Plan Review Stops For Permit 04010955 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2004-05-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-05-14 |
Time |
16:32 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2004-05-14 |
Time |
16:32 |
Sent To |
PC |
|
Notes |
2004-05-14 00:00:00 | BUILDING REVIEW PROVISO: | | 1-REAR PORCH REVISION WAS APPROVED. | | NEED TO PROVIDE ALL INFORMATION THAT | | WAS REQUESTED ON PROVISO DATED 3/16/04 | | PRIOR TO INSTALLATION TO AVOID ANY | | DELAYS OR CONFLICTS. SEE ATTACHED | | COPY OF SUCH PROVISO. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-03-16 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-05-12 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2004-03-16 |
Time |
15:46 |
Sent To |
E |
|
Notes |
2004-03-16 00:00:00 | BUILDING REVIEW PROVISO: | | 1-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS UNDER A SEPARATE PERMIT. | | 2-PROVIDE FLORIDA OR LOCAL PRODUCT | | APPROVAL FOR: A)SINGLE HUNG WINDOWS: | | NEED DADE COUNTY DRAWINGS THAT MATCH | | FLORIDA PRODUCT APPROVAL. | | B)FIXED WINDOWS: NEED DADE COUNTY DWGS | | THAT MATCH FLORIDA PRODUCT APPROVAL. | | **NEED ARCHED & RECTANGULAR WINDOWS. | | C)CLARIFY WHICH PRODUCT APPROVAL IS FOR | | GARAGE SIDE DOOR AND WHICH ONE IS FOR | | ENTRY DOORS. | | D)PROVIDE "BENCHMARK" OR "THERMA-TRU" | | DWGS THAT MATCH FLORIDA PRODUCT APPRO- | | VAL ACCORDINGLY. | | E)NEED TO CLARIFY WHICH OPENING IS GOING | | TO BE USED FOR MEANS OF ESCAPE WHEN | | SHUTTERS ARE INSTALLED. SEC. 1005.4.5 | | FBC 2001. | | F)GARAGE DOOR PRODUCT APPROVAL IS FOR | | 110MPH WIND LOAD ZONE. WHERE ARE IN | | 140MPH ZONE. RESUBMIT AS REQUIRED. | | **NOTE: THERE ARE SOME | | G)ROOF TILE FOR 140MPH WIND LOAD. | | H)ALL STRUCTURAL CONNECTORS. | | | | 3-PROVIDE COMPLETE DETAIL AND SPECS FOR | | INSTALLATION OF SLIDING GLASS DOORS & | | TRANSOM ABOVE ASSEMBLY ATTACHED TO THE | | HORIZONTAL STRUCTURAL STEEL HEADER. | | SPECIFY ALL FASTENERS. SECTION | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | 4-NEED 7/8 MIN. STUCCO THICKNESS AT ALL | | FRAMED AREAS AS REQUIRED BY ASTM C926. | | REVISE ALL DETAILS/NOTES AS REQUIRED. | | 5-CLARIFY IF ENTRY DOOR IS GOING TO BE | | THE MEANS OF EGRESS. PRODUCT APPROVAL | | SUBMITTED IS FOR NON-IMPACT DOOR. NEED | | DOOR W/ IMPACT GLAZING OR SOLID DOOR. | | SEE NOTES ON DWG #2 AND CLARIFY. | | 6-SPECIFY ROOF TILE FASTENERS AS REQ'D | | BY SEC. 104.2.1.1 CITY AMENDMENTS TO | | FBC AND SEC. 1606.3 FBC 2001. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-03-09 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-03-12 |
Time |
16:40 |
Rev Time |
1.50 |
Received By |
jgomez |
Date |
2004-03-09 |
Time |
12:02 |
Sent To |
PC |
|
Notes |
2004-03-09 00:00:00 | BUILDING REVIEW 2ND CHECKLIST: | | 1-ITEMS ON PREVIOUS CHECKLIST DATED | | 2-13-04 WERE NOT ADDRESSED. | | SEE ATTACHED COPY OF PREVIOUS | | CHECKLIST AND PROVIDE ALL REQUIRED | | INFORMATION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT 805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-02-13 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-03-01 |
Time |
15:03 |
Rev Time |
3.00 |
Received By |
jgomez |
Date |
2004-02-13 |
Time |
17:45 |
Sent To |
PC |
|
Notes |
2004-02-13 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS OR APPLY FOR SEPARATE PERMIT. | | 2-PROVIDE FLORIDA OR LOCAL PRODUCT APPRO | | VAL FOR: A)ROOF TILE. | | B)ENTRY DOORS WITH DWGS THAT WERE SUBMI- | | TTED FOR FLORIDA PRODUCT APPROVAL. | | **NOTE: IF DOOR IS GOING TO BE USED AS | | MEANS OF ESCAPE WHEN SHUTTERS ARE UP, | | THEN NEED TO HAVE MISSILE IMPACT GLASS | | OR SOLID DOORS. | | C)SIDE SWING DOOR WITH DWGS THAT MATCH | | FLORIDA PRODUCT APPROVAL REPORT. | | D)ARCHED AND RECTANGULAR FIXED WINDOWS | | WITH DWGS THAT MATCH FLORIDA PRODUCT | | APPROVAL. | | E)SINGLE HUNG WINDOWS WITH DWGS THAT | | MATCH FLORIDA PRODUCT APPROVAL REPORT. | | F)ALL STRUCTURAL CONNECTORS. | | | | 3-PROVIDE COMPLETE DETAIL AND SPECS FOR | | CONSTRUCTION OF ARCHED OPENINGS. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | 4-PROVIDE COMPLETE DETAIL AND SPECS FOR | | INSTALLATION OF SLIDING GLASS DOORS & | | TRANSOM ABOVE ASSEMBLY JOINED BY THE | | HORIZONTAL STRUCTURAL MULLION. SPECIFY | | ALL FASTENERS. SECTION 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. | | 5-NEED 5/8" MIN. STUCCO THICKNESS AT | | WOOD FRAMED AREAS. ASTM C-926. REVISE | | ALL DETAILS/SPECS AS REQ'D. | | 6-SPECIFY WWM SUPPORTS AND SPACING IN | | CONCRETE SLAB OR SPECIFY JOINTS. | | SEC. 1909.3 FBC 2001. | | 7-SPECIFY FOOTING SIZE AND REINFORCING | | FOR F5 CONCRETE PAD. SEE FOUNDATION | | PLAN. SEC. 104.2.1.2 CITY AMENDMENTS | | 8-REVISE DETAIL 38/S1. NEED 12" MINIMUM | | BELOW GRADE. SEC. 1804.1.3 FBC 2001. | | 9-SHEET C1: UPDATE CONCRETE NOTES. SEE | | COMMENTS ON PLAN AND CHAPTER 35 FBC/01 | | 10-SHEET A-5: UPDATE GENERAL NOTES. SEE | | COMMENTS ON PLANS. | | 11-SHEET S-1: CLARIFY TYPE OF COLUMN AT | | BAY WINDOW. SEE COMMENTS ON PLAN. | | 12-SHEET S-2: A)ROOF TILE ATTACHMENT | | DIAPHRAGM IS TAKEN FROM SBC 1997.NEED | | TO UPDATE AS REQUIRED. SEE FBC 2001 | | SEC. 1606.3 AND SEC. 104.2.1.1 CITY | | AMENDMENTS TO FBC 2001. | | B)SEE COMMENTS ON PLANS. REVISE AS REQ'D | | 13-SHEET S-3: PROVIDE ONLY DETAILS THAT | | APPLY TO THIS PROJECT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT 805-6712. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-23 |
Time |
16:58 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-06-23 |
Time |
16:58 |
Sent To |
|
|
Notes |
2004-06-23 00:00:00 | ********** REDLINED PLANS ******** | | | | PLANS STILL SHOW ARC FAULT PER 99 NEC, | | THIS PERMIT IS UNDER THE 2002 NEC. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-05-05 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-06-22 |
Time |
14:06 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-05-05 |
Time |
20:16 |
Sent To |
P |
|
Notes |
2004-05-05 00:00:00 | ***** REDLINED ***** | | | | ARC FAULT PROECTION IS UNDER 2002 NEC | | 210.12. PLANS NOTES MENTION 99 NEC | | REQUIRMENTS. | | NOET #14 ALSO MENTIONS SD'S TO BE | | WIRED INTO KIT/BATH LTS. | | THIS WOULD REQ' ARC FAULT PROTECTION | | ALSO. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-03-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-03 |
Time |
14:32 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2004-03-17 |
Time |
12:10 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-01-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-03-16 |
Time |
15:46 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2004-01-26 |
Time |
12:01 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-06-21 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-21 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-06-21 |
Time |
16:27 |
Sent To |
M |
|
Notes |
2004-06-21 00:00:00 | SENT TO PK DESX/REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-05-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-03 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-03 |
Time |
14:32 |
Sent To |
E |
|
Notes |
2004-05-03 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-02-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-25 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-25 |
Time |
11:01 |
Sent To |
M |
|
Notes |
2004-02-25 00:00:00 | TO PK BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-02-13 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-01-22 |
Time |
17:05 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-21 |
Time |
14:03 |
Sent To |
|
|
Notes |
2004-01-23 00:00:00 | TO SFD RACK/E | 2004-01-21 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2004-06-22 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-06-22 |
Time |
14:06 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2004-06-22 |
Time |
14:06 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2004-05-12 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-21 |
Time |
16:27 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2004-05-12 |
Time |
09:44 |
Sent To |
B |
|
Notes |
2004-05-12 00:00:00 | DENIED: | | REVISION INDICATES CHANGE IN THE RETURN | | AIR JUMPER FROM THE MASTER SUITE.THE | | DUCT SIZE HAS NOT CHANGED.THE PROPER | | SIZE PER THE REVISED 2001 FBC(M) 601.4 | | EXCEPTION #1 & 3, THE MINIMUM SIZE FOR | | THE JUMPER SHALL BE 16" NOT 14" AS | | INDICATED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2004-03-12 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-05-08 |
Time |
12:58 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2004-03-12 |
Time |
16:39 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2004-03-01 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-03-01 |
Time |
14:59 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2004-03-01 |
Time |
14:59 |
Sent To |
B |
|
Notes |
2004-03-01 00:00:00 | DENIED: | | COMMENTS FROM PLAN REVIEW DATED 1-30-04 | | WERE NOT ADDRESSED.SEE ATTACHED FOR | | PREVIOUS COMMENTS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-01-30 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-25 |
Time |
11:01 |
Rev Time |
0.33 |
Received By |
pkrauss |
Date |
2004-01-30 |
Time |
13:55 |
Sent To |
P |
|
Notes |
2004-01-30 00:00:00 | DENIED: | | 2001 FBC(M) 601.4 EXCEPTION 1 THROUGH 3 | | | | RETURN AIR JUMPERS SHALL BE A MINIMUM | | OF 1 1/2 TIMES THE CROSS SECTIONAL AREA | | (SQ INCHES) OF THE SUPPLY DUCT SERVING | | THAT AREA.MASTER BEDROOM SHALL INCLUDE | | ALL SUPPLY AIR TO THE MASTER SUITE FOR | | THE TOTAL SUPPLY AIR TO THAT AREA. | | PLEASE SEE THE ATTACHED SCHEDULE TO | | REVISE PLANS AND RESUBMIT FOR APPROVAL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2004-05-08 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-05-08 |
Time |
12:58 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2004-05-08 |
Time |
12:58 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-03-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-05 |
Time |
20:21 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2004-03-17 |
Time |
11:39 |
Sent To |
|
|
Notes |
2004-03-17 00:00:00 | REVERSE SANT. RISER DIAGRAM - RESTAMP |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-02-03 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-01-30 |
Time |
13:55 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2004-02-03 |
Time |
15:27 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2004-03-24 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-03-24 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-03-24 |
Time |
12:39 |
Sent To |
B |
|
Notes |
2004-03-24 00:00:00 | AT JULIO'S DESK MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2004-03-17 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-03-17 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-03-17 |
Time |
10:36 |
Sent To |
B |
|
Notes |
2004-03-17 00:00:00 | DENIED, THE RESTAMP NEED TO MEET THE | | FRONT SETBACK OF 20FT FOR SIDE LOAD | | GARAGE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-01-22 |
Time |
17:05 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-01-22 |
Time |
17:05 |
Sent To |
I |
|
Notes |
|
|