ON | | PLANS ALONG WITH A PANEL SCHEDULE BEFORE | | FINAL. THIS MAY BE DONE AT THIS TIME TO | | AVOID REVISION FEES AT A LATER DATE. | | | | PLEASE SEE FIRE REVIEW COMMENTS THAT | | WILL AFFECT ELECTRICAL PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
|
Date |
2004-10-01 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-10-01 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-10-01 |
Time |
14:19 |
Sent To |
|
|
Notes |
2004-10-01 00:00:00 | 1) DEMOLITION, RENOVATION AND | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-05-05 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-05-05 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-05-05 |
Time |
11:14 |
Sent To |
|
|
Notes |
2004-05-05 00:00:00 | 1) ANOTHER EXIT SIGN IS NEEDED TO | | DIRECT PERSONS INTO OFFICE # 3. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2004-04-13 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-04-13 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-04-13 |
Time |
12:47 |
Sent To |
|
|
Notes |
2004-04-13 00:00:00 | 1) DEMOLITION, RENOVATION, AND | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | 2) ELECTRICAL PAGE ONLY SHOWS ONE EXIT | | DIRECTION BACK THROUGH RECEPTION AREA. | | IF THAT IS THE PROPOSED CONDITION, | | A DEAD-END CONDITION EXISTS GREATER | | THAN THE CODES ALLOW. ANOTHER EXIT | | SIGN DIRECTING PERSONS INTO OFFICE | | # 3 IS REQUIRED AND THE INTERIOR DOOR | | FOR OFFICE # 3 CANNOT BE SUBJECT TO | | LOCKING. PLEASE REVISE PLANS AS | | NECESSARY. | | | | 3) DEMOLITION DEBRIS SHALL BE REMOVED | | FROM THE SITE DAILY. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-10-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-27 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-27 |
Time |
10:33 |
Sent To |
E |
|
Notes |
2004-10-27 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-09-01 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-09-01 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-09-01 |
Time |
13:12 |
Sent To |
B |
|
Notes |
2004-09-01 00:00:00 | TO COMM BD#24 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-05-04 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-04 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-04 |
Time |
15:10 |
Sent To |
|
|
Notes |
2004-05-04 00:00:00 | TO COMM BD#11 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-04-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-04 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-13 |
Time |
10:37 |
Sent To |
|
|
Notes |
2004-04-13 00:00:00 | TO COMM BD#20 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2004-04-27 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-04-27 |
Time |
08:41 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2004-04-27 |
Time |
08:41 |
Sent To |
|
|
Notes |
2004-04-27 00:00:00 | NO MECHANICAL PLANS OR CONTRACTOR | | INDICATED WITH PERMIT APPLICATION. | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | WITH MECHANICAL PERMIT APPLICATION. | | 1.PLANS - DUCT/GRILLE SIZE MATERIAL & | | LAYOUT. | | | | 2.OUTSIDE AIR CALCULATIONS PER 2001 | | FBC(M) TABLE 403.3. | | | | 3.PROVIDE EQUIPMENT SCHEDULE. | | | | 4.INDICATE CONDENSATE LINE SIZE, | | MATERIAL AND TERMINATION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2004-10-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-10-09 |
Time |
07:44 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-10-09 |
Time |
07:44 |
Sent To |
|
|
Notes |
2004-10-09 00:00:00 | REVISION OK - CHANGED LOCATION FOR W/C | | AND LAV |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-05-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-05-22 |
Time |
05:51 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-05-22 |
Time |
05:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-04-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-04-26 |
Time |
18:48 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-04-26 |
Time |
18:32 |
Sent To |
|
|
Notes |
2004-04-26 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES. | | | | 1) SHT 2 AIR CHAMBERS NOT APPROVED. SEE | | SECTION 604.9 WATER HAMMER ARRESTORS | | WHERE REQUIRED, PDI-WH 201 AND MANUF. | | INSTALLATION INSTRUCTIONS FOR LOCATION. | | NOT IN CEILING. | | 2) NOT ALL SIGNATURES ARE THE SAME ON | | THE SEAL. NOT ALL SEALS READABLE. | | NOT ALL SHEETS SIGNED AND SEALED. | | TITLE BLOCK REQUIRES A SPACE FOR ARCHIT- | | ECTS PRINTED NAME.FAC-61G1-16.002 -003 | | -004. FS481.2055 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|