Plan Review Details - Permit 04030137
Plan Review Stops For Permit 04030137
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2005-05-05 Cont ID  
Sent By mjacobs Date 2005-05-05 Time 10:49 Rev Time 1.50
Received By mjacobs Date 2005-05-05 Time 09:36 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status N Date 2005-03-18 Cont ID  
Sent By alange Date 2005-03-18 Time 10:04 Rev Time 0.25
Received By alange Date 2005-03-18 Time 09:55 Sent To  
Notes
2005-03-18 00:00:00SAME REVISION SUBMITTED AGAIN.TALKED
 TO CHARLEY AND INSERTED THIS REV WITH
 REVISION ALREADY TO P/U

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-03-11 Cont ID  
Sent By alange Date 2005-03-11 Time 14:22 Rev Time 0.50
Received By alange Date 2005-03-11 Time 14:22 Sent To  
Notes
2005-03-11 00:00:00REV OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-02-07 Cont ID  
Sent By alange Date 2005-02-07 Time 14:35 Rev Time 1.00
Received By alange Date 2005-02-07 Time 14:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-01-11 Cont ID  
Sent By alange Date 2005-01-11 Time 13:16 Rev Time 0.00
Received By alange Date 2005-01-11 Time 08:52 Sent To  
Notes
2005-01-11 00:00:00DENIED
 NOTES FROM LAST TWO REVIEWS NOT
 ADDRESSED:
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 11. GENERAL ARCHITECTS NOTES #8 "ALL
 WINDOWS TO HAVEIMPACT RESISTANT
 GLAZING"
 PRODUCT APPROVALS SUBMITTED ARE NOT FOR
 IMPACT GLAZING.PLEASE REVISE PRODUCT
 APPROVALS OR PLANS.
  
 12.GARDEN COURT AREA, NOTE, ROOM
 ADJACENT TO COURTYARD IS NOT A SLEEPING
 ROOM, EGRESS NOT REQUIRED.
 RECOMMENDATION, CLOSE OFF 3-3 OPENING
 AND LABEL ON PLANS" THIS ROOM NOT TO BE
 USED AS A SLEEPING ROOM".
 OPENINGS ABOVE WALL HEIGHT TO BOTTOM OF
 BEAM EXCEED TABLE 600 CALCULATION FOR
 20% OF OPENINGS.
 TOTAL AREA APPROX. 132SQ. FT.
 OPENINGS AT LEAST 55 SQ. FT.
 RECOMMENDATION,RAISE WALL UP EVEN WITH
 TOPS OF DOORWAY.
 OPTIONS, 1HR GLASS BLOCK COULD BE USED
 IN THIS WALL.
  
 NOTE:SEE FLORIDA STATUTE NOTICE
 ATTACHED REGARDING DESIGN PROFESSIONAL
 DOCUMENTS.
  
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-11-17 Cont ID  
Sent By alange Date 2004-11-17 Time 14:52 Rev Time 2.00
Received By alange Date 2004-11-17 Time 14:52 Sent To M
Notes
2004-11-17 00:00:00DENIED
  
 COMMENTS NOT ADDRESSED FROM LAST
 REVIEW:
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 7.SURVEY AND SITE PLAN DONT MATCH.
  
 11.GENERAL ARCHITECTS NOTES #8
 "ALL WINDOWS TO HAVE IMPACT RESISTANT
 GLAZING"PRODUCT APPROVALS SUBMITTED
 ARE NOT FOR IMPACT GLAZING.
  
 12.GARDEN COURT, TABLR 600 FBC
 CALCULATIONS NOT CORRECT. TOTAL AREA 318
 SQ. FT. X 20% + 63SQFT. ACTUAL OPENINGS
 ARE 91.25 SQ.FT. PLEASE CHANGE AREA TO
 COMPLY WITH THIS SECTION.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-04-13 Cont ID  
Sent By alange Date 2004-04-13 Time 09:14 Rev Time 2.50
Received By alange Date 2004-04-13 Time 09:14 Sent To  
Notes
2004-04-13 00:00:00DENIED
 1. THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY
 COURTHOUSEAND A COPY SUBMITTED TO THIS
 OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3. BASED UPON SBCCI BUILDING VALUATION
 DATA, PROJECT EVALUATION OF $220,000 IS
 TO LOW AND THE REVISED VALUATION IS
 $297,419.ADDITIONAL PERMIT FEES OF
 $781.91 ARE DUE.104.6.5 WEST PALM
 BEACH AMMENDMENT TO THE FBC.
  
 4.WHAT ROOF TILE ARE YOU USING?
 TWO DIFFERENT PRODUCT APPROVALS HAVE
 BEEN SUBMITTED. SPANISH "S" IS
 SPECIFIED ON PLAN.
  
 5.PRODUCT APPROVAL FOR K.D> WINDOWS
 ARE NOT LISTED ON THE DCA PRODUCT
 APPROVAL SITE.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 6.SEPERATE ROOFING PERMIT REQUIRED.
 CONTRACTOR NOT SIGNED ON AT TIME OF
 APPLICATION.
  
 7.SURVEY AND SITE PLAN DON'T MATCH.
  
 8.PRODUCT APPROVALS FOR GLASS BLOCK
 ARE MISSING. SUBMIT 2 COPIES.
  
 9.TOTAL GROSS AREA LISTED ON PLAN IS
 NOT CORRECT.
  
 10.PAGE A-2 CHECK NOTES TO YOU MEAN
 FBC, NOT FBD?CLARIFY
  
 11.GEN ARCH. NOTES # 8 ALL WINDOWS
 ARE TO BE IMPACT RESISTANT. PLEASE
 CLARIFYSINCE IMPACT PROTECTION IS ALSO
 SPEC'D OUT IN OTHER LOCATIONS.
  
 12.GARDEN COURT:TABLE 600
 CALCULATIONS NOT ACCURATE.
 TOTAL AREA 318 SQ. FT. X 20% = 63SQ.FT.
 ALLOWABLE OPENINGS.ACTUAL OPENINGS
 ARE 91.25 SQ. FT..PLEASE CHANGE AREA
 TO COMPLY WITH TABLE 600 ALLOWABLE
 OPENINGS.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2006-01-31 Cont ID  
Sent By btrobaug Date 2006-01-31 Time 13:20 Rev Time 0.50
Received By btrobaug Date 2006-01-31 Time 12:31 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2006-01-30 Cont ID  
Sent By btrobaug Date 2006-01-30 Time 16:04 Rev Time 0.50
Received By btrobaug Date 2006-01-30 Time 14:33 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2005-12-23 Cont ID  
Sent By btrobaug Date 2005-12-23 Time 13:02 Rev Time 0.33
Received By btrobaug Date 2005-12-23 Time 13:02 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-12-02 Cont ID  
Sent By btrobaug Date 2005-12-02 Time 07:57 Rev Time 0.50
Received By btrobaug Date 2005-12-02 Time 07:08 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-10-13 Cont ID  
Sent By btrobaug Date 2005-10-13 Time 17:57 Rev Time 0.50
Received By btrobaug Date 2005-10-13 Time 17:35 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-11-08 Cont ID  
Sent By btrobaug Date 2004-11-08 Time 18:21 Rev Time 0.75
Received By btrobaug Date 2004-11-08 Time 17:46 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-03-26 Cont ID  
Sent By jleech Date 2004-03-20 Time 12:00 Rev Time 0.45
Received By btrobaug Date 2004-03-25 Time 09:11 Sent To M
Notes
2004-03-25 00:00:001)BOTH PANELS ARE SHOWN AS A
  
 2)RISER SHOWS 3/0S PANEL SHOWS #3
  
 3)SERVICE LOCATION NOT SHOWN
  
 4)AC DISC NOT TO 110.26
  
 5)NOTE #9 NEEDS TO BE CHANGED12 MIN
  
 6)SD OUTSIDE GEST ROOM TO FAR AWAY
  
 7)FANS LIGHTS AND SD TO BE AFCI
  
 8)OUTLET MISSING IN BREAKFAST ROOM
  
 9)TWO BEDROOM 3S ON PLANS
  
 10) NO OUTLET ON THE FRONT OF THE HOUSE

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2006-03-03 Cont ID  
Sent By adarroug Date 2006-03-03 Time 12:14 Rev Time 0.00
Received By adarroug Date 2006-03-03 Time 12:14 Sent To P
Notes
2006-03-03 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2006-01-28 Cont ID  
Sent By adarroug Date 2006-01-28 Time 16:34 Rev Time 0.00
Received By adarroug Date 2006-01-28 Time 16:34 Sent To E
Notes
2006-01-28 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2005-12-01 Cont ID  
Sent By adarroug Date 2005-12-01 Time 16:18 Rev Time 0.00
Received By adarroug Date 2005-12-01 Time 16:18 Sent To E
Notes
2005-12-01 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2005-10-11 Cont ID  
Sent By adarroug Date 2005-10-11 Time 14:26 Rev Time 0.00
Received By adarroug Date 2005-10-11 Time 14:26 Sent To E
Notes
2005-10-11 00:00:00TO "E" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2005-04-28 Cont ID  
Sent By adarroug Date 2005-04-28 Time 11:18 Rev Time 0.00
Received By adarroug Date 2005-04-28 Time 11:18 Sent To B
Notes
2005-04-28 00:00:00TO "ALANGE" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-03-17 Cont ID  
Sent By adarroug Date 2005-03-17 Time 10:38 Rev Time 0.00
Received By adarroug Date 2005-03-17 Time 10:38 Sent To B
Notes
2005-03-17 00:00:00TO "AL" BOX/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-03-03 Cont ID  
Sent By mjacobs Date 2005-03-03 Time 09:37 Rev Time 0.00
Received By mjacobs Date 2005-03-03 Time 09:37 Sent To B
Notes
2005-03-03 00:00:00TO "AL" DESK/REV.

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-02-02 Cont ID  
Sent By adarroug Date 2005-02-02 Time 13:51 Rev Time 0.00
Received By adarroug Date 2005-02-02 Time 13:44 Sent To P
Notes
2005-02-02 00:00:00TO "P"BOX/RESUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-01-13 Cont ID  
Sent By mjacobs Date 2005-01-13 Time 16:44 Rev Time 0.00
Received By mjacobs Date 2005-01-13 Time 16:44 Sent To P
Notes
2005-01-13 00:00:00TO "P" BOX/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-12-15 Cont ID  
Sent By mjacobs Date 2004-12-15 Time 16:44 Rev Time 0.00
Received By mjacobs Date 2004-12-15 Time 16:43 Sent To P
Notes
2004-12-15 00:00:00SENT TO "P" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-14 Cont ID  
Sent By mjacobs Date 2004-12-14 Time 13:29 Rev Time 0.00
Received By mjacobs Date 2004-12-14 Time 13:29 Sent To P
Notes
2004-12-14 00:00:00SENT TO "Z" BOX/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-11-05 Cont ID  
Sent By csiegber Date 2004-11-05 Time 13:30 Rev Time 0.00
Received By csiegber Date 2004-11-05 Time 13:30 Sent To E
Notes
2004-11-05 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-04-13 Cont ID  
Sent By mmclean Date 2004-03-12 Time 15:14 Rev Time 0.00
Received By csiegber Date 2004-03-11 Time 11:36 Sent To  
Notes
2004-03-16 00:00:00TO SFD RACK/E
2004-03-11 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2005-01-31 Cont ID  
Sent By prafter Date 2005-01-31 Time 11:22 Rev Time 1.00
Received By prafter Date 2005-01-31 Time 11:22 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2005-01-10 Cont ID  
Sent By pkrauss Date 2005-01-10 Time 06:20 Rev Time 0.35
Received By pkrauss Date 2005-01-07 Time 16:37 Sent To B
Notes
2005-01-07 00:00:00DENIED:
 1.PLAN SHEET M-1 RETURN AIR FROM
 AHU-1
 INDICATES 10" INTO A DISTRIBUTION BOX
 WITH TWO 16" FROM THE OTHER ROOMS.
 PLEASE CLARIFY RATIONALE FOR THIS
 DISTRIBUTION LAYOUT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2004-11-22 Cont ID  
Sent By pkrauss Date 2004-11-22 Time 08:24 Rev Time 0.45
Received By pkrauss Date 2004-11-22 Time 08:24 Sent To P
Notes
2004-11-22 00:00:00DENIED:
 1.RETURN AIR NOT INDICATED FOR THE
 DEN/STUDY AREA.
  
 2.RETURN AIR FROM AHU-2; TWO BRANCH
 LINES INDICATED FROM THE RETURN, BUT
 SHOW A SUPPLY SYMBOL.
  
 3.RETURN AIR IS INDICATED FROM THE
 LINEN CLOSET.IS THIS CORRECT?
  
 4.SEER INDICATED ON THE PLAN IS A 12
 SEER RATING.ACCORDING TO THE ENERGY
 CALCULATIONS THE SEER SHALL BE A MINIMUM
 OF 13 SEER.
  
 5.NOTE 21 ON PLAN SHEET M-1 INDICATES
 ONLY A 10.5 SEER MINIMUM.THE SEER CAN
 NOT BE LESS THAN THE ENERGY CALCS
 REQUIRE.
  
 AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED PER 2001 FBC(M)
 307.2.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-04-01 Cont ID  
Sent By btrobaug Date 2004-03-26 Time 06:43 Rev Time 0.30
Received By pkrauss Date 2004-04-01 Time 07:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 6 Status P Date 2006-03-08 Cont ID  
Sent By jleech Date 2006-03-08 Time 15:28 Rev Time 0.00
Received By jleech Date 2006-03-08 Time 15:28 Sent To  
Notes
2006-03-08 00:00:00AS BUILTS

Review Stop P PLUMBING
Rev No 5 Status P Date 2005-02-05 Cont ID  
Sent By pschmitz Date 2005-02-05 Time 05:55 Rev Time 0.00
Received By pschmitz Date 2005-02-05 Time 05:55 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2005-01-28 Cont ID  
Sent By kstevens Date 2005-01-28 Time 11:00 Rev Time 0.33
Received By kstevens Date 2005-01-28 Time 11:00 Sent To M
Notes
2005-01-28 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA STATUTES
  
 A) FROM THE PREVIOUS REVIEW:
 BATH #3 TUB IS NOT VENTED. 902.1
 BATH #2 SHOWER IS NOT VENTED. 902.1
 MASTER BATH SHOWER REQUIRES A TRAP.
 1002.1
 B) NEW SHEETS REQUIRED FOR P-1 AND P-2
 SHOWING ALL CHANGES. HAND DRAWN
 CORRECTIONS ON THE PLANS ARE NOT
 ACCEPTABLE. SECTION 104.2.1.3.
 C) SEE ATTACHED SHEET CONCERNING THE
 DESIGN PROFESSIONAL AND FS 552.80(2)(B)
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-12-28 Cont ID  
Sent By kstevens Date 2004-12-28 Time 15:12 Rev Time 1.00
Received By kstevens Date 2004-12-28 Time 15:12 Sent To M
Notes
2004-12-28 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT P-2 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS. SECTION
 104.2.1.
 A) WASH MACHINE IS NOT VENTED. SECTION
 901.2.1.
 B)BATH #3 TUB IS NOT VENTED AND
 REQUIRES A TRAP. SECTIONS 901.2.1 AND
 1002.1.
 C) BATH #2 IS LABELED AS BATH #3 AND
 THE TUB IS NOT VENTED AND REQUIRES A
 TRAP. SECTIONS 901.2.1 AND 1002.1.
 D) MASTER BATH BIDET NOT VENTED AND
 REQUIRES A TRAP. SECTIONS 901.2.1 AND
 1002.1.
 2) SEE EXAMPLE OF A SANT. RISER DIAGRAM
 THAT WILL MEET THE CODE REQUIREMENTS ON
 ATTACHED SHEETS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-11-24 Cont ID  
Sent By kstevens Date 2004-11-24 Time 05:57 Rev Time 0.50
Received By kstevens Date 2004-11-24 Time 05:57 Sent To Z
Notes
2004-11-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 SECTION 1
  
 1) SHT P-1 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS, NOR DOES IT
 REFLECT THE FLOOR PLAN.
 A) BATH #3 TUB NOT VENTED, AND A TRAP
 IS REQUIRED. SECTIONS 902.1 & 1002.1
 B) WASH MACHINE AS SHOWN IS AN "S' TRAP
 AND IS NOT APPROVED. A VENT IS REQUIRED
 AS WELL AS A STANDPIPE AND A CLEANOUT 4
 FEET ABOVE THE FLOOR ON THE W/M STACK.
 SECTION 708.10, 902.1, 1002.1, &
 1002.3(5)
 C) WET BAR SINK IS NOT VENTED AND PIPED
 AS SHOWN IS AN "S" TRAP WHICH IS NOT
 APPROVED. SECTION 902.1 & 1002.3(5).
 D) TRAP REQUIRED FOR SHOWER IN MASTER
 BATH, AND BIDET SHOWN ON THE FLOOR PLAN
 IS NOT ON THE RISER DIAGRAM. SECTIONS
 1002.1 & 1104.2.1.
 E) SHOWER IN GUEST BATH IS NOT VENTED,
 AND REQUIRES A TRAP. SECTIONS 902.1 &
 1002.1
 F) INFORMATIONAL: IF KITCHEN SINK IS AN
 ISLAND SINK, THEN AN AIR ADMITTENCE
 VALVE MAY BE USED IF A VENT THROUGH THE
 ROOF CAN NOT BE INSTALLED. SECTION 917
  
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-03-20 Cont ID  
Sent By jleech Date 2004-03-20 Time 12:00 Rev Time 0.33
Received By jleech Date 2004-03-20 Time 12:00 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2005-02-01 Cont ID  
Sent By mmclean Date 2005-02-01 Time 12:29 Rev Time 0.00
Received By mmclean Date 2005-02-01 Time 12:29 Sent To I
Notes
2005-02-01 00:00:00APPROVING REVISION, NO CHANGES TO FIRST
 SURVEY. MUST PULL SEPERATE PERMIT FOR
 POOL/DECK OR SCREEN ENCLOSURE.

Review Stop Z ZONING
Rev No 3 Status P Date 2004-12-15 Cont ID  
Sent By mmclean Date 2004-12-15 Time 16:24 Rev Time 0.00
Received By mmclean Date 2004-12-15 Time 16:24 Sent To I
Notes
2004-12-15 00:00:00MUST PULL SEPERATE PERMIT FOR
 POOL/DECK/SCREEN ENCLOSURE

Review Stop Z ZONING
Rev No 2 Status F Date 2004-12-01 Cont ID  
Sent By mmclean Date 2004-12-01 Time 10:54 Rev Time 0.00
Received By mmclean Date 2004-12-01 Time 10:54 Sent To PC
Notes
2004-12-01 00:00:00PETER PICKED UP PLANS BEFORE ZONING CAN
 REVIEW.ZONING COMMENTS WERE NOT
 ADDRESSED. GIVEN TO PEGGY MM

Review Stop Z ZONING
Rev No 1 Status F Date 2004-03-12 Cont ID  
Sent By mmclean Date 2004-03-12 Time 15:13 Rev Time 0.00
Received By mmclean Date 2004-03-12 Time 15:13 Sent To I
Notes
2004-03-12 00:00:00DENIED, SURVEY & SITE PLAN DOES NOT
 MATCH