Plan Review Stops For Permit 04020477 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-03-12 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-02-28 |
Time |
12:33 |
Rev Time |
2.50 |
Received By |
rmcdouga |
Date |
2004-03-12 |
Time |
15:39 |
Sent To |
|
|
Notes |
2004-03-12 00:00:00 | BUILDING PROVISO | | | | 1) SUBMIT A REVISED KEY PLAN AND | | INSTALLATION SCHEDULE THAT CORRESPONDS | | WITH THE ARCHITECTURAL PLANS PRIOR TO | | INSTALLING. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-07-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-07-07 |
Time |
11:38 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-07-07 |
Time |
11:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2004-06-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-02 |
Time |
13:18 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-06-17 |
Time |
18:26 |
Sent To |
P |
|
Notes |
2004-06-17 00:00:00 | ********* UNSAT *********** | | | | 1)NOTE: PLEASE SEE ONLY ONE COPY OF | | SHEET E-1E WAS SUBMITTED. | | | | 2)NOTE: PLEASE SEE GFI IN MASTER BATH | | IS REQUIRED TO WITHIN 3' OF SINK. | | 210.52D | | PLEASE SEE THIS IS THE FIRST SET OF FULL | | SIZE PLANS THAT CORRELATE W/ SCALE. | | | | 3)NOTE: PLEASE SEE SD'S ARE BEING SHOWN | | ON TWO SEPARATE CIRCUITS, YET THESE ARE | | REQUIRED TO BE WIRED "INLINE". THIS IS | | NOT POSSIBLE WITH TWO CIRCUITS GOING TO | | THE SAME DEVICES. NFPA-72 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-02-23 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-14 |
Time |
13:54 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-02-23 |
Time |
14:14 |
Sent To |
M |
|
Notes |
2004-02-23 00:00:00 | REDLINED | | 210.12, 2002 NEC. ALL "OUTLETS". |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-07-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-02 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-02 |
Time |
13:18 |
Sent To |
E |
|
Notes |
2004-07-02 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-06-14 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-14 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-06-14 |
Time |
13:54 |
Sent To |
E |
|
Notes |
2004-06-14 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-03-12 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-02-13 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2004-02-12 |
Time |
11:38 |
Sent To |
|
|
Notes |
2004-02-13 00:00:00 | TO SFD RACK/E | 2004-02-12 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2004-02-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-02-23 |
Time |
14:15 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2004-02-28 |
Time |
09:27 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2004-06-28 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-06-28 |
Time |
14:43 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-06-28 |
Time |
14:43 |
Sent To |
|
|
Notes |
2004-06-28 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 1 | | | | 1) NO CHANGES TO STAMPED SET OF PLANS ON | | FILE ARE NOTED ON REVISION. PLEASE IN- | | DICATE REVISIONS WITH CLOUDS AND TRI- | | ANGLES WITH NUMBERS. STAMPED SET OF | | PLANS SHOW REVISION #2, AND REVISION | | ALSO SHOWS REVISION #2. PLEASE CLARIFY. | | MINIMUM OF TWO SETS OF REVISIONS ARE RE- | | QUIRED. ONLY ONE SET HAS BEEN SUBMITTED | | FOR REVIEW. SECTION 104.2.1. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-02-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-17 |
Time |
18:41 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2004-02-28 |
Time |
12:33 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-02-13 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-02-13 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-02-13 |
Time |
15:03 |
Sent To |
I |
|
Notes |
|
|