Plan Review Details - Permit 04030335
Plan Review Stops For Permit 04030335
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-05-04 Cont ID  
Sent By rmcdouga Date 2004-05-04 Time 08:43 Rev Time 0.00
Received By rmcdouga Date 2004-05-04 Time 08:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-13 Cont ID  
Sent By csiegber Date 2004-04-28 Time 10:02 Rev Time 2.00
Received By rmcdouga Date 2004-04-13 Time 09:26 Sent To  
Notes
2004-04-13 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SPECIFY ON THE PLANS THAT THE DOOR
 FROM THE GARAGE TO CONDITIONED SPACE IS
 REQUIRED TO BE SOLID CORE OR INSULATED.
 SEE FBC 13-603.
  
 3) SPECIFY ON THE PLANS THAT THE WINDOW
 IN BATH #3 WHICH IS WITHIN 3 FEET
 HORIZONTALLY OF A TUB OR SHOWER IS
 REQUIRED TO BE TEMPERED. SEE FBC 2405.2.
  
 4) THE FRONT WALL IS MISSING FROM THE
 FLOOR PLAN ON SHEET 4.
  
 5) EGRESS WINDOWS ARE REQUIRED IN THE
 MASTER BEDROOM AND BEDROOM #3. SEE FBC
 1005.4.
  
 6) SPECIFY THE MATERIAL TO BE USED FOR
 THE DRAFTSTOPPING OF THE FLOOR/CEILING
 ASSEMBLY SEPARATING IT INTO 500 SQFT
 AREAS. INDICATE THEIR APPROXIMATE
 LOCATIONS ON THE FLOOR FRAMING LAYOUT ON
 SHEET 4.
  
 7) SPECIFY THE TREAD WIDTH AND RISER
 HEIGHT ON THE PLANS. SEE FBC 1007.3.1.
  
 8) DETAIL 1 ON SHEET 6 REFERS TO FBC
 2605.5. THIS CODE SECTION DOES NOT EXIST
 PLEASE CORRECT.
  
 9) SPECIFY THE ATTIC LIVE LOAD ON THE
 PLANS. SEE FBC TABLE 1604.1.
  
 10) SPECIFY THE LENGTH/EMBED DEPTH OF
 THE 3/16" TAPCONS IN DETAIL 8 ON SHEET A
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-03-17 Cont ID  
Sent By btrobaug Date 2004-03-17 Time 11:50 Rev Time 0.50
Received By btrobaug Date 2004-03-17 Time 11:18 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-04-28 Cont ID  
Sent By csiegber Date 2004-04-28 Time 10:02 Rev Time 0.00
Received By csiegber Date 2004-04-28 Time 10:02 Sent To B
Notes
2004-04-28 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-13 Cont ID  
Sent By mmclean Date 2004-03-09 Time 11:10 Rev Time 0.00
Received By rmcdouga Date 2004-03-08 Time 12:44 Sent To  
Notes
2004-03-09 00:00:00TO SFD RACK/E
2004-03-08 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-03-23 Cont ID  
Sent By jleech Date 2004-03-20 Time 08:56 Rev Time 0.33
Received By pkrauss Date 2004-03-23 Time 09:15 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-03-20 Cont ID  
Sent By jleech Date 2004-03-20 Time 08:55 Rev Time 0.25
Received By jleech Date 2004-03-20 Time 08:55 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-09 Cont ID  
Sent By mmclean Date 2004-03-09 Time 11:10 Rev Time 0.00
Received By mmclean Date 2004-03-09 Time 11:10 Sent To I
Notes
***NONE***