Plan Review Stops For Permit 04030820 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-08-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-08-18 |
Time |
09:57 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2004-08-18 |
Time |
09:57 |
Sent To |
PC |
|
Notes |
2004-08-18 00:00:00 | GARAGE DOOR AND ENTRY DOOR PRODUCT | | APPROVAL. FLOOD ZONE REVISION AND | | ENGINEER LETTER TO RESPOND TO PROVISO. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-04-09 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-17 |
Time |
12:42 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2004-04-09 |
Time |
14:03 |
Sent To |
PC |
|
Notes |
2004-04-09 00:00:00 | BUILDING REVIEW PROVISO: | | 1-FLOOD ZONE AO: WILL NEED TO PROVIDE | | THE ELEVATION CERTIFICATE. | | 2-DETAIL E/4 AND RESIDENTIAL NOTES ON | | DRAWING #2 DON'T MATCH. CLARIFY THE | | FASTENER SPACING. SEC. 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. | | 3-TYPICAL WALL SECTION A/4: SPECIFY | | WHERE ARE TABLES 6 AND 8 FOR ROOF | | FASTENERS TAKEN FROM. SEC. 104.2.1.2 | | CITY AMENDMENTS TO FBC 2001. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-04-06 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-03-31 |
Time |
20:14 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2004-04-05 |
Time |
16:39 |
Sent To |
|
|
Notes |
2004-04-05 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1-REVISE ENERGY CALCULATIONS: NEED TO BE | | CALCULATED FOR WORST CASE SCENARIO IF | | IT'S TO BE USED AS TYPICAL FOR ALL | | HOUSES. OR PROVIDE ENERGY CALCULATIONS | | THAT ARE CALCULATED FOR EACH HOUSE | | ACCORDING TO THE ORIENTATION. | | 2-PROVIDE FLORIDA PRODUCT APPROVAL AND | | DRAWINGS FOR ENTRY DOOR THAT MATCH TO | | EACH OTHER. EVERYTHING TO BE BENCHMARK | | OR THERMA TRU. | | 3-PROVIDE FLORIDA PRODUCT APPROVAL COVER | | FOR SLIDING GLASS DOORS AND FIXED | | WINDOWS. AND PROVIDE ONLY THE DWGS FOR | | WINDOWS/DOORS TO BE INSTALLED IN THIS | | HOUSE. | | 4-DETAIL E/4 AND RESIDENTIAL NOTES ON | | DWG #2 DON'T MATCH. CLARIFY SPACING | | OF FASTENERS. | | 5-TYPICAL WALL SECTION A/4. SPECIFY | | WHERE ARE TABLES 6 AND 8 FOR ROOF TILE | | FASTENING TAKEN FROM/ SEC. 104.2.1.2 | | CITY AMENDMENTS TO FBC 2001. | | 6-IMPACT FEES PAID RECEIPT NEED TO HAVE | | A PR NUMBER. CLARIFY WHY AMOUNT PAID | | IS LESS THAN AMOUNT STAMPED ON PLANS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-03-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2004-03-24 |
Time |
16:49 |
Rev Time |
0.45 |
Received By |
jleahy |
Date |
2004-03-29 |
Time |
14:55 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-08-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-17 |
Time |
12:42 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-17 |
Time |
12:42 |
Sent To |
B |
|
Notes |
2004-08-17 00:00:00 | TO JG DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-07-29 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-29 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-29 |
Time |
15:03 |
Sent To |
B |
|
Notes |
2004-07-29 00:00:00 | TO JG DESK/NEW PROVISO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-05-21 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-21 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-21 |
Time |
09:20 |
Sent To |
Z |
|
Notes |
2004-05-21 00:00:00 | REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-04-05 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-03-18 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-03-12 |
Time |
14:15 |
Sent To |
PC |
|
Notes |
2004-03-19 00:00:00 | TO SFD RACK/E | 2004-03-16 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2004-03-24 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2004-03-29 |
Time |
14:56 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2004-03-23 |
Time |
18:52 |
Sent To |
E |
|
Notes |
2004-03-23 00:00:00 | PASS PRIVISO | | 1) REFER TO SECTION 307.2.3 AUXILIARY | | DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE | | INSTALLED UNDER ALL COILS ON WITCH | | CONDENSATION WILL OCCUR. | | 2) RETURN AIR REQUIREMENTS TO COMPLY | | WITH THE FLORIDA BUILDING CODE (M) 2003 | | CHANGES.CHANGES WENT INTO EFFECT JULY 1 | | 2003 | | PLAN REVIEW BY HAROLD MOSER | | (561)805-6732 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-03-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-04-06 |
Time |
15:00 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2004-03-31 |
Time |
20:14 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-03-18 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-21 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-03-18 |
Time |
12:20 |
Sent To |
I |
|
Notes |
|
|