Plan Review Details - Permit 04031169
Plan Review Stops For Permit 04031169
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-05-10 Cont ID  
Sent By pschmitz Date 2004-05-08 Time 07:47 Rev Time 0.50
Received By lsmith Date 2004-05-10 Time 10:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-04-01 Cont ID  
Sent By kstevens Date 2004-03-31 Time 17:33 Rev Time 0.50
Received By lsmith Date 2004-04-01 Time 08:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-04-23 Cont ID  
Sent By dpalmer Date 2004-04-23 Time 17:16 Rev Time 0.33
Received By dpalmer Date 2004-04-23 Time 17:16 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-03-30 Cont ID  
Sent By lmartine Date 2004-04-23 Time 12:13 Rev Time 0.25
Received By btrobaug Date 2004-03-30 Time 06:56 Sent To P
Notes
2004-03-30 00:00:00 
 PLEASE NOTE THAT THE SIGNATURE OF THE EN
 GINEER IS REQUIRED ON HIS/HER SEAL PER
 61G15-23.002 FLORIDA ADMINISTRATIVE CODE
 INITIALS ARE NOT ACCEPTABLE PER F.B.P.E.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-22 Cont ID  
Sent By alange Date 2004-04-22 Time 10:46 Rev Time 0.00
Received By alange Date 2004-04-22 Time 10:46 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-30 Cont ID  
Sent By alange Date 2004-03-30 Time 11:15 Rev Time 0.00
Received By alange Date 2004-03-30 Time 11:15 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-29 Cont ID  
Sent By lsmith Date 2004-03-29 Time 13:55 Rev Time 0.00
Received By lsmith Date 2004-03-29 Time 13:55 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-23 Cont ID  
Sent By mmclean Date 2004-03-26 Time 11:39 Rev Time 0.00
Received By csiegber Date 2004-03-23 Time 08:55 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-05-08 Cont ID  
Sent By pschmitz Date 2004-05-08 Time 07:44 Rev Time 1.00
Received By pschmitz Date   Time   Sent To B
Notes
2004-05-08 00:00:00PROVISO:
 BACK FLOW PREVENTER PRIOR TO COMMENCING
 WORK.

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-03-31 Cont ID  
Sent By dpalmer Date 2004-04-23 Time 17:16 Rev Time 0.50
Received By kstevens Date 2004-03-31 Time 17:33 Sent To B
Notes
2004-03-31 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 2) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 3) FBC-2001424.2.7.1 POOL CIRCULATING
 PUMPS SHALL BE EQUIPPED ON THE INLET
 SIDE WITH AN APPROVED TYPE HAIR AND LINT
 STRAINER WHEN USED WITH A PRESSURE FIL-
 TER. (DETAIL OR ADD TO NOTES)
 4) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 5) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 6) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 7) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 8)A PROFESSIONAL ENGINEER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS,
 SPECIFICATIONS, REPORTS AND FINAL BID
 DOCUMENTS PROVIDED TO THE OWNER OR THE
 OWNER'S REPRESENTATIVE, OR OTHER DOCU-
 MENTS PREPARED OR ISSUED BY SAID REGIS-
 TRANT AND BEING FILED FOR PUBLIC RECORD.
 THE DATE THAT THE SIGNATURE AND SEAL IS
 AFFIXED AS PROVIDED HEREIN SHALL BE EN-
 TERED ON SAID PLANS, SPECIFICATIONS, RE-
 PORTS, OR OTHER DOCUMENTS IMMEDIATELY
 UNDER THE SIGNATURE OF THE PROFESSIONAL
 ENGINEER, FAC 61G15-23.002(1)
 FS 471.025
 EACH SHEET OF PLANS AND PRINTS WHICH
 MUST BE SEALED UNDER THE PROVISIONS OF
 CHAPTER 471 SHALL BE SEALED, SIGNED AND
 DATED BY THE PROFESSIONAL ENGINEER IN
 RESPONSIBLE CHARGE. FAC 61G15-23.002(2)
 FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2004-04-23 Cont ID  
Sent By sgraham Date 2004-04-22 Time 12:16 Rev Time 0.25
Received By lmartine Date   Time   Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-03-26 Cont ID  
Sent By alange Date 2004-04-22 Time 10:46 Rev Time 0.00
Received By mmclean Date 2004-03-26 Time 11:39 Sent To I
Notes
2004-03-26 00:00:00DENIED, NEED TO SHOW WORK ON SURVEY WITH
 SETBACKS.CALLED OWNER WILL PROVIDE
 CORRECTED COPY MM