Plan Review Details - Permit 04030742
Plan Review Stops For Permit 04030742
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2004-08-12 Cont ID  
Sent By jgomez Date 2004-08-13 Time 09:34 Rev Time 0.33
Received By jgomez Date 2004-08-12 Time 16:54 Sent To PC
Notes
2004-08-13 00:00:00CHECKLIST:
 1-PROVIDE REVISED SURVEY IDENTIFYING
 CORRECT FLOOD ZONE AS REQUIRED ON
 CHECKLIST DATED 6-28-04. SEE ATTACHED
 COPY.
 2-GARAGE DOOR PRODUCT APPROVAL IS OK.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.
2004-08-12 00:00:00CHECKLIST:
 1-PROVIDE REVISED SURVEY

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-06-28 Cont ID  
Sent By csiegber Date 2004-07-29 Time 14:39 Rev Time 0.50
Received By jgomez Date 2004-06-28 Time 15:04 Sent To PC
Notes
2004-06-28 00:00:00REVISION CHECKLIST:
 1-REVISE SURVEY: FIRM ZONE CALLS FOR AO
 AND B ZONE. REVISED SURVEY TO IDENTIFY
 ONLY ONE ZONE.
  
 2-PROVIDE COPIES OF GARAGE DOOR DRAWINGS
 SUBMITTED TO SBCCI FOR APPROVAL. NEED
 DRAWINGS SIGNED AND SEALED ON DATE
 NOTED ON SBCCI EVALUATION REPORT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-05-03 Cont ID  
Sent By csiegber Date 2004-06-22 Time 14:42 Rev Time 0.33
Received By jgomez Date 2004-05-03 Time 11:53 Sent To E
Notes
2004-05-03 00:00:00BUILDING REVIEW PROVISO:
 1-FLOOD ZONE AO: NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-04-16 Cont ID  
Sent By csiegber Date 2004-04-30 Time 10:11 Rev Time 1.00
Received By jgomez Date 2004-04-16 Time 11:59 Sent To PC
Notes
2004-04-16 00:00:00BUILDING REVIEW PROVISO:
 FLOOD ZONE AO: NEED THE ELEVATION
 CERTIFICATE.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-05-05 Cont ID  
Sent By dpalmer Date 2004-05-05 Time 05:25 Rev Time 0.25
Received By dpalmer Date 2004-05-05 Time 05:25 Sent To P
Notes
2004-05-05 00:00:00********* REDLINED/ PROVISO ***********
  
 1)NOTE; PLEASE SEE MAX LOAD FOR 1P20A
 IS 1.9KW. IRRG PUMP AND WASHER SHOWN AT
 2KW?
  
 2)NOTE: PLEASE SEE 220.19, MIN LOAD TO
 BE SHOWN FOR RANGE IS 8KW. SHOWN AS 7.5
  
 SD'S REDLINED TO BE INSTALLED PER NFPA-
 -72 8-1.4.2
  
 REVISE PLANS BEFORE ROUGH.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-04-01 Cont ID  
Sent By jgomez Date 2004-05-03 Time 11:53 Rev Time 0.45
Received By jleahy Date 2004-04-01 Time 13:27 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-29 Time 14:39 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 14:39 Sent To B
Notes
2004-07-29 00:00:00TO JG DESK/NEW PROVISO

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-06-22 Cont ID  
Sent By csiegber Date 2004-06-22 Time 14:42 Rev Time 0.00
Received By csiegber Date 2004-06-22 Time 14:42 Sent To B
Notes
2004-06-22 00:00:00TO JG DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-30 Cont ID  
Sent By csiegber Date 2004-04-30 Time 10:11 Rev Time 0.00
Received By csiegber Date 2004-04-30 Time 10:11 Sent To B
Notes
2004-04-30 00:00:00TO JG DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-16 Cont ID  
Sent By mmclean Date 2004-03-18 Time 12:28 Rev Time 0.00
Received By csiegber Date 2004-03-12 Time 14:17 Sent To PC
Notes
2004-03-19 00:00:00TO SFD RACK/E
2004-03-16 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-05-11 Cont ID  
Sent By pkrauss Date 2004-05-11 Time 14:16 Rev Time 0.30
Received By pkrauss Date 2004-05-11 Time 14:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-03-24 Cont ID  
Sent By jleech Date 2004-05-08 Time 13:08 Rev Time 0.25
Received By hmoser Date 2004-03-24 Time 18:12 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-05-08 Cont ID  
Sent By jleech Date 2004-05-08 Time 13:07 Rev Time 0.25
Received By jleech Date 2004-05-08 Time 13:07 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-04-07 Cont ID  
Sent By dpalmer Date 2004-05-05 Time 05:25 Rev Time 0.25
Received By jleech Date 2004-04-07 Time 17:30 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-18 Cont ID  
Sent By mmclean Date 2004-03-18 Time 12:28 Rev Time 0.00
Received By mmclean Date 2004-03-18 Time 12:28 Sent To I
Notes
***NONE***