Plan Review Details - Permit 04010955
Plan Review Stops For Permit 04010955
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-05-17 Cont ID  
Sent By jgomez Date 2004-05-14 Time 16:32 Rev Time 0.50
Received By jgomez Date 2004-05-14 Time 16:32 Sent To PC
Notes
2004-05-14 00:00:00BUILDING REVIEW PROVISO:
 1-REAR PORCH REVISION WAS APPROVED.
 NEED TO PROVIDE ALL INFORMATION THAT
 WAS REQUESTED ON PROVISO DATED 3/16/04
 PRIOR TO INSTALLATION TO AVOID ANY
 DELAYS OR CONFLICTS. SEE ATTACHED
 COPY OF SUCH PROVISO.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-03-16 Cont ID  
Sent By pkrauss Date 2004-05-12 Time 09:44 Rev Time 0.00
Received By jgomez Date 2004-03-16 Time 15:46 Sent To E
Notes
2004-03-16 00:00:00BUILDING REVIEW PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR: A)SINGLE HUNG WINDOWS:
 NEED DADE COUNTY DRAWINGS THAT MATCH
 FLORIDA PRODUCT APPROVAL.
 B)FIXED WINDOWS: NEED DADE COUNTY DWGS
 THAT MATCH FLORIDA PRODUCT APPROVAL.
 **NEED ARCHED & RECTANGULAR WINDOWS.
 C)CLARIFY WHICH PRODUCT APPROVAL IS FOR
 GARAGE SIDE DOOR AND WHICH ONE IS FOR
 ENTRY DOORS.
 D)PROVIDE "BENCHMARK" OR "THERMA-TRU"
 DWGS THAT MATCH FLORIDA PRODUCT APPRO-
 VAL ACCORDINGLY.
 E)NEED TO CLARIFY WHICH OPENING IS GOING
 TO BE USED FOR MEANS OF ESCAPE WHEN
 SHUTTERS ARE INSTALLED. SEC. 1005.4.5
 FBC 2001.
 F)GARAGE DOOR PRODUCT APPROVAL IS FOR
 110MPH WIND LOAD ZONE. WHERE ARE IN
 140MPH ZONE. RESUBMIT AS REQUIRED.
 **NOTE: THERE ARE SOME
 G)ROOF TILE FOR 140MPH WIND LOAD.
 H)ALL STRUCTURAL CONNECTORS.
  
 3-PROVIDE COMPLETE DETAIL AND SPECS FOR
 INSTALLATION OF SLIDING GLASS DOORS &
 TRANSOM ABOVE ASSEMBLY ATTACHED TO THE
 HORIZONTAL STRUCTURAL STEEL HEADER.
 SPECIFY ALL FASTENERS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 4-NEED 7/8 MIN. STUCCO THICKNESS AT ALL
 FRAMED AREAS AS REQUIRED BY ASTM C926.
 REVISE ALL DETAILS/NOTES AS REQUIRED.
 5-CLARIFY IF ENTRY DOOR IS GOING TO BE
 THE MEANS OF EGRESS. PRODUCT APPROVAL
 SUBMITTED IS FOR NON-IMPACT DOOR. NEED
 DOOR W/ IMPACT GLAZING OR SOLID DOOR.
 SEE NOTES ON DWG #2 AND CLARIFY.
 6-SPECIFY ROOF TILE FASTENERS AS REQ'D
 BY SEC. 104.2.1.1 CITY AMENDMENTS TO
 FBC AND SEC. 1606.3 FBC 2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-03-09 Cont ID  
Sent By pkrauss Date 2004-03-12 Time 16:40 Rev Time 1.50
Received By jgomez Date 2004-03-09 Time 12:02 Sent To PC
Notes
2004-03-09 00:00:00BUILDING REVIEW 2ND CHECKLIST:
 1-ITEMS ON PREVIOUS CHECKLIST DATED
 2-13-04 WERE NOT ADDRESSED.
 SEE ATTACHED COPY OF PREVIOUS
 CHECKLIST AND PROVIDE ALL REQUIRED
 INFORMATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-13 Cont ID  
Sent By pkrauss Date 2004-03-01 Time 15:03 Rev Time 3.00
Received By jgomez Date 2004-02-13 Time 17:45 Sent To PC
Notes
2004-02-13 00:00:00BUILDING REVIEW CHECKLIST:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS OR APPLY FOR SEPARATE PERMIT.
 2-PROVIDE FLORIDA OR LOCAL PRODUCT APPRO
 VAL FOR: A)ROOF TILE.
 B)ENTRY DOORS WITH DWGS THAT WERE SUBMI-
 TTED FOR FLORIDA PRODUCT APPROVAL.
 **NOTE: IF DOOR IS GOING TO BE USED AS
 MEANS OF ESCAPE WHEN SHUTTERS ARE UP,
 THEN NEED TO HAVE MISSILE IMPACT GLASS
 OR SOLID DOORS.
 C)SIDE SWING DOOR WITH DWGS THAT MATCH
 FLORIDA PRODUCT APPROVAL REPORT.
 D)ARCHED AND RECTANGULAR FIXED WINDOWS
 WITH DWGS THAT MATCH FLORIDA PRODUCT
 APPROVAL.
 E)SINGLE HUNG WINDOWS WITH DWGS THAT
 MATCH FLORIDA PRODUCT APPROVAL REPORT.
 F)ALL STRUCTURAL CONNECTORS.
  
 3-PROVIDE COMPLETE DETAIL AND SPECS FOR
 CONSTRUCTION OF ARCHED OPENINGS. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 4-PROVIDE COMPLETE DETAIL AND SPECS FOR
 INSTALLATION OF SLIDING GLASS DOORS &
 TRANSOM ABOVE ASSEMBLY JOINED BY THE
 HORIZONTAL STRUCTURAL MULLION. SPECIFY
 ALL FASTENERS. SECTION 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 5-NEED 5/8" MIN. STUCCO THICKNESS AT
 WOOD FRAMED AREAS. ASTM C-926. REVISE
 ALL DETAILS/SPECS AS REQ'D.
 6-SPECIFY WWM SUPPORTS AND SPACING IN
 CONCRETE SLAB OR SPECIFY JOINTS.
 SEC. 1909.3 FBC 2001.
 7-SPECIFY FOOTING SIZE AND REINFORCING
 FOR F5 CONCRETE PAD. SEE FOUNDATION
 PLAN. SEC. 104.2.1.2 CITY AMENDMENTS
 8-REVISE DETAIL 38/S1. NEED 12" MINIMUM
 BELOW GRADE. SEC. 1804.1.3 FBC 2001.
 9-SHEET C1: UPDATE CONCRETE NOTES. SEE
 COMMENTS ON PLAN AND CHAPTER 35 FBC/01
 10-SHEET A-5: UPDATE GENERAL NOTES. SEE
 COMMENTS ON PLANS.
 11-SHEET S-1: CLARIFY TYPE OF COLUMN AT
 BAY WINDOW. SEE COMMENTS ON PLAN.
 12-SHEET S-2: A)ROOF TILE ATTACHMENT
 DIAPHRAGM IS TAKEN FROM SBC 1997.NEED
 TO UPDATE AS REQUIRED. SEE FBC 2001
 SEC. 1606.3 AND SEC. 104.2.1.1 CITY
 AMENDMENTS TO FBC 2001.
 B)SEE COMMENTS ON PLANS. REVISE AS REQ'D
 13-SHEET S-3: PROVIDE ONLY DETAILS THAT
 APPLY TO THIS PROJECT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-06-23 Cont ID  
Sent By dpalmer Date 2004-06-23 Time 16:58 Rev Time 0.33
Received By dpalmer Date 2004-06-23 Time 16:58 Sent To  
Notes
2004-06-23 00:00:00********** REDLINED PLANS ********
  
 PLANS STILL SHOW ARC FAULT PER 99 NEC,
 THIS PERMIT IS UNDER THE 2002 NEC.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-05-05 Cont ID  
Sent By pkrauss Date 2004-06-22 Time 14:06 Rev Time 0.33
Received By dpalmer Date 2004-05-05 Time 20:16 Sent To P
Notes
2004-05-05 00:00:00***** REDLINED *****
  
 ARC FAULT PROECTION IS UNDER 2002 NEC
 210.12. PLANS NOTES MENTION 99 NEC
 REQUIRMENTS.
 NOET #14 ALSO MENTIONS SD'S TO BE
 WIRED INTO KIT/BATH LTS.
 THIS WOULD REQ' ARC FAULT PROTECTION
 ALSO.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-17 Cont ID  
Sent By csiegber Date 2004-05-03 Time 14:32 Rev Time 0.50
Received By btrobaug Date 2004-03-17 Time 12:10 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-26 Cont ID  
Sent By jgomez Date 2004-03-16 Time 15:46 Rev Time 0.50
Received By btrobaug Date 2004-01-26 Time 12:01 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-06-21 Cont ID  
Sent By mjacobs Date 2004-06-21 Time 16:27 Rev Time 0.00
Received By mjacobs Date 2004-06-21 Time 16:27 Sent To M
Notes
2004-06-21 00:00:00SENT TO PK DESX/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-05-03 Cont ID  
Sent By csiegber Date 2004-05-03 Time 14:32 Rev Time 0.00
Received By csiegber Date 2004-05-03 Time 14:32 Sent To E
Notes
2004-05-03 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-02-25 Cont ID  
Sent By csiegber Date 2004-02-25 Time 11:01 Rev Time 0.00
Received By csiegber Date 2004-02-25 Time 11:01 Sent To M
Notes
2004-02-25 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-13 Cont ID  
Sent By mmclean Date 2004-01-22 Time 17:05 Rev Time 0.00
Received By csiegber Date 2004-01-21 Time 14:03 Sent To  
Notes
2004-01-23 00:00:00TO SFD RACK/E
2004-01-21 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2004-06-22 Cont ID  
Sent By pkrauss Date 2004-06-22 Time 14:06 Rev Time 0.25
Received By pkrauss Date 2004-06-22 Time 14:06 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2004-05-12 Cont ID  
Sent By mjacobs Date 2004-06-21 Time 16:27 Rev Time 0.35
Received By pkrauss Date 2004-05-12 Time 09:44 Sent To B
Notes
2004-05-12 00:00:00DENIED:
 REVISION INDICATES CHANGE IN THE RETURN
 AIR JUMPER FROM THE MASTER SUITE.THE
 DUCT SIZE HAS NOT CHANGED.THE PROPER
 SIZE PER THE REVISED 2001 FBC(M) 601.4
 EXCEPTION #1 & 3, THE MINIMUM SIZE FOR
 THE JUMPER SHALL BE 16" NOT 14" AS
 INDICATED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-03-12 Cont ID  
Sent By jleech Date 2004-05-08 Time 12:58 Rev Time 0.25
Received By pkrauss Date 2004-03-12 Time 16:39 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2004-03-01 Cont ID  
Sent By pkrauss Date 2004-03-01 Time 14:59 Rev Time 0.20
Received By pkrauss Date 2004-03-01 Time 14:59 Sent To B
Notes
2004-03-01 00:00:00DENIED:
 COMMENTS FROM PLAN REVIEW DATED 1-30-04
 WERE NOT ADDRESSED.SEE ATTACHED FOR
 PREVIOUS COMMENTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-01-30 Cont ID  
Sent By csiegber Date 2004-02-25 Time 11:01 Rev Time 0.33
Received By pkrauss Date 2004-01-30 Time 13:55 Sent To P
Notes
2004-01-30 00:00:00DENIED:
 2001 FBC(M) 601.4 EXCEPTION 1 THROUGH 3
  
 RETURN AIR JUMPERS SHALL BE A MINIMUM
 OF 1 1/2 TIMES THE CROSS SECTIONAL AREA
 (SQ INCHES) OF THE SUPPLY DUCT SERVING
 THAT AREA.MASTER BEDROOM SHALL INCLUDE
 ALL SUPPLY AIR TO THE MASTER SUITE FOR
 THE TOTAL SUPPLY AIR TO THAT AREA.
 PLEASE SEE THE ATTACHED SCHEDULE TO
 REVISE PLANS AND RESUBMIT FOR APPROVAL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-05-08 Cont ID  
Sent By jleech Date 2004-05-08 Time 12:58 Rev Time 0.33
Received By jleech Date 2004-05-08 Time 12:58 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-03-17 Cont ID  
Sent By dpalmer Date 2004-05-05 Time 20:21 Rev Time 0.25
Received By kstevens Date 2004-03-17 Time 11:39 Sent To  
Notes
2004-03-17 00:00:00REVERSE SANT. RISER DIAGRAM - RESTAMP

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-02-03 Cont ID  
Sent By pkrauss Date 2004-01-30 Time 13:55 Rev Time 0.25
Received By jleech Date 2004-02-03 Time 15:27 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2004-03-24 Cont ID  
Sent By mmclean Date 2004-03-24 Time 12:39 Rev Time 0.00
Received By mmclean Date 2004-03-24 Time 12:39 Sent To B
Notes
2004-03-24 00:00:00AT JULIO'S DESK MM

Review Stop Z ZONING
Rev No 2 Status F Date 2004-03-17 Cont ID  
Sent By mmclean Date 2004-03-17 Time 10:36 Rev Time 0.00
Received By mmclean Date 2004-03-17 Time 10:36 Sent To B
Notes
2004-03-17 00:00:00DENIED, THE RESTAMP NEED TO MEET THE
 FRONT SETBACK OF 20FT FOR SIDE LOAD
 GARAGE.

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-22 Cont ID  
Sent By mmclean Date 2004-01-22 Time 17:05 Rev Time 0.00
Received By mmclean Date 2004-01-22 Time 17:05 Sent To I
Notes
***NONE***