Plan Review Details - Permit 04030820
Plan Review Stops For Permit 04030820
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-08-18 Cont ID  
Sent By jgomez Date 2004-08-18 Time 09:57 Rev Time 0.33
Received By jgomez Date 2004-08-18 Time 09:57 Sent To PC
Notes
2004-08-18 00:00:00GARAGE DOOR AND ENTRY DOOR PRODUCT
 APPROVAL. FLOOD ZONE REVISION AND
 ENGINEER LETTER TO RESPOND TO PROVISO.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-04-09 Cont ID  
Sent By csiegber Date 2004-08-17 Time 12:42 Rev Time 1.00
Received By jgomez Date 2004-04-09 Time 14:03 Sent To PC
Notes
2004-04-09 00:00:00BUILDING REVIEW PROVISO:
 1-FLOOD ZONE AO: WILL NEED TO PROVIDE
 THE ELEVATION CERTIFICATE.
 2-DETAIL E/4 AND RESIDENTIAL NOTES ON
 DRAWING #2 DON'T MATCH. CLARIFY THE
 FASTENER SPACING. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 3-TYPICAL WALL SECTION A/4: SPECIFY
 WHERE ARE TABLES 6 AND 8 FOR ROOF
 FASTENERS TAKEN FROM. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-06 Cont ID  
Sent By jleech Date 2004-03-31 Time 20:14 Rev Time 2.00
Received By jgomez Date 2004-04-05 Time 16:39 Sent To  
Notes
2004-04-05 00:00:00BUILDING REVIEW CHECKLIST:
 1-REVISE ENERGY CALCULATIONS: NEED TO BE
 CALCULATED FOR WORST CASE SCENARIO IF
 IT'S TO BE USED AS TYPICAL FOR ALL
 HOUSES. OR PROVIDE ENERGY CALCULATIONS
 THAT ARE CALCULATED FOR EACH HOUSE
 ACCORDING TO THE ORIENTATION.
 2-PROVIDE FLORIDA PRODUCT APPROVAL AND
 DRAWINGS FOR ENTRY DOOR THAT MATCH TO
 EACH OTHER. EVERYTHING TO BE BENCHMARK
 OR THERMA TRU.
 3-PROVIDE FLORIDA PRODUCT APPROVAL COVER
 FOR SLIDING GLASS DOORS AND FIXED
 WINDOWS. AND PROVIDE ONLY THE DWGS FOR
 WINDOWS/DOORS TO BE INSTALLED IN THIS
 HOUSE.
 4-DETAIL E/4 AND RESIDENTIAL NOTES ON
 DWG #2 DON'T MATCH. CLARIFY SPACING
 OF FASTENERS.
 5-TYPICAL WALL SECTION A/4. SPECIFY
 WHERE ARE TABLES 6 AND 8 FOR ROOF TILE
 FASTENING TAKEN FROM/ SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 6-IMPACT FEES PAID RECEIPT NEED TO HAVE
 A PR NUMBER. CLARIFY WHY AMOUNT PAID
 IS LESS THAN AMOUNT STAMPED ON PLANS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-03-29 Cont ID  
Sent By hmoser Date 2004-03-24 Time 16:49 Rev Time 0.45
Received By jleahy Date 2004-03-29 Time 14:55 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-08-17 Cont ID  
Sent By csiegber Date 2004-08-17 Time 12:42 Rev Time 0.00
Received By csiegber Date 2004-08-17 Time 12:42 Sent To B
Notes
2004-08-17 00:00:00TO JG DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-29 Time 15:03 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 15:03 Sent To B
Notes
2004-07-29 00:00:00TO JG DESK/NEW PROVISO

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-05-21 Cont ID  
Sent By csiegber Date 2004-05-21 Time 09:20 Rev Time 0.00
Received By csiegber Date 2004-05-21 Time 09:20 Sent To Z
Notes
2004-05-21 00:00:00REVISION

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-05 Cont ID  
Sent By mmclean Date 2004-03-18 Time 12:20 Rev Time 0.00
Received By csiegber Date 2004-03-12 Time 14:15 Sent To PC
Notes
2004-03-19 00:00:00TO SFD RACK/E
2004-03-16 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-03-24 Cont ID  
Sent By jleahy Date 2004-03-29 Time 14:56 Rev Time 0.50
Received By hmoser Date 2004-03-23 Time 18:52 Sent To E
Notes
2004-03-23 00:00:00PASS PRIVISO
 1) REFER TO SECTION 307.2.3 AUXILIARY
 DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE
 INSTALLED UNDER ALL COILS ON WITCH
 CONDENSATION WILL OCCUR.
 2) RETURN AIR REQUIREMENTS TO COMPLY
 WITH THE FLORIDA BUILDING CODE (M) 2003
 CHANGES.CHANGES WENT INTO EFFECT JULY 1
 2003
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-03-31 Cont ID  
Sent By jgomez Date 2004-04-06 Time 15:00 Rev Time 0.25
Received By jleech Date 2004-03-31 Time 20:14 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-18 Cont ID  
Sent By csiegber Date 2004-05-21 Time 09:20 Rev Time 0.00
Received By mmclean Date 2004-03-18 Time 12:20 Sent To I
Notes
***NONE***