Plan Review Details - Permit 04030785
Plan Review Stops For Permit 04030785
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2004-08-27 Cont ID  
Sent By jgomez Date 2004-08-27 Time 16:40 Rev Time 0.25
Received By jgomez Date 2004-08-27 Time 16:40 Sent To PC
Notes
2004-08-27 00:00:00ENGINEER'S LETTER TO CLARIFY ITEMS ON
 PROVISO.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2004-08-11 Cont ID  
Sent By csiegber Date 2004-08-17 Time 12:43 Rev Time 0.33
Received By jgomez Date 2004-08-11 Time 16:01 Sent To PC
Notes
2004-08-11 00:00:00CHECKLIST:
 PROVIDE INFORMATION REQUESTED ON
 PREVIOUS PROVISO:
 1-DETAIL E/4 AND RESIDENTIAL NOTES ON
 SHEET #2 TO MATCH.
 2-TYPICAL SECTION A4: SPECIFY WHERE ARE
 TABLES 6 AND 8 TAKEN FROM?. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 NOTE: GARAGE DOOR PRODUCT APPROVAL
 SUBMITTED IS OK.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-06-28 Cont ID  
Sent By csiegber Date 2004-07-29 Time 15:02 Rev Time 0.33
Received By jgomez Date 2004-06-28 Time 12:03 Sent To PC
Notes
2004-06-28 00:00:001-FLOOD ZONE REVISION IS OK.
 2-PROVIDE INFORMATION REQUESTED ON
 PROVISO DATED 4-15-04. SEE ATTACHED.
 3-PROVIDE COPIES OF GARAGE DOOR DRAWINGS
 THAT WERE SUBMITTED TO SBCCI FOR
 APPROVAL. NEED DRAWINGS SIGNED AND
 SEALED ON THE DATE NOTED ON SBCCI
 EVALUATION REPORT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-04-15 Cont ID  
Sent By csiegber Date 2004-06-22 Time 14:43 Rev Time 1.00
Received By jgomez Date 2004-04-15 Time 14:54 Sent To PC
Notes
2004-04-15 00:00:00BUILDING REVIEW PROVISO:
 1-FLOOD ZONE AO. NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 2-DETAIL E/4 AND RESIDENTIAL NOTES ON
 DWG #2 DON'T MATCH. CLARIFY ANCHOR
 SPACING. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 3-TYPICAL WALL SECTION A/4: SPECIFY
 WHERE ARE TABLES 6 AND 8 TAKEN FOR
 ROOF TILE FASTENERS TAKEN FROM.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-05 Cont ID  
Sent By pkrauss Date 2004-04-01 Time 10:07 Rev Time 2.00
Received By jgomez Date 2004-04-05 Time 13:34 Sent To PC
Notes
2004-04-05 00:00:00BUILDING REVIEW CHECKLIST:
 1-ENERGY CALCULATIONS ARE NOT CALCULATED
 FOR WORST CASE SCENARIO.THEY CAN'T BE
 SUBMITTED AS TYPICAL FOR THIS MODEL.
 PROVIDE ENERGY CALCULATIONS FOR WORST
 CASE SCENARIO OR PROVIDE ENERGY CALCS
 THAT ARE CALCULATED FOR EACH HOUSE
 ACCORDING TO THE ORIENTATION OF IT.
 2-ENTRY DOOR PRODUCT APPROVAL: DRAWINGS
 DON'T MATCH PRODUCT APPROVAL. DRAWINGS
 ARE FOR "BENCHMARK" & PRODUCT APPROVAL
 COVER IS FOR "THERMA TRU" DOORS.
 3-PROVIDE FLORIDA PRODUCT APPROVAL COVER
 PAGE FOR SLIDING GLASS DOORS AND FIXED
 WINDOWS. AND PROVIDE ONLY THE DWGS FOR
 WINDOWS AND DOORS TO BE INSTALLED IN
 THIS HOUSE.
 4-DETAIL E/4 AND RESIDENTIAL NOTES ON
 DWG #2 DON'T MATCH. DETAIL E/4 CALLS
 FOR 6"O.C. SPACING, WHILE NOTES CALL
 FOR 16"O.C. REVISE AS REQUIRED.
 5-TYPICAL WALL SECTION A/4. SPECIFY
 WHERE ARE TABLES 6 AND 8 FOR ROOF TILE
 FASTENING TAKEN FROM. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-03-25 Cont ID  
Sent By jleech Date 2004-03-20 Time 13:26 Rev Time 0.50
Received By btrobaug Date 2004-03-25 Time 09:21 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-08-17 Cont ID  
Sent By csiegber Date 2004-08-17 Time 12:43 Rev Time 0.00
Received By csiegber Date 2004-08-17 Time 12:43 Sent To B
Notes
2004-08-17 00:00:00TO JG DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-29 Time 15:02 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 15:02 Sent To B
Notes
2004-07-29 00:00:00TO JG DESK/NEW PROVISO

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-22 Cont ID  
Sent By csiegber Date 2004-06-22 Time 14:43 Rev Time 0.00
Received By csiegber Date 2004-06-22 Time 14:43 Sent To B
Notes
2004-06-22 00:00:00TO JG DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-05 Cont ID  
Sent By mmclean Date 2004-03-18 Time 12:36 Rev Time 0.00
Received By csiegber Date 2004-03-12 Time 14:13 Sent To PC
Notes
2004-03-19 00:00:00TO SFD RACK/E
2004-03-16 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-04-01 Cont ID  
Sent By pkrauss Date 2004-04-01 Time 10:07 Rev Time 0.15
Received By pkrauss Date 2004-04-01 Time 10:06 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-03-31 Cont ID  
Sent By btrobaug Date 2004-03-25 Time 10:50 Rev Time 0.30
Received By pkrauss Date 2004-03-31 Time 16:21 Sent To B
Notes
2004-03-31 00:00:00DENIED:
 RETURN AIR JUMPER FROM BEDROOM #3 AND
 THE MASTER BEDROOM ARE NOT SIZED
 PROPERLY.BEDROOM #3 SHALL BE A MINIMUM
 OF 9".THE MASTER BEDROOM SHALL BE
 A MINIMUM OF 14".
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-03-20 Cont ID  
Sent By jleech Date 2004-03-20 Time 13:26 Rev Time 0.25
Received By jleech Date 2004-03-20 Time 13:26 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-18 Cont ID  
Sent By mmclean Date 2004-03-18 Time 12:36 Rev Time 0.00
Received By mmclean Date 2004-03-18 Time 12:36 Sent To I
Notes
***NONE***