Plan Review Details - Permit 04030264
Plan Review Stops For Permit 04030264
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date   Cont ID  
Sent By dpalmer Date 2004-04-27 Time 06:20 Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-04-01 Cont ID  
Sent By kstevens Date 2004-03-31 Time 18:24 Rev Time 0.50
Received By lsmith Date 2004-04-01 Time 08:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-05-12 Cont ID  
Sent By dpalmer Date 2004-05-12 Time 14:50 Rev Time 0.25
Received By dpalmer Date 2004-05-12 Time 14:50 Sent To P
Notes
2004-05-12 00:00:00PLANS STAMPED.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-04-27 Cont ID  
Sent By csiegber Date 2004-05-11 Time 15:18 Rev Time 0.25
Received By dpalmer Date 2004-04-27 Time 06:17 Sent To B
Notes
2004-04-27 00:00:00*** NOTE ***
 ELECTRICAL PLAN OK, PLANS NOT STAMPED
 DUE TO PLUMB COMMENTS.
 PLUMB AND ELECTRICAL ARE ON SAME SHEETS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-03-30 Cont ID  
Sent By pschmitz Date 2004-04-25 Time 07:37 Rev Time 0.33
Received By btrobaug Date 2004-03-30 Time 07:12 Sent To P
Notes
2004-03-30 00:00:00 
 PLEASE NOTE THAT THE SIGNATURE OF THE EN
 GINEER IS REQUIRED ON HIS/HER SEAL PER
 61G15-23.002 FLORIDA ADMINISTRATIVE CODE
 INITIALS ARE NOT ACCEPTABLE PER F.B.P.E.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-06-24 Cont ID  
Sent By csiegber Date 2004-06-24 Time 08:21 Rev Time 0.00
Received By csiegber Date 2004-06-24 Time 08:21 Sent To P
Notes
2004-06-24 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-05-11 Cont ID  
Sent By csiegber Date 2004-05-11 Time 15:18 Rev Time 0.00
Received By csiegber Date 2004-05-11 Time 15:18 Sent To E
Notes
2004-05-11 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-14 Time 11:53 Rev Time 0.00
Received By csiegber Date 2004-04-14 Time 11:53 Sent To P
Notes
2004-04-14 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-03-29 Cont ID  
Sent By lsmith Date 2004-03-29 Time 13:57 Rev Time 0.00
Received By lsmith Date 2004-03-29 Time 13:57 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-23 Cont ID  
Sent By mmclean Date 2004-03-26 Time 12:44 Rev Time 0.00
Received By csiegber Date 2004-03-23 Time 11:23 Sent To Z
Notes
2004-03-23 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-03-05 Cont ID  
Sent By csiegber Date 2004-03-05 Time 09:00 Rev Time 0.00
Received By csiegber Date 2004-03-05 Time 09:00 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2004-07-13 Cont ID  
Sent By kstevens Date 2004-07-13 Time 07:54 Rev Time 0.33
Received By kstevens Date 2004-07-13 Time 07:54 Sent To  
Notes
2004-07-13 00:00:00REVISION OK - CHANGED LOCATION OF POOL
 EQUIPMENT/SLAB

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-05-28 Cont ID  
Sent By csiegber Date 2004-06-24 Time 08:21 Rev Time 1.50
Received By kstevens Date 2004-05-26 Time 15:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-04-25 Cont ID  
Sent By dpalmer Date 2004-05-12 Time 14:53 Rev Time 2.00
Received By pschmitz Date   Time   Sent To E
Notes
2004-04-25 00:00:00PLUMBING: DENIED 2ND TIME
 (1) PEVIOUS NOTES 1,2,4 DATED 03-31-04
 NOT ADDRESSED.
 (2) PREVIOUS NOTE BY ZONING DATED 03-08-
 04, DRAWINGS TO SCALE.
 FBC 2001 SEC 104.2
 DRAWINGS AND SPECIFICATIONS.
 TWO OR MORE COPIES OF SPECIFICATIONS,
 AND DRAWINGS DRAWN TO SCALE WITH SUFFI-
 CENT CLARITY AND DETAIL TO INDICATE THE
 NATURE AND CHARACTER OF THE WORK,SHALL
 ACCOMPANY THE APPLICATION FOR A PERMIT.
 (3) BACK FLOW PREVENTER TO BE INSTALLED
 BY A LICENSED PLUMBER WITH A SEPERATE
 PERMIT BEFORE COMMENCING WORK.
 END OF COMMENTS,QUESTIONS 561-805-6692

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-03-31 Cont ID  
Sent By csiegber Date 2004-04-14 Time 11:53 Rev Time 0.50
Received By kstevens Date 2004-03-31 Time 18:24 Sent To B
Notes
2004-03-31 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 2) FBC-2001424.2.6.6.4 MINIMUM OF TWO
 SUCTION INLETS SHALL BE PROVIDED FOR EA
 PUMP. SEPARATED BY A MINIMUM OF 3 FEET
 OR LOCATED ON TWO DIFFERENT PLANES.
 (DETAIL) - MORE INFORMATION REQUIRED -
 INDICATE THE SUCTION INLETS FOR THE 2ND
 PUMP AS ONLY TWO MAIN DRAINS ARE SHOWN.
 3) FBC-2001424.2.7.1 POOL CIRCULATING
 PUMPS SHALL BE EQUIPPED ON THE INLET
 SIDE WITH AN APPROVED TYPE HAIR AND LINT
 STRAINER WHEN USED WITH A PRESSURE FIL-
 TER. (DETAIL OR ADD TO NOTES) - SECOND
 CIRCULATING PUMP SHOWS NO HAIR AND LINT
 STRAINER. PLEASE CLAIRFY.
 4) PIPING SCHEMATIC, SHOWS A SECOND
 MANIFOLD WITH NUMBERS 1, 2, AND 5 BUT
 DOES NOT SHOW WHERE THE SECOND SET OF
 MAIN DRAINS (1), SKIMMER DRAIN LINE (2),
 AND VACUUM CLEANING LINE CONNECT TO A
 PUMP. PLEASE CLAIRFY.
 5)A PROFESSIONAL ENGINEER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS,
 SPECIFICATIONS, REPORTS AND FINAL BID
 DOCUMENTS PROVIDED TO THE OWNER OR THE
 OWNER'S REPRESENTATIVE, OR OTHER DOCU-
 MENTS PREPARED OR ISSUED BY SAID REGIS-
 TRANT AND BEING FILED FOR PUBLIC RECORD.
 THE DATE THAT THE SIGNATURE AND SEAL IS
 AFFIXED AS PROVIDED HEREIN SHALL BE EN-
 TERED ON SAID PLANS, SPECIFICATIONS, RE-
 PORTS, OR OTHER DOCUMENTS IMMEDIATELY
 UNDER THE SIGNATURE OF THE PROFESSIONAL
 ENGINEER, FAC 61G15-23.002(1)
 FS 471.025
 EACH SHEET OF PLANS AND PRINTS WHICH
 MUST BE SEALED UNDER THE PROVISIONS OF
 CHAPTER 471 SHALL BE SEALED, SIGNED AND
 DATED BY THE PROFESSIONAL ENGINEER IN
 RESPONSIBLE CHARGE. FAC 61G15-23.002(2)
 FS 471.025 - INITIALS ARE NOT ACCEPTABLE
 PER FBPE'S RULING.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2004-03-26 Cont ID  
Sent By mmclean Date 2004-03-26 Time 12:44 Rev Time 0.00
Received By mmclean Date 2004-03-26 Time 12:44 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-03-08 Cont ID  
Sent By csiegber Date 2004-03-23 Time 11:23 Rev Time 0.00
Received By mmclean Date 2004-03-08 Time 16:48 Sent To  
Notes
2004-03-08 00:00:00DENIED, NEED TO HAVE DRAWINGS TO SCALE
 & POOL MUST BE 5FT FROM EASEMENT
 (PROPERTY LINE) CALLED CONTR LEFT MSG
 FILE F MM


Account Summary | Usage Policy | Privacy Policy