Plan Review Details - Permit 04030144
Plan Review Stops For Permit 04030144
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2005-10-12 Cont ID  
Sent By mjacobs Date 2005-10-12 Time 07:57 Rev Time 2.50
Received By mjacobs Date 2005-10-12 Time 07:12 Sent To E
Notes
2005-10-12 00:00:001) THIS REVISION HAS TO BE REVIEWED BY
 PLUMBING AND ELECTRIC. PLANS SENT TO
 ELECRIC 'BT' DESK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-05-09 Cont ID  
Sent By mjacobs Date 2005-05-09 Time 09:31 Rev Time 1.00
Received By mjacobs Date 2005-05-09 Time 09:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-03-09 Cont ID  
Sent By alange Date 2005-03-09 Time 07:04 Rev Time 1.50
Received By alange Date 2005-03-08 Time 15:17 Sent To M
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-02-08 Cont ID  
Sent By alange Date 2005-02-08 Time 14:38 Rev Time 2.00
Received By alange Date 2005-02-08 Time 11:43 Sent To  
Notes
2005-02-08 00:00:00DENIED
  
 SEE NOTES 2 THROUGH 8 FROM LAST REVIEW
 NOT YET ADDRESSED.
  
 6.REVISED:MISSING PRODUCT APPROVALS
 FOR GLASS BLOCK,TWO DIFFERENT ROOFING
 PRODUCT APPROVALS SUBMITTED.SUBMIT
 ONLY TWO COPIES OF ONE APPROVAL.
  
 10. SOIL REPORT NOT SEALED.
  
 11.HAND WRITEN NOTE FROM LAST REVIEW.
 SUBMIT AN EMERGENCY EGRESS EASEMENT FOR
 ZERO LOT SIDE.
  
 12.BARBEQUE INFORMATION FOR DCS BUILT
 IN GRILL DOES NOT PERMIT PLACEMENT UNDER
 UNPROTECTED COMBUSTIBLE CONSTRUCTION.
  
 NOTE:SEE ATTACHED REGARDING FLORIDA
 STATUE 553.80(2)(B)ADDITIONAL FEES
 ARE DUE.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION
 AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS
 WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF
 THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES
 CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 ART LANGE
 BUILDING PLAN REVIEW
 TEL: (561)805-6672
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-09-14 Cont ID  
Sent By alange Date 2004-09-14 Time 10:43 Rev Time 1.50
Received By alange Date 2004-09-14 Time 10:43 Sent To  
Notes
2004-09-14 00:00:00DENIED
  
 SEE NOTES 1 - 8 FROM LAST REVIEW NOT
 YET ADDRESSED.
  
 10. SOIL REPORT NOT SEALED.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 ART LANGE
 BUILDING PLAN REVIEW
 TEL: (561)805-6672
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-14 Cont ID  
Sent By btrobaug Date 2004-08-25 Time 13:37 Rev Time 2.66
Received By alange Date 2004-04-14 Time 11:15 Sent To  
Notes
2004-04-14 00:00:00DENIED
 1. BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 3.A-2 GENERAL ARCH. NOTES #8
 "ALL WINDOWS TO HAVE IMPACT GLAZING"
 CONFLICTS WITH S-3 SHUTTERS REQUIRED
 ADJUST NOTES TO REFLECT WHAT YOU HAVE
 PLANNED.
  
 4.BUILDING VALUATION TO LOW BASED
 UPON SBCCI BUILDING VALUATION DATA.
 ADJUSTED VALUATION IS $292,864.
 ADDITIONAL PERMIT FEES OF $432.93 ARE
 DUE.
  
 5.SHEET A5 HAS NOTES THAT REFERENCE
 CODE SECTIONS OF FBD.THIS SHOULD BE
 FBC (FLORIDA BUILDING CODE). PLEASE
 CORRECT.
  
 6.PRODUCT APPROVALS ARE INCOMPLETE.
 A. PLANS SPEC OUT SPANISH "S" TILE.
 PRODUCT APPROVALS ARE SUBMITTED FOR TWO
 DIFFERENT TILES.
 B.SUBMIT ONLY PRODUCT APPROVALS
 NEEDED THERE IS 4 COPIES OF ONE AND ONE
 OF ANOTHER.
 C.SEPERATE ALL SUBMITALS AND PRODUCT
 APPROVALS INTO 2 COMPLETED SECTIONS.
 PLEASE DON'T USE EXCESSIVE AMOUNTS OF
 STAPLES.I REMOVED OVER 75 STAPLES
 BEFORE A PLAN REVIEW COULD BE STARTED.
  
 7.ROOFING CONTRACTOR NOT SIGNED ON.
 A SEPERATE ROOFING PERMIT IS REQUIRED.
  
 8.SUBMIT MANUFACTURERS SPECS AND UL
 LISTING INFORMATION FOR GAS BBQ.
  
 9.SPECIFY THE WELD TYPES AND UPLIFT
 CAPACITIES FOR THE STEEL COLUMNS ON S-4.
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2006-05-08 Cont ID  
Sent By btrobaug Date 2006-05-08 Time 15:23 Rev Time 0.50
Received By btrobaug Date 2006-05-08 Time 15:15 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2006-05-05 Cont ID  
Sent By btrobaug Date 2006-05-05 Time 07:53 Rev Time 0.50
Received By btrobaug Date 2006-05-05 Time 07:33 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2006-04-25 Cont ID  
Sent By btrobaug Date 2006-04-25 Time 07:19 Rev Time 0.75
Received By btrobaug Date 2006-04-24 Time 18:32 Sent To PC
Notes
2006-04-25 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE SERVICE EQUIPMENT , A METER WITH
 A MAIN DISCONNECT MOUNTED NEXT TO IT,
 SHOWN ON THE RISER DO NOT MATCH THE
 METER ONLY SHOWN ON THE PLAN. PLEASE
 INDICATE ON BOTH ACTUAL CONDITIONS.
  
 2} ON PANEL SCHEDULE "A" THE OCP FOR
 PANEL "B" IS 100 AMPS. ON THE RISER IT"S
 50 AMPS, PLEASE CORRELATE.
  
 3} THE POOL EQUIPMENT NOW HAS BEEN MOVED
 SINCE THE LAST REVISION, AND THE A/C
 DISCONNECTS WOULD APPEAR NOT TO HEVRE
 REQUIRED CLEARANCE PER 110.26. PLEASE
 FIELD VERIFY AND INDICATE CORRECT
 LOCATION ON PLAN.
  
 PLEASE VERIFY FIELD CONDITIONS WITH PLAN
 REVISION PRIOR TO RESUBMITTING FOR
 REVIEW.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/805-6731
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-12-23 Cont ID  
Sent By btrobaug Date 2005-12-23 Time 12:49 Rev Time 0.50
Received By btrobaug Date 2005-12-23 Time 12:41 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2005-10-13 Cont ID  
Sent By btrobaug Date 2005-10-13 Time 17:23 Rev Time 0.50
Received By btrobaug Date 2005-10-13 Time 17:09 Sent To P
Notes
2005-10-13 00:00:00 
 PLEASE SUBMIT ELECTRICAL REVISIONS TO
 CORRELATE WITH THE BUILDING REVISIONS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-08-25 Cont ID  
Sent By btrobaug Date 2004-08-25 Time 13:37 Rev Time 0.50
Received By btrobaug Date 2004-08-24 Time 15:34 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-03-19 Cont ID  
Sent By csiegber Date 2004-08-18 Time 12:21 Rev Time 0.75
Received By btrobaug Date 2004-03-19 Time 16:58 Sent To M
Notes
2004-03-19 00:00:00PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} BOTH PANELS ON THE RISER ARE
 DESIGNATED AS "A".
  
 2} THE RISER DIAGRAM INDICATES #3/0
 FEEDERS TO THE SUB PANEL, THE PANEL
 SCHEDULE INDICATES #3 FEEDERS, PLEASE
 CORRELATE.
  
 3} INDICATE THE LOCATION OF THE SERVICE
 EQUIPMENT ON THE PLAN.
  
 4} THE DISCONNECT LOCATION FOR THE
 CONDENSER UNITS ARE IN VIOLATION OF
 110.26.
  
 5} NOTE #9 REFERS TO ALL CONDUCTORS
 BEING A MINIMUM OF #12, THERE ARE #14'S
 ON THE PANEL SCHEDULE, PLEASE
 CORRRELATE.
  
 6} A SMOKE DETECTOR NEEDS TO BE ADDED
 OUTSIDE THE GUEST BEDROOM PER
 8-1.4.1.6.2(2), "IMMEDIATE VICINITY".
  
 7} ONLY THE RECEPTACLES IN THE BEDROOMS
 ARE MARKED AS BEING ARC FAULT
 PROTECTED,NOTE THAT ALL OUTLETS MUST BE
 PER
 210.12, LIGHTS, SMOKE DETECTORS, FANS.
  
 8} A RECEPTACLE MUST BE ADDED ON THE
 KITCHEN COUNTER PER 210.52(C)(1).
  
 9} A RECEPTACLE PER 210.52(A)(1) MUST
 BE ADDED IN THE BREAKFAST ROOM.
  
 10} THERE ARE TWO BEDROOMS LABELED #3 ON
 SHEET E-1.(GUEST BEDROOM).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-05-04 Cont ID  
Sent By adarroug Date 2006-05-04 Time 13:52 Rev Time 0.00
Received By adarroug Date 2006-05-04 Time 13:52 Sent To E
Notes
2006-05-04 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-04-12 Cont ID  
Sent By adarroug Date 2006-04-12 Time 16:31 Rev Time 0.00
Received By adarroug Date 2006-04-12 Time 16:31 Sent To E
Notes
2006-04-12 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-03-03 Cont ID  
Sent By adarroug Date 2006-03-03 Time 15:32 Rev Time 0.00
Received By adarroug Date 2006-03-03 Time 15:32 Sent To P
Notes
2006-03-03 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-10-11 Cont ID  
Sent By adarroug Date 2005-10-11 Time 14:21 Rev Time 0.00
Received By adarroug Date 2005-10-11 Time 14:21 Sent To B
Notes
2005-10-11 00:00:00TO "MJACOBS" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-04-14 Cont ID  
Sent By adarroug Date 2005-04-14 Time 10:53 Rev Time 0.00
Received By adarroug Date 2005-04-14 Time 10:53 Sent To B
Notes
2005-04-14 00:00:00TO "ALANGE" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-04-11 Cont ID  
Sent By adarroug Date 2005-04-11 Time 15:55 Rev Time 0.00
Received By adarroug Date 2005-04-11 Time 15:55 Sent To Z
Notes
2005-04-11 00:00:00TO "Z" BOX/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-03-17 Cont ID  
Sent By adarroug Date 2005-03-17 Time 10:10 Rev Time 0.00
Received By adarroug Date 2005-03-17 Time 10:10 Sent To P
Notes
2005-03-17 00:00:00TO "KSTEVENS" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-02-18 Cont ID  
Sent By adarroug Date 2005-02-18 Time 16:46 Rev Time 0.00
Received By adarroug Date 2005-02-18 Time 16:45 Sent To B
Notes
2005-02-18 00:00:00TO ALANGE DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-07 Cont ID  
Sent By mjacobs Date 2005-02-07 Time 09:49 Rev Time 0.00
Received By mjacobs Date 2005-02-07 Time 09:49 Sent To B
Notes
2005-02-07 00:00:00TO "AL" DESK/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-18 Cont ID  
Sent By csiegber Date 2004-08-18 Time 12:21 Rev Time 0.00
Received By csiegber Date 2004-08-18 Time 12:21 Sent To E
Notes
2004-08-18 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-14 Cont ID  
Sent By mmclean Date 2004-03-12 Time 15:00 Rev Time 0.00
Received By csiegber Date 2004-03-11 Time 11:35 Sent To  
Notes
2004-03-16 00:00:00TO SFD RACK/E
2004-03-11 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-03-09 Cont ID  
Sent By pkrauss Date 2005-03-09 Time 09:23 Rev Time 0.35
Received By pkrauss Date 2005-03-09 Time 07:57 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-03-22 Cont ID  
Sent By jleech Date 2004-03-20 Time 08:51 Rev Time 0.33
Received By pkrauss Date 2004-03-22 Time 13:10 Sent To B
Notes
2004-03-22 00:00:00PROVISO:
 1.AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED PER 2001 FBC(M)
 307.2.3.
  
 2.RETURN AIR REQUIRED FROM THE DEN
 AREA PER 2001 FBC(M) 601.4
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 5 Status P Date 2006-03-09 Cont ID  
Sent By jleech Date 2006-03-09 Time 08:13 Rev Time 0.00
Received By jleech Date 2006-03-09 Time 08:13 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status N Date 2005-11-29 Cont ID  
Sent By jleech Date 2005-11-29 Time 18:22 Rev Time 0.50
Received By jleech Date 2005-11-29 Time 18:22 Sent To  
Notes
2005-11-29 00:00:00PLEASE SUBMIT PLUMBING REVISIONS TO
 CORRELATE WITH BUILDING REVISIONS.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-03-26 Cont ID  
Sent By kstevens Date 2005-03-26 Time 16:29 Rev Time 1.00
Received By kstevens Date 2005-03-26 Time 16:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-03-14 Cont ID  
Sent By gsalfeld Date 2005-03-14 Time 09:05 Rev Time 1.00
Received By gsalfeld Date 2005-03-14 Time 09:05 Sent To E
Notes
2005-03-14 00:00:003/13/05 DENIEDGS
  
 1- BAR SINK NOT SHOWN ON ISOMETRIC.
 2- SHOW TRAPS ON ALL FIXTURES REQUIRED.
 3- LABEL ALL PIPE SIZES.
 4- UTILITY SINK NOT VENTED.
 5- ISOMETRIC SHOWS BATH 3 ON 2ND FLOOR.
 6- SHOW C.O. ABOVE W.M.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-03-20 Cont ID  
Sent By jleech Date 2004-03-20 Time 08:51 Rev Time 0.33
Received By jleech Date 2004-03-20 Time 08:51 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2005-04-12 Cont ID  
Sent By mmclean Date 2005-04-12 Time 15:36 Rev Time 0.00
Received By mmclean Date 2005-04-12 Time 15:36 Sent To I
Notes
2005-04-12 00:00:00APPROVE REVISION (FRONT/GARAGE).

Review Stop Z ZONING
Rev No 1 Status P Date 2004-03-12 Cont ID  
Sent By mmclean Date 2004-03-12 Time 15:00 Rev Time 0.00
Received By mmclean Date 2004-03-12 Time 15:00 Sent To I
Notes
2004-03-12 00:00:00SIDE MUST BE 8FT