Plan Review Details - Permit 04031163
Plan Review Stops For Permit 04031163
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-07-28 Cont ID  
Sent By csiegber Date 2004-08-04 Time 10:41 Rev Time 1.00
Received By alange Date 2004-07-28 Time 13:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-09 Cont ID  
Sent By jleech Date 2004-07-27 Time 19:54 Rev Time 2.00
Received By alange Date 2004-04-09 Time 09:00 Sent To  
Notes
2004-04-09 00:00:00DENIED
 1.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 3.SUBMIT AN ELEVATION CERTIFICATE.
 STRUCTURE IS IN A FLOOD ZONE.
  
 4.BUILDING VALUATION OF $15,000
 TOO LOW.VALUE HAS BEEN RECALCULATED
 BASED UPON SBCCI BUILDING VALUATION
 DATA TO $68,802.ADITIONAL PERMIT FEES
 ARE DUE.
  
 5.CITY OF WEST PALM BEACH CODE
 SEC. 94-546 (B) (1) PROVISIONS FOR
 FLOOD HAZARD REDUCTION.
 RESIDENTIOAL CONSTRUCTION. ALL NEW
 CONSTRUCTION OR SUBSTANTIAL IMPROVEMENT
 OF ANY EXISTING RESIDENTIAL STRUCTURE
 SHALL HAVE THE LOWEST FLOOR, INCLUDING
 BASEMENT, ELEVATED TO SIX INCHES ABOVE
 THE BASE FLOOD ELEVATION. SEE ATTACHED
 PAGES.
  
 6. WINDOW BUCKS SHALL COMPLY WITH
 FBC 1707.4.4.2 BUCKS SHALL EXTEND BEYOND
 THE INTERIOR FACE OF THE WINDOW FRAME
 SUCH THAT FULL SUPPORT OF THE FRAME IS
 PROVIDED.HAVE BUCK DETAIL REFLECT THIS
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By btrobaug Date 2006-04-20 Time 07:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-03-27 Cont ID  
Sent By btrobaug Date 2006-03-27 Time 07:42 Rev Time 0.33
Received By btrobaug Date 2006-03-27 Time 07:39 Sent To PC
Notes
2006-03-27 00:00:00 
  
 ALL CHANGES TO THE PLAN MUST BE MADE BY
 THE DESIGNER OF RECORD. HAVE PLANS
 REDRAWN AND RESEALED BY THE ARCHITECT
 AND RESUBMIT
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-07-21 Cont ID  
Sent By btrobaug Date 2004-07-21 Time 11:04 Rev Time 0.50
Received By btrobaug Date 2004-07-21 Time 10:30 Sent To P
Notes
2004-07-21 00:00:00 
 PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 THE DEN LISTS "EXISTING ELECTRICAL TO
 REMAIN". THERE IS WORK IN THIS ROOM, SEE
 SHEET A-1, THIS ROOM MUST COMPLY WITH
 210.52.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-06-14 Cont ID  
Sent By csiegber Date 2004-07-19 Time 12:44 Rev Time 1.00
Received By btrobaug Date 2004-04-02 Time 11:55 Sent To M
Notes
2004-04-02 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE PANEL SCHEDULE NOTES INDICATE A
 200 AMP SERVICE. THE RISER IS LABLED
 150 AMP. PLEASE CORRELATE.
  
 2} PER 220.31 THERE IS NO DEMAND TAKEN
 FOR THE A/C. ALSO NOTE THAT THIS LOAD
 CALCULATION ALLOWS ALL BUT THE 1ST
 8000VA TO BE TAKEN @ 40%. RECALCULATE
 LOAD AND INDICATE METHOD USED. (ARTICLE
 #.)
  
 3} THE LOADS FOR THE HEAT STRIP & COND.
 UNIT ARE REVERSED ON THE SCHEDULE.
  
 4} RECEPTACLES NEED TO BE ADDED IN THE
 BEDROOM TO COMPLY WITH 210.52(A).
  
 5} PLEASE PROVIDE A PANEL SCHEDULE SO
 THAT BRANCH CIRCUIT CODE COMPLIANCE CAN
 BE DETERMINED.
  
 6} PLEASE LIST ALL THE REQ'D
 DEDICATED BATH(S) CIRCUIT(S) ON PANEL
 SCHEDULE. PER 210.52D, 210.11C3
  
 7} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
  
 8} ISLAND RECEPTACLES MUST BE GFI
 PER210.8(A)(6).
  
 9} A RECEPTACLE MUST BE ADDED AT THE
 BACK OF THE HOUSE (OUTSIDE PER
 210.52(E).
  
 10} SEE PLUMBING COMMENTS FOR TITLE
 BLOCK & SEAL REQUIREMENTS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL,
 ALSO NOTE CODE REDLINED SET OF PLANS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-06-12 Cont ID  
Sent By adarroug Date 2006-06-12 Time 08:42 Rev Time 0.00
Received By adarroug Date 2006-06-12 Time 08:42 Sent To M
Notes
2006-06-12 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-05-23 Cont ID  
Sent By adarroug Date 2006-05-23 Time 11:39 Rev Time 0.00
Received By adarroug Date 2006-05-23 Time 11:39 Sent To M
Notes
2006-05-23 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-04-15 Cont ID  
Sent By adarroug Date 2006-04-15 Time 14:24 Rev Time 0.00
Received By adarroug Date 2006-04-15 Time 14:24 Sent To E
Notes
2006-04-15 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-03-17 Cont ID  
Sent By adarroug Date 2006-03-17 Time 16:51 Rev Time 0.00
Received By adarroug Date 2006-03-17 Time 16:51 Sent To E
Notes
2006-03-17 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-08-04 Cont ID  
Sent By csiegber Date 2004-08-04 Time 10:41 Rev Time 0.00
Received By csiegber Date 2004-08-04 Time 10:41 Sent To B
Notes
2004-08-04 00:00:00TO AL DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-08-02 Cont ID  
Sent By mmclean Date 2004-08-03 Time 16:17 Rev Time 0.00
Received By csiegber Date 2004-08-02 Time 14:10 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-07-19 Cont ID  
Sent By csiegber Date 2004-07-19 Time 12:44 Rev Time 0.00
Received By csiegber Date 2004-07-19 Time 12:44 Sent To E
Notes
2004-07-19 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-12 Cont ID  
Sent By mmclean Date 2004-07-19 Time 11:16 Rev Time 0.00
Received By csiegber Date 2004-07-12 Time 14:12 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-26 Cont ID  
Sent By csiegber Date 2004-03-26 Time 16:44 Rev Time 0.00
Received By csiegber Date 2004-03-26 Time 16:44 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-23 Cont ID  
Sent By mmclean Date 2004-03-26 Time 16:06 Rev Time 0.00
Received By csiegber Date 2004-03-23 Time 08:47 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-06-19 Cont ID  
Sent By tgordon Date 2006-06-19 Time 14:55 Rev Time 0.25
Received By tgordon Date 2006-06-19 Time 14:55 Sent To  
Notes
2006-06-19 00:00:00REVISION TO MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-05-25 Cont ID  
Sent By tgordon Date 2006-05-25 Time 10:31 Rev Time 0.45
Received By tgordon Date 2006-05-25 Time 10:31 Sent To  
Notes
2006-05-25 00:00:00MECHANICAL REVISION
 *** DENIED ***
 1) TWO A/C SYSTEMS ARE LISTED ON PLANS
 ONLY ONE IS TO BE INSTALLED, PLEASE
 CORRECT.
  
 2) PLEASE SHOW SUPPLY AIR DUCT SIZES TO
 MIXING BOX, CLOSET, AND BATHROOM.
  
 3) PLEASE EXPLAIN WHAT APPLIANCE THE 6"
 VTO IS FOR.
  
 4) PLEASE SHOW JOB ADDRESS ON MECHANICAL
 PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-04-05 Cont ID  
Sent By btrobaug Date 2004-06-14 Time 14:40 Rev Time 0.30
Received By pkrauss Date 2004-04-05 Time 15:22 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-07-27 Cont ID  
Sent By jleech Date 2004-07-27 Time 19:54 Rev Time 0.33
Received By jleech Date 2004-07-27 Time 19:54 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-03-31 Cont ID  
Sent By btrobaug Date 2004-07-21 Time 11:04 Rev Time 0.33
Received By kstevens Date 2004-03-31 Time 15:05 Sent To E
Notes
2004-03-31 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SHT A-2 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS.
 A) MINIMUM 3" TO WATER CLOSET. TABLE
 710.1(1) FOOTNOTE A.
 B) CLEAN OUT REQUIRED 4' ABOVE FLOOR AT
 WASHMACHINE. SECTION 708.9
 C) STANDPIPE REQUIRED AT WASH MACHINE
 SECTIONS 1002.1 & 802.4.
 D) WASH MACHINE SHALL CONNECT BELOW
 WASTE ARM OF THE KITCHEN SINK. SECTION
 706.3
 2)ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2004-08-03 Cont ID  
Sent By mmclean Date 2004-08-03 Time 16:16 Rev Time 0.00
Received By mmclean Date 2004-08-03 Time 16:16 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2004-07-19 Cont ID  
Sent By csiegber Date 2004-08-02 Time 14:10 Rev Time 0.00
Received By mmclean Date 2004-07-19 Time 11:16 Sent To I
Notes
2004-07-19 00:00:00DENIED, NEED TO HAVE 6FT SEPARATION FROM
 ADDITION AND SHED.CALLED & LEFT MSG

Review Stop Z ZONING
Rev No 1 Status F Date 2004-03-26 Cont ID  
Sent By csiegber Date 2004-07-12 Time 14:12 Rev Time 0.00
Received By mmclean Date 2004-03-26 Time 16:06 Sent To I
Notes
2004-03-26 00:00:00DENIED, SITE PLAN NOT TO SCALE.NEED TO
 PROVIDE A SITE PLAN TO SCALE WITH SET
 BACKS OR TWO COPY OF SURVEY SHOWING
 THE ADDITION WITH SETBACKS CALLED OWNER