Plan Review Details - Permit 04011355
Plan Review Stops For Permit 04011355
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-04-16 Cont ID  
Sent By lsmith Date 2004-04-16 Time 13:50 Rev Time 0.50
Received By lsmith Date 2004-04-16 Time 13:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-03-23 Cont ID  
Sent By csiegber Date 2004-04-07 Time 14:29 Rev Time 0.75
Received By lsmith Date 2004-03-23 Time 08:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-26 Cont ID  
Sent By pkrauss Date 2004-03-22 Time 13:59 Rev Time 0.00
Received By lsmith Date 2004-02-25 Time 13:06 Sent To  
Notes
2004-02-25 00:00:00BUILDING PLAN REVIEW:
  
 1. A NOTICE OF COMMENCEMENT MUST BE
 FILED AND A RECORDED COPY SUBMITTED
 BEFORE A PERMIT CAN BE RELEASED.
  
 2. SEE COMMENTS FROM OTHER REVIEWERS
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-12 Cont ID  
Sent By btrobaug Date 2004-03-12 Time 17:12 Rev Time 0.33
Received By btrobaug Date 2004-03-12 Time 17:03 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-02-09 Cont ID  
Sent By csiegber Date 2004-03-08 Time 12:43 Rev Time 0.50
Received By btrobaug Date 2004-02-09 Time 10:37 Sent To P
Notes
2004-02-09 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} NOTE THAT THE SIGNATURE OF THE EN-
 GINEER IS REQUIRED ON HIS/HER SEAL PER
 61G15-23.002 FLORIDA ADMINISTRATIVE
 CODE. INITIALS ARE NOT ACCEPTABLE PER
 F.B.P.E.
  
 2} THE INSTA HOT SHOWN ON THE PLAN IS
 NOT SHOWN IN THE LOAD CALCULATION/PANEL
 SCHEDULE. PLEASE INCLUDE SAME.
  
 3} PLEASE SEE 220.3(B)(4) FOR RECESSED
 LUMINAIRE CALCULATION.
  
 4} SEE 220.18 FOR DRYER CALCULATION
 REQUIREMENTS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-01-13 Cont ID  
Sent By ptjomsto Date 2005-01-13 Time 09:55 Rev Time 0.00
Received By ptjomsto Date 2005-01-13 Time 09:55 Sent To  
Notes
2005-01-13 00:00:00SUBMITTAL GIVEN TO KEN CONRAD

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-07 Cont ID  
Sent By csiegber Date 2004-04-07 Time 14:29 Rev Time 0.00
Received By csiegber Date 2004-04-07 Time 14:29 Sent To B
Notes
2004-04-07 00:00:00TO LS DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-08 Cont ID  
Sent By csiegber Date 2004-03-08 Time 12:43 Rev Time 0.00
Received By csiegber Date 2004-03-08 Time 12:43 Sent To E
Notes
2004-03-08 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-26 Cont ID  
Sent By mmclean Date 2004-03-08 Time 12:42 Rev Time 0.00
Received By csiegber Date 2004-01-28 Time 16:12 Sent To  
Notes
2004-02-04 00:00:001/28/04 TO Z
 2/4/04 TO E

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-22 Cont ID  
Sent By pkrauss Date 2004-03-22 Time 13:58 Rev Time 0.33
Received By pkrauss Date 2004-03-22 Time 13:57 Sent To B
Notes
2004-03-22 00:00:00PROVISO:
 1.A MINIMUM OF 4" CLEARANCE REQUIRED
 AROUND THE AHU PER 2001 FBC(M) 603.1.3.
  
 2.AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED PER 2001 FBC(M)
 307.2.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-02-11 Cont ID  
Sent By btrobaug Date 2004-03-12 Time 17:12 Rev Time 0.33
Received By pkrauss Date 2004-02-11 Time 15:37 Sent To B
Notes
2004-02-11 00:00:00DENIED:
 1.ONLY 1 SET OF ENERGY AND MANUAL J
 CALCULATIONS SUBMITTED PER 2001 FBC
 104.2.1, A MINIMUM OF 2 COPIES OF PLANS
 AND SPECIFICATIONS TO BE SUBMITTED FOR
 REVIEW.
  
 2.PLANS HAVE A COPY OF THE ENGINEERS
 SIGNATURE AND NO EMBOSSED SEAL AS
 REQUIRED BY FS 471.025 AND 61G15-23.002.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-02-09 Cont ID  
Sent By btrobaug Date 2004-02-09 Time 10:51 Rev Time 0.33
Received By kstevens Date 2004-02-09 Time 17:06 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-02-02 Cont ID  
Sent By csiegber Date 2004-01-28 Time 16:13 Rev Time 0.00
Received By mmclean Date 2004-02-02 Time 16:56 Sent To I
Notes
***NONE***