Plan Review Stops For Permit 04011355 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-04-16 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-04-16 |
Time |
13:50 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2004-04-16 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-03-23 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-07 |
Time |
14:29 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
2004-03-23 |
Time |
08:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-02-26 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-03-22 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2004-02-25 |
Time |
13:06 |
Sent To |
|
|
Notes |
2004-02-25 00:00:00 | BUILDING PLAN REVIEW: | | | | 1. A NOTICE OF COMMENCEMENT MUST BE | | FILED AND A RECORDED COPY SUBMITTED | | BEFORE A PERMIT CAN BE RELEASED. | | | | 2. SEE COMMENTS FROM OTHER REVIEWERS | | | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-03-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-03-12 |
Time |
17:12 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2004-03-12 |
Time |
17:03 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-02-09 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-03-08 |
Time |
12:43 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2004-02-09 |
Time |
10:37 |
Sent To |
P |
|
Notes |
2004-02-09 00:00:00 | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} NOTE THAT THE SIGNATURE OF THE EN- | | GINEER IS REQUIRED ON HIS/HER SEAL PER | | 61G15-23.002 FLORIDA ADMINISTRATIVE | | CODE. INITIALS ARE NOT ACCEPTABLE PER | | F.B.P.E. | | | | 2} THE INSTA HOT SHOWN ON THE PLAN IS | | NOT SHOWN IN THE LOAD CALCULATION/PANEL | | SCHEDULE. PLEASE INCLUDE SAME. | | | | 3} PLEASE SEE 220.3(B)(4) FOR RECESSED | | LUMINAIRE CALCULATION. | | | | 4} SEE 220.18 FOR DRYER CALCULATION | | REQUIREMENTS. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-01-13 |
|
|
Cont ID |
|
Sent By |
ptjomsto |
Date |
2005-01-13 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
ptjomsto |
Date |
2005-01-13 |
Time |
09:55 |
Sent To |
|
|
Notes |
2005-01-13 00:00:00 | SUBMITTAL GIVEN TO KEN CONRAD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-04-07 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-07 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-07 |
Time |
14:29 |
Sent To |
B |
|
Notes |
2004-04-07 00:00:00 | TO LS DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-03-08 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-03-08 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-03-08 |
Time |
12:43 |
Sent To |
E |
|
Notes |
2004-03-08 00:00:00 | TO BT DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-02-26 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-03-08 |
Time |
12:42 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-28 |
Time |
16:12 |
Sent To |
|
|
Notes |
2004-02-04 00:00:00 | 1/28/04 TO Z | | 2/4/04 TO E |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-03-22 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-03-22 |
Time |
13:58 |
Rev Time |
0.33 |
Received By |
pkrauss |
Date |
2004-03-22 |
Time |
13:57 |
Sent To |
B |
|
Notes |
2004-03-22 00:00:00 | PROVISO: | | 1.A MINIMUM OF 4" CLEARANCE REQUIRED | | AROUND THE AHU PER 2001 FBC(M) 603.1.3. | | | | 2.AUXILIARY DRAIN PAN WITH OVERFLOW | | PROTECTION REQUIRED PER 2001 FBC(M) | | 307.2.3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-02-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-03-12 |
Time |
17:12 |
Rev Time |
0.33 |
Received By |
pkrauss |
Date |
2004-02-11 |
Time |
15:37 |
Sent To |
B |
|
Notes |
2004-02-11 00:00:00 | DENIED: | | 1.ONLY 1 SET OF ENERGY AND MANUAL J | | CALCULATIONS SUBMITTED PER 2001 FBC | | 104.2.1, A MINIMUM OF 2 COPIES OF PLANS | | AND SPECIFICATIONS TO BE SUBMITTED FOR | | REVIEW. | | | | 2.PLANS HAVE A COPY OF THE ENGINEERS | | SIGNATURE AND NO EMBOSSED SEAL AS | | REQUIRED BY FS 471.025 AND 61G15-23.002. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-02-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-02-09 |
Time |
10:51 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-02-09 |
Time |
17:06 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-02-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-28 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-02-02 |
Time |
16:56 |
Sent To |
I |
|
Notes |
|
|