Plan Review Details - Permit 04040629
Plan Review Stops For Permit 04040629
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-05-11 Cont ID  
Sent By pschmitz Date 2004-05-11 Time 14:58 Rev Time 0.75
Received By lsmith Date 2004-05-11 Time 15:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-05-20 Cont ID  
Sent By dpalmer Date 2004-05-20 Time 15:13 Rev Time 0.33
Received By dpalmer Date 2004-05-20 Time 15:13 Sent To  
Notes
2004-05-20 00:00:00ATTACHED NEW SHEETS.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-05-17 Cont ID  
Sent By dpalmer Date 2004-05-17 Time 11:05 Rev Time 0.33
Received By dpalmer Date 2004-05-17 Time 11:04 Sent To  
Notes
2004-05-17 00:00:00************ UNSAT ***************
  
 1)NOTE: PLEASE SEE NOTES FROM THE FIRST
 TWO REVIEWS. WIRING DIAGRAM IS STILL
 NOT COMPLETE. SAME PLANS WERE SUBMITTED
 BACK FOR REVIEW WITH NO CORRECTIONS
 MADE. WIRING DIAGRAM IS MISSING WIRE
 SIZES, CONDUIT SIZES ETC.
  
 PLEASE ALSO SEE HAND MADE CHANGES TO
 SIGNED AND SEALED PLANS MAY ONLY BE
 DONE BY THE ENGINEER OF RECORD.
  
 PLEASE ALSO SEE BZ RECEIPT ATTACHED.
 SHOULD HAVE PAID 10% RESUB.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-05-05 Cont ID  
Sent By csiegber Date 2004-05-14 Time 11:41 Rev Time 0.25
Received By dpalmer Date 2004-05-05 Time 06:25 Sent To P
Notes
2004-05-05 00:00:00**********UNSAT ************
  
 1)NOTE: PLEASE CORRELATE WIRING DIAGRAM
 WITH EQUIPMENT BEING INSTALLED SPECIFIC
 TO THIS POOL/ PERMIT .
 WING DIAGRAM IS NOT COMPLETE AND ONLY
 MENTIONS SOME EQUIPMENT WHEN APPLICABLE.
  
 THIS THE SECOND REVIEW WITH SAME COMMENT
 FROM FIRST REVIEW. PLEASE SEE COPY OF
 FS 553.80(B)(2) GIVEN.
 PLEASE ADDRESS COMMENT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-04-17 Cont ID  
Sent By csiegber Date 2004-04-30 Time 11:31 Rev Time 0.33
Received By dpalmer Date 2004-04-17 Time 16:51 Sent To P
Notes
2004-04-17 00:00:00*********** UNSAT ***************
  
 1)NOTE: PLANS REQ'D TO BE ORIG SIGNED,
 DATED AND SEALED PER FS 471.025, FAC 61G
 15-23.002
  
 2)NOTE: PLEASE CORRELATE PLANS/WIRING
 DIAGRAM WITH ALL EQUIPMENT BEING INSTALL
 -ED. HEAT PUMP ETC.
  
 3)NOTE: PLEASE SUBMIT SPECS FOR HEAT
 PUMP. PLEASE BE SURE LISTING IS INDICAT-
 -ED.
  
 4)NOTE: PLEASE SUBMIT LOAD CALCULATIONS
 FOR EXSITING SERVICE AND INCLUDE ALL
 NEW LOADS BEING ADDED. SIZE OF EXIST
 SERVICE.
  
 5)NOTE: PLEASE INCLUDE ALL LICENSE #'S
 ON TITLE BLOCK AS REQ'D UNDER FAC 61G15-
 -23.002
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-05-14 Cont ID  
Sent By csiegber Date 2004-05-14 Time 11:41 Rev Time 0.00
Received By csiegber Date 2004-05-14 Time 11:41 Sent To E
Notes
2004-05-14 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-30 Cont ID  
Sent By csiegber Date 2004-04-30 Time 11:31 Rev Time 0.00
Received By csiegber Date 2004-04-30 Time 11:31 Sent To E
Notes
2004-04-30 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-15 Cont ID  
Sent By csiegber Date 2004-04-15 Time 09:50 Rev Time 0.00
Received By csiegber Date 2004-04-15 Time 09:50 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-08 Cont ID  
Sent By mmclean Date 2004-04-14 Time 12:47 Rev Time 0.00
Received By csiegber Date 2004-04-08 Time 14:20 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-05-11 Cont ID  
Sent By csiegber Date 2004-05-14 Time 11:41 Rev Time 1.25
Received By pschmitz Date   Time   Sent To B
Notes
2004-05-11 00:00:00PROVISO:
 BACL FLOW REVENTERR PRIOR TO COMMENCING
 WORK.

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-04-19 Cont ID  
Sent By dpalmer Date 2004-05-05 Time 06:25 Rev Time 0.50
Received By kstevens Date 2004-04-19 Time 17:46 Sent To B
Notes
2004-04-19 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 2) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 3) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 4) PROFESSIONAL ENGINEER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS,
 SPECIFICATIONS, REPORTS AND FINAL BID
 DOCUMENTS PROVIDED TO THE OWNER OR THE
 OWNER'S REPRESENTATIVE, OR OTHER DOCU-
 MENTS PREPARED OR ISSUED BY SAID REGIS-
 TRANT AND BEING FILED FOR PUBLIC RECORD.
 THE DATE THAT THE SIGNATURE AND SEAL IS
 AFFIXED AS PROVIDED HEREIN SHALL BE EN-
 TERED ON SAID PLANS, SPECIFICATIONS, RE-
 PORTS, OR OTHER DOCUMENTS IMMEDIATELY
 UNDER THE SIGNATURE OF THE PROFESSIONAL
 ENGINEER, FAC 61G15-23.002(1)
 FS 471.025
 EACH SHEET OF PLANS AND PRINTS WHICH
 MUST BE SEALED UNDER THE PROVISIONS OF
 CHAPTER 471 SHALL BE SEALED, SIGNED AND
 DATED BY THE PROFESSIONAL ENGINEER IN
 RESPONSIBLE CHARGE. FAC 61G15-23.002(2)
 FS 471.025 - SIGNATURE IS A COPY AND THE
 SEAL IS REQUIRED ON BOTH SETS OF PLANS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-08 Time 14:20 Rev Time 0.00
Received By mmclean Date 2004-04-14 Time 12:47 Sent To I
Notes
***NONE***