Plan Review Stops For Permit 04030098 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-04-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-04-26 |
Time |
10:13 |
Rev Time |
1.25 |
Received By |
jwitmer |
Date |
2004-04-26 |
Time |
08:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-04-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-04-03 |
Time |
11:09 |
Rev Time |
0.75 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2004-04-03 00:00:00 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BUILDING PLAN REVIEW | | PERMIT: 04030098 | | ADD: 1450 CENTREPARK BLVD # 350 | | CONT: BURKHARDT | | TEL: (561)718-2602 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | ITIONS, EXIT ENCLOSURES, AND FIRE | | RATED WALLS REQUIRED TO HAVE PROTECTED | | OPENINGS SHALL BE EFFECTIVELY AND | | PERMANETLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | CEILING CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | PROTECT ALL OPENINGS". | | | | 3) DOOR# 305,SHOULD SWING IN THE DIREC- | | TION OF EGRESS 1012.2. | | | | 4) DOORS 318 (BOTH) ARE NOT LABELED WITH | | A MINIMUM DIMENSION ON THE PULL/ LATCH | | SIDE OF THE DOOR: | | 11-4.13.6 MANEUVERING CLEARENCES | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | AT DOORS THAT ARE NOT AUTOMATIC OR | | POWER-ASSISTED SHALL BE AS SHOWN IN | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | IN THE REQUIRED CLEARENCES SHALL BE | | CLEAR & LEVEL. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-04-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-04-27 |
Time |
13:25 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-04-27 |
Time |
13:24 |
Sent To |
|
|
Notes |
2004-04-27 00:00:00 | LTR FOR CALCS CLEARED PROVISO. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-04-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-04-13 |
Time |
19:10 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2004-04-13 |
Time |
19:10 |
Sent To |
|
|
Notes |
2004-04-13 00:00:00 | ********** NOTES/ PROVISO *********** | | | | 1)NOTE: PLEASE SEE LOAD CALCULATIONS, | | PLEASE CORRELATE LOADS FOR PANELS "K" & | | "P" TO T-1. PLEASE ADJUST FINAL LOADS | | FOR PANELS "A" ETC. | | | | PLEASE SUBMIT THE ABOVE CHANGES AND ANY | | OTHER REVISIONS BEFORE ROUGH ELECTRICAL | | INSPECTION IS CALLED IN. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-03-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-03-09 |
Time |
06:18 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-03-09 |
Time |
06:18 |
Sent To |
|
|
Notes |
2004-03-09 00:00:00 | **** UNSAT **** | | | | 1)NOTE: PLEASE SEE FIRE REVIEW AS THEY | | WILL HAVE AN AFFECT ONELECTRICAL PLANS. | | | | 2)NOTE: PLEASE CLARIFY SIZE AND # OF | | CONDUCTORS ON SECONDARY SIDE OF TRANS- | | -FORMER. SHOWS 3-1/0'S, NEUTRAL? | | PLEASE CLARIFY WHAT WILL LIMIT THE LOAD | | ON LOAD SIDE OF X-FORMER FOR RATING OF | | 1/0'S? PLEASE SEE 240.21 FOR TAPPED | | CONDUCTORS. | | | | 3)NOTE: PLEASE CLARIFY TYPE OF EM LTS | | BEING USED. ELETRICAL LEGEND MENTIONS | | FLOURESCENT FIXTURES BEING WIRED TO AN | | EMERGENCY CIRCUIT.? PLEASE CLARIFY | | PLANS DO NOT SEEM TO INDICATE AN EM | | PANEL OR EM SOURCE? | | PLEASE SEE 700.12,700.12E . | | | | 4)NOTE: PLEASE CLARIFY CONTINUOUS LOADS | | AT 125%. 215.3,230.42 ETC | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-04-08 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2004-04-08 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2004-04-08 |
Time |
14:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2004-03-04 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-03-04 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-03-04 |
Time |
13:03 |
Sent To |
|
|
Notes |
2004-03-04 00:00:00 | 1) DOES DOOR 305 SWING IN THE PROPER | | DIRECTION. | | | | 2) ANOTHER ILLUMINATED EXIT SIGN IS | | NEEDED TO DIRECT PERSONS THROUGH | | OPEN WORK ROOM 305. | | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | FOR FIRE ALARM AND FIRE SPRINKLER | | REMODEL. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-04-08 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-08 |
Time |
08:00 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-08 |
Time |
08:00 |
Sent To |
|
|
Notes |
2004-04-08 00:00:00 | TO COMM BD#13 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-04-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-04-03 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2004-03-03 |
Time |
08:01 |
Sent To |
PC |
|
Notes |
2004-03-03 00:00:00 | TO COMM BD#12 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2004-03-24 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-03-24 |
Time |
16:28 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2004-03-24 |
Time |
15:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-04-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-04-21 |
Time |
13:31 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-04-21 |
Time |
13:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-03-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-03-13 |
Time |
06:31 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-03-13 |
Time |
06:31 |
Sent To |
|
|
Notes |
2004-03-13 00:00:00 | PASSED/PROVISO | | | | | | WATER HAMMER ARRESTOR SHALL BE LOCATED | | NEAR THE ICE MAKER |
|
|