Plan Review Stops For Permit 04020057 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2004-10-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-10-13 |
Time |
14:06 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-10-13 |
Time |
14:06 |
Sent To |
E |
|
Notes |
2004-10-13 00:00:00 | REVISION A1 DATED 10/5/4 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2004-07-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-05 |
Time |
15:08 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-07-16 |
Time |
17:46 |
Sent To |
E |
|
Notes |
2004-07-16 00:00:00 | REVISED A1 & A2 ADDRESSING PROVISOS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2004-06-30 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-12 |
Time |
13:49 |
Rev Time |
1.50 |
Received By |
shill |
Date |
2004-06-30 |
Time |
17:25 |
Sent To |
|
|
Notes |
2004-06-30 00:00:00 | PROVISO - REVISE SHEETS AS NOTED ON | | PLAN | | | | TABLE 600 FOR EAST SIDE | | REVISE AS PER HISTORIC | | ATTACHMENT FOR HANDRAIL, REVISED WALL | | SECTION |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2004-06-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-06-29 |
Time |
15:49 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2004-06-29 |
Time |
15:48 |
Sent To |
|
|
Notes |
2004-06-29 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | 2.)HISTORIC APPROVAL REQUIRED.PLEASE | | HAVE THE PLANS STAMPED BY HISTORIC. | | | | 3.)SEE THE PREVIOUS LISTS.HOW WILL | | THE HANDRAIL BE FASTENED TO COMPLY | | WITH FBC1608.2?IN OTHER WORDS, HOW | | WILL YOU ATTACH THIS TO THE WALL?THIS | | CORRECTION HAS BEEN ON EACH LIST; PLEASE | | HAVE THE ENGINEER CALL ME IF HE DOESN'T | | UNDERSTAND THE CORRECTION. | | | | 4.)CONNECTOR MTS37 ISN'T IN THE | | CATALOG.YOU GAVE A SPEC SHEET FOR | | MST37.FASTENING STILL CONFLICTS. | | PLEASE SEE ATTACHED.FASTENING FOR SP5 | | ALSO CONFLICTS (SEE ATTACHED).CHECK | | ALL CONNECTORS.PLEASE HAVE THE | | ENGINEER CONTACT ME IF HE DOES NOT | | UNDERSTAND THIS CORRECTION AS IT HAS | | BEEN MADE 3 TIMES WITHOUT BEING PROPERLY | | CORRECTED. | | | | 5.)ALL OF THE OTHER PLANS SUBMITTED | | REFERRED TO FBC2001.NOW THE PLANS | | HAVE BEEN CHANGED TO FBC2002.THE | | GOVERNING CODE IS STILL FBC2001, PLEASE | | CORRECT. | | | | 6.)A 4X FEE HAS BEEN CHARGED PER | | FS553.80(2)(B). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2004-06-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-06-03 |
Time |
16:53 |
Rev Time |
2.00 |
Received By |
shill |
Date |
2004-06-03 |
Time |
16:53 |
Sent To |
|
|
Notes |
2004-06-03 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | 2.)HISTORIC APPROVAL REQUIRED.PLEASE | | HAVE THE PLANS STAMPED BY HISTORIC. | | | | 3.)THE ENGINEER'S LICENSE NUMBER IS | | TO BE PRINTED ON EACH SHEET, FAC61G15-23 | | 002. | | | | 4.)SEE PREVIOUS LISTS.HOW WILL THE | | HANDRAIL BE FASTENED TO COMPLY WITH | | FBC1608.2?YOU CANNOT JUST LIST A | | CODE SECTION; YOU MUST GIVE A | | SPECIFICATION AS TO HOW IT WILL BE | | BUILT WHICH IS TO BE IN COMPLIANCE WITH | | THIS CODE SECTION.DO NOT LIST CODE, | | PROVIDE SPECS. | | | | 5.)SEE PREVIOUS LISTS.FLORIDA | | STATEWIDE, LOCAL OR SITE SPECIFIC | | PRODUCT APPROVALS REQUIRED. | | WWW.FLORIDABUILDING.ORG (PRODUCT | | APPROVAL, SEARCH PRODUCT APPROVAL). | | I HAVE PRINTED ONE AS A SAMPLE.ANY | | PRODUCT APPROVALS NOT SUBMITTED | | PROPERLY BEFORE PERMIT ISSUANCE WILL | | REQUIRE SEPARATE PERMITS WITH SEPARATE | | FEES.SUBMIT TWO COPIES OF ALL PRODUCT | | APPROVALS. | | | | 6.)SEE PREVIOUS LISTS, PROVIDE | | DESIGN UPLIFT INFORMATION. | | | | 7.)PROVIDE MANUFACTURER SPECS FOR | | MTS30.THE FASTENING STILL CONFLICTS | | WITH MY CATALOG, PERHAPS YOU HAVE | | OTHER INFORMATION.CONFIRM THAT THE | | SPECS ARE CONSISTENT WITH THE PLAN | | BEFORE RESUBMITTAL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-04-21 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-05-25 |
Time |
11:38 |
Rev Time |
1.50 |
Received By |
shill |
Date |
2004-04-20 |
Time |
12:43 |
Sent To |
Z |
|
Notes |
2004-04-20 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)SEE PREVIOUS LIST, COMMENTS | | 2,6,7, SECOND PART OF 8, 9,10, 12, AND | | 15.A COPY HAS BEEN PROVIDED. | | | | 2.)SEE PREVIOUS LIST, #10.THE | | FLORIDA STATEWIDE, LOCAL OR SITE | | SPECIFIC PRODUCT APPROVAL IS REQUIRED | | FOR THE WINDOWS, DOORS AND SHUTTERS | | IN ADDITION TO THE TEST REPORTS | | PROVIDED.PROVIDE A LIST OF ALL | | CONNECTORS WITH THE FLORIDA PRODUCT | | APPROVAL.FAC9B-72, | | WWW.FLORIDABUILDING.ORG | | | | 3.)PROVIDE THE DISTANCE BETWEEN THE | | TWO BUILDINGS.SHOW COMPLIANCE WITH | | FBC TABLE 600.PROVIDE AN ELEVATION OF | | THE EAST SIDE OF THE PORTION OF THE | | BUILDING (MAIN RESIDENCE) THAT FACES | | THE 2 STORY ACCESSORY BUILDING. | | | | 4.)COMMENT #15 WAS APPARENTLY | | ADDRESSED BY SHOWING PRESSURES OF | | +50/-53 ON THE PLAN (A1), BUT THE NOTES | | STILL INDICATE 57 (TWO STORY). | | | | 5.)NAILING FOR SIMPSON MTS30 | | CONFLICTS WITH THE CATALOG; REVISE. | | CHECK ALL CONNECTORS. | | | | 6.)SEPARATE PERMITS REQUIRED. | | | | 7.)SEE ATTACHED FS553.80(2)(B). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-03-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-04-15 |
Time |
18:32 |
Rev Time |
4.00 |
Received By |
shill |
Date |
2004-03-11 |
Time |
13:01 |
Sent To |
|
|
Notes |
2004-03-11 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | 2.)HISTORIC APPROVAL REQUIRED. | | | | 3.)IMPROVEMENTS OVER 50% MUST COMPLY | | WITH FBC3401.7.2.6; NOTE ON PLAN. | | | | 4.)PROVIDE A SURVEY FOR THIS PROPERTY. | | | | 5.)THE ENGINEER'S LICENS NUMBER IS TO | | BE PRINTED ON EACH SHEET, FAC61G15-23.00 | | 2. | | | | 6.)THE STAIR DETAIL 3-A1 DOES NOT | | COMPLY WITH FBC1007.3.1(1).DO THESE | | DIMENSIONS INDICATE EXISTING | | CONDITIONS?SEE FBC1001.3. | | | | 7.)A1, SCOPE OF BUILDING WORK | | INDICATES AN UPSTAIRS KITCHEN.IS THIS | | CORRECT?NONE IS SHOWN ON THE FLOOR | | PLAN. | | | | 8.)3-A1, HANDRAIL IS TO COMPLY WITH | | FBC1007.5 (34-38" ABOVE TREAD).ALSO | | MUST COMPLY WITH FBC1608.2.HOW WILL | | THE RAIL BE FASTENED TO COMPLY WITH | | FBC1608.2? | | | | 9.)3-A1 SHOWS A STRAP SECURED TO | | A SLAB, CONFLICTS WITH THE OTHER DETAILS | | WHICH SHOW WOOD. | | | | 10.) FLORIDA STATEWIDE, LOCAL OR SITE | | SPECIFIC PRODUCT APPROVALS REQUIRED. | | WWW.FLORIDABUILDING.ORG.PROVIDE A LIST | | OF ALL CONNECTORS WITH FLORIDA PRODUCT | | APPROVAL NUMBERS. | | | | 11.)CORNER FRAMING DETAIL, APPLICATION | | CONFLICTS WITH USP CATALOG FOR RS100. | | ADDRESS. | | | | 12.)PROVIDE DESIGN UPLIFT INFORMATION. | | | | 13.)SPECIFY ALL CONNECTORS, | | CONTINUOUS FROM THE FOUNDATION THROUGH | | THE ROOF, ON ALL DETAILS. | | | | 15.)THE DOOR PRODUCT APPROVAL HAS A | | LIMITATION OF +50/-53.IT APPEARS THAT | | THE DESIGN PRESSURE FOR THIS OPENING | | IS -57. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2004-10-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-10-14 |
Time |
17:04 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-10-14 |
Time |
17:04 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2004-07-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-10-13 |
Time |
14:06 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-07-20 |
Time |
08:09 |
Sent To |
|
|
Notes |
2004-07-20 00:00:00 | RESTAMP ONLY |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-06-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-07-16 |
Time |
17:54 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-06-16 |
Time |
16:45 |
Sent To |
|
|
Notes |
2004-06-16 00:00:00 | ***REDLINED *** | | | | PLANS STILL SHOWS AN EQUIPMENT GROUNDING | | FROM METER TO MAIN. | | THIS SHALL NOT BE INSTALLED. 250.24/250. | | 6 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2004-05-14 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-14 |
Time |
15:10 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-05-14 |
Time |
06:39 |
Sent To |
P |
|
Notes |
2004-05-14 00:00:00 | *********** UNSAT *********** | | | | 1)NOTE: PLEASE SEE PLANS STILL HAVE | | PLACES WHERE 1999 NEC IS REFERENCED? | | | | 2)NOTE: PLEASE SEE FAC 61G15-23.002 | | PLEASE INCLUDE ALL INFORMATION ON TITLE | | BLOCK FOR ENGINEER. THIS IS REQ'D TO BE | | PRINTED ON PLANS. PLEASE ALSO SEE FS | | 471.025, A SIGNATURE IS REQ'D, PER | | FS AND FBPE'S INITIALS ARE NOT PERMITTED | | PLEASE NOTE: THIS IS TO PROTECT THE | | ENGINEER/ FIRMS. | | SIGNATURE INFORMATION HAS BEEN GONE OVER | | W/ MR BUCK AND HE IS NOW AWARE OF WHAT | | NEEDS TO BE DONE FOR THIS. | | | | 3)NOTE: PLEASE SEE RISER, AN EQUIPMENT | | GROUND NOTE SHOWS AN EQUIP GRND FROM | | TO METER, AND FROM METER TO MAIN ALSO. | | PLEASE SEE 250.6,250.24, AN EQUIP GRND | | IS ONLY INSTALLED "AFTER THE FIRST MEANS | | OF DISC". PLEASE ADJUST RISER. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2004-04-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-11 |
Time |
15:37 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-04-15 |
Time |
18:11 |
Sent To |
B |
|
Notes |
2004-04-15 00:00:00 | ********** UNSAT *************** | | | | 1)NOTE: PLEASE SEE PLANS REFERENCE | | DIFFERENT NEC CODES. 2002, 2001 AND 1999 | | WE ARE UNDER THE 2002 NEC AND ALL REF'S | | SHOULD BE TO THE 2002. | | | | 2)NOTE: PLEASE SEE NOW AN EQUIPMENT | | GROUNDING CONDUCTOR IS NOW BEING SHOWN | | FROM METER TO THE FIRST MEANS OF DISC | | ALSO. PLEASE NOTE, THE EQUIPMENT GRND | | IS ONLY INSTALLED AFTER THE FIRST MEANS | | OF DISC. PER 250.24 | | | | 3)NOTE: PLEASE SEE 220.18 FOR A MIN OF | | 5KW FOR DRYER TO BE FIGURED. | | PLEASE SEE PANEL SCHEDULE SHOWS 4.5KW, | | PLEASE ALSO SEE LOAD CALCULATIONS DO NOT | | INCLUDE DRYER. | | PLEASE SEE MICROWAVE THAT IS SHOWN ON | | LOAD CALCS IS NOT ON PANEL SCHEDULE. | | | | PLEASE VERIFY THE # OF ARC FAULT CIRCUIT | | -S SHOWN ON PANEL SCHEDULE. | | | | 4)NOTE: PLEASE SEE 210.52E FOR MISSING | | FRONT AND REAR RECEPTS OF DWELLING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-02-13 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-04-12 |
Time |
16:33 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2004-02-13 |
Time |
05:56 |
Sent To |
P |
|
Notes |
2004-02-13 00:00:00 | ******************* UNSAT ************* | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002 FOR | | ALL INFORMATION REQ'D ON A TITLE BLOCK. | | PLANS DO NOT CONTAIN TITLE BLOCK. | | PLEASE ALSO SEE FS 471 | | | | 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | RATED FOR THE AVAILABLE FAULT CURRENT. | | PER 110.9/215.5 SHOWN FOR PANEL,NOT MAIN | | | | 3)NOTE: PLEASE SEE A-4, REFERENCES 1999 | | NEC. WE ARE UNDER THE 2002. | | | | 4)NOTE: MISSING EQUIPMENT GROUNDING | | CONDUCTOR FROM MAIN TO PANEL. 250.110, | | 250.24, SIZE PER 250.122 | | | | 5)NOTE: PLEASE SEE NOTE ON RISER MENTION | | -S WEATHERHEAD TO BE 3' ABOVE ROOF. | | PLEASE SEE THAT THIS MAY CHANGE DUE TO | | ACTUAL LOCATION AND CIRCUMSTANCES OF | | ROOF. FYI. | | | | 6 )NOTE: PLEASE LIST THE REQ'D ARC | | FAULT PROTECTED CURCUIT(S) ON PANEL | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | IN BEDROOMS ARE TO BE PROTECTED , | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | | 7 )NOTE: PLEASE SEE MISSING REQ'D EGRESS | | LIGHTING AND/OR CLARIFY EGRESS LIGHTING | | PER 210.70 AND LS-101 5-8 | | MISSING AR FRONT DOOR. | | | | 8)NOTE: SMOKE DETECTORS ARE REQUIRED | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | UNIT. | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | TO FLOORS ABOVE AND IN THE VICINITY OF | | BEDROOMS. | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | A MIN OF 3' FROM BATHROOM DOORS AND | | 20' FROM COOKING APPL. | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | "PLEASE MOVE FIRST FLR CLOSER TO STAIRS" | | | | 9)NOTE: PLEASE SHOW ANY LV/ TV/ PHONE | | ON PLANS AT THIS TIME, OR PLANS WILL BE | | REQ'D TO BE SUBMITTED AT TIME OF APPLI- | | -CATION. THIS IS ONLY A NOTE AND IS NOT | | REQ'D. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2004-10-05 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-05 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-05 |
Time |
15:08 |
Sent To |
B |
|
Notes |
2004-10-05 00:00:00 | TO SH DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2004-07-12 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-12 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-12 |
Time |
13:49 |
Sent To |
B |
|
Notes |
2004-07-12 00:00:00 | TO SH DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-06-14 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-14 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-06-14 |
Time |
15:09 |
Sent To |
E |
|
Notes |
2004-06-14 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-05-11 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-11 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-11 |
Time |
15:37 |
Sent To |
E |
|
Notes |
2004-05-11 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-04-01 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-01 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-01 |
Time |
15:10 |
Sent To |
P |
|
Notes |
2004-04-01 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-03-03 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-03-03 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2004-03-03 |
Time |
14:36 |
Sent To |
B |
|
Notes |
2004-03-03 00:00:00 | TO SH DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-02-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-03 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-02 |
Time |
10:42 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2004-05-25 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-05-25 |
Time |
11:36 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2004-05-25 |
Time |
11:11 |
Sent To |
B |
|
Notes |
2004-05-25 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | REVIEW.ENERGY & MANUAL J CALCULATIONS | | INDICATE PTAC UNITS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2004-02-19 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-05-25 |
Time |
10:34 |
Rev Time |
0.33 |
Received By |
pkrauss |
Date |
2004-02-19 |
Time |
12:57 |
Sent To |
B |
|
Notes |
2004-02-19 00:00:00 | NO MECHANICAL PLANS SUBMITTED.ENERGY | | CALCULATIONS INDICATE 3 PTAC (UNDUCTED) | | UNITS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2004-06-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-10-14 |
Time |
17:04 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2004-06-28 |
Time |
14:15 |
Sent To |
|
|
Notes |
2004-07-01 00:00:00 | PASSED/PROVISO | | | | TRAP REQUIRED FOR TUB ON SANT. RISER | | DIAGRAM. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2004-05-25 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-05-25 |
Time |
10:16 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2004-05-25 |
Time |
10:16 |
Sent To |
M |
|
Notes |
2004-05-25 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1) SHT A4 SANITARY RISER DIAGRAM IS UN- | | CLEAR AND DOES NOT MEET CODE. SECTION | | 104.2.1. - REMOVE ALL INFORMATION FROM | | THE SANITARY RISER DIAGRAM THAT HAS NO | | RELEVANCE TO THE RISER. THE FLOOR JOISTS | | MAKE THE RISER DIAGRAM IMPOSSIBLE TO | | REVIEW. | | - THE WASH MACHINE SHALL CONNECT TO THE | | STACK DOWNSTREAM OF THE KITCHEN SINK. | | - THE WASH MACHINE REQUIRES A STANDPIPE | | - THE TUB REQUIRES A TRAP | | - SEE RED LINE CORRECTIONS FOR DIAGRAM | | SECTIONS: 1002.1 - 802.4 | | | | 2) THE PERSONAL SIGNATURE OF THE ARCHIT- | | ECT SHALL APPEAR ON ALL ARCHITECTURAL | | DOCUMENTS TO BE FILED FOR PUBLIC RECORD. | | INITIALS ARE NOT ACCEPTABLE. FAC 61G1-16 | | .003 & FS 481.2055. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2004-04-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-14 |
Time |
06:39 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2004-04-12 |
Time |
16:32 |
Sent To |
E |
|
Notes |
2004-04-12 00:00:00 | DENIED; | | PLUMBING RISER DIAGRAM NOT TO CODE. ASK | | YOUR PLUMBING CONTRACTOR TO DRAW ONE FOR | | YOU. | | NOTE 1 EXISTING SANITARY AND DRAIN FIELD | | TO BE REMOVED. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-02-13 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-01 |
Time |
15:11 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2004-02-13 |
Time |
12:59 |
Sent To |
M |
|
Notes |
2004-02-13 00:00:00 | DENIED; | | 1.AUTOMATIC CLOTHES WASHER REQUIRED. SEE | | FBC PLUMBING TABLE 403.2 ONE AND TWO | | FAMILY DWELLINGS. | | 2.SANITARY RISER DIAGRAM NOT TO CODE. | | KITCHEN SINK IS NOT VENTED, BATHROOM | | CANNOT BE INSTALLED AS DRAWN. | | 3.IS W/H 30 OR 50 GAL.? | | 4.H2O RISER DIAGRAM, SHOCK ARRESTORS NOT | | AIR CHAMBERSARE REQUIRED PER SEC 604.9 | | 5.PLUMBING NOTE #1. BUILDING SEWER IS | | REQUIRED TO BE INSTALLED TO THE PUBLIC | | SEWER SYSTEM. SEPIC TANK NEEDS TO BE | | REMOVED. | | 6.NOTE # 10 REMOVE NOTE HOT WATER SHOULD | | 120 DEG. ONLY COMMERCIAL DISHWASHER | | REQUIRE 180 DEG. WATER. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-05-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-04-21 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-05-03 |
Time |
11:35 |
Sent To |
B |
|
Notes |
|
|