Plan Review Details - Permit 04010651
Plan Review Stops For Permit 04010651
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-04-09 Cont ID  
Sent By rbrown Date 2004-04-09 Time 09:48 Rev Time 0.00
Received By rbrown Date 2004-04-09 Time 09:48 Sent To  
Notes
2004-04-09 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 4/9/04:
  
 A) FBC 1606.1.7SHEET 8,WIND LOAD.
 THIS COMMENT HAS NOT BEEN ADDRESSED, FOR
 A SECOND TIME (SEE COMMENT C BELOW FOR
 STATE STATUTE FEE TO BE CHARGED IF THIS
 COMMENT IS NOT ADDRESS BEFORE THE NEXT
 REVIEW).FBC 104.2.1 STATES THAT THE
 CODE SHALL NOT BE CITED AS A WHOLE OR IN
 PART.LIGHT POLE NOTE 1 SHALL NOT
 SIMPLY CITE THE CODE, IT SHALL STATE THE
 BASIC WIND SPEED, WIND IMPORTANCE FACTOR
 AND WIND EXPOSURE CATEGORY.AMEND THE
 PLAN.
  
 B) 61G15-23.002(2)FL. ADMIN. CODE
 THIS COMMENT HAS NOT BEEN PROPERLY
 ADDRESSED.THE ENGINEER SHALL PRINT HIS
 NAME AND LICENSE NUMBER ON EACH SHEET
 EVEN WHEN PRACTICING THROUGH AN
 ENGINEERING BUSINESS.
  
 C) NOTE:
 CHAPTER 553.80(2)(B) FLORIDA STATUTES
 STATES THAT A LOCAL GOVERNMENT SHALL
 IMPOSE A FEE OF FOUR TIMES THE FEE FOR
 PLAN REVIEW, IF PLANS ARE REJECTED THREE
 OR MORE TIMES FOR REPEATED FAILURE TO
 CORRECT A CODE VIOLATION.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-02-27 Cont ID  
Sent By btrobaug Date 2004-04-02 Time 11:38 Rev Time 0.00
Received By rbrown Date 2004-02-27 Time 09:06 Sent To  
Notes
2004-02-27 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 STRUCTURAL SUBMITTAL ON 2-20-04 FOR
 LIGHTING POLE EMBEDMENT CALCULATIONS.
  
 A) THE SCOPE OF PERMIT# 04010651 WAS
 REDUCED TO INCLUDE 'CONDUIT ONLY'.THIS
 WAS AGREED WITH C.R. DUNN. TO ALLOW WORK
 TO COMMENCE EVENTHOUGH THE SUBMITTED
 LIGHTING POLE STRUCTURAL DETAILS WERE
 NOT VALID.THOSE STRUCTURAL DETAILS
 WERE OMITTED FROM THE PERMIT APPROVED
 SET OF PLANS BY REMOVAL OF SHEET 8 OF 11
 PRIOR TO PERMITTING.THE CURRENT
 SUBMITTAL OF EMBEDMENT DETAILS MUST BE
 SUBMITTED AS A REVISION TO THIS PERMIT
 (WITH APPROPRIATE FEE) OR AS A SEPARATE
 PERMIT APPLICATION AND SHALL INCLUDE A
 A PLAN, WITH SEAL ETC PER COMMENT (B)
 BELOW, THAT PROVIDES ALL OF THE
 INFORMATION REQUIRED TO ADDRESS COMMENT
 #1 FROM THE 1/20/04 PLAN REVIEW (COPY
 ATTACHED).
  
 B) 61G15-23.002(2)FL. ADMIN. CODE.
 IT IS NOTED THAT THE EMBEDMENT
 CALCULATION COVER SHEET INCLUDES THE
 ENGINEER'S SIGNATURE, SEAL, LICENSE #
 AND COMPANY ADDRESS AND CERTIFICATE OF
 AUTHORIZATION #.TO ADDRESS COMMENT #2
 FROM THE 1/20/04 PLAN REVIEW, THAT INFO
 SHALL ALSO BE ON THE STRUCTURAL PLAN
 REFERENCED IN COMMENT (A) ABOVE.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2004-01-26 Cont ID  
Sent By rbrown Date 2004-01-20 Time 16:42 Rev Time 0.00
Received By rbrown Date 2004-01-20 Time 16:42 Sent To  
Notes
2004-01-26 00:00:00SCOPE OF PERMIT HAS BEEN CHANGED. PERMIT
 IS NOW FOR CONDUIT ONLY.
2004-01-20 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) FBC 1606.1.7SHEET 8, WIND LOAD.
 LIGHT POLE NOTE 1 DOES REFERENCE FLORIDA
 BUILDING CODE BUT THE PLANS SHALL NOT
 SIMPLY CITE THE CODE. THE NOTES ON SHT 8
 SHALL STATE THE BASIC WIND SPEED, WIND
 IMPORTANCE FACTOR AND WIND EXPOSURE
 CATEGORY.AMEND THE PLAN.
  
 2) 61G15-23.002(2)FL. ADMIN. CODE.
 PLANS SIGNED & SEALED BY A PROFESSIONAL
 ENGINEER SHALL INCLUDE THE PRINTED NAME
 AND LICENSE NUMBER OF THE ENGINEER.
 (471.025 F.S. AND 471.023 F.S.).
 AMEND THE PLAN.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-04-22 Cont ID  
Sent By dpalmer Date 2004-04-22 Time 10:31 Rev Time 0.33
Received By dpalmer Date 2004-04-22 Time 10:30 Sent To  
Notes
2004-04-22 00:00:00REDLINED ENGINEER'S NAME AND LICENSE #

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2004-04-02 Cont ID  
Sent By csiegber Date 2004-04-14 Time 11:11 Rev Time 0.25
Received By btrobaug Date 2004-04-02 Time 11:38 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-16 Cont ID  
Sent By csiegber Date 2004-04-02 Time 10:14 Rev Time 0.75
Received By btrobaug Date 2004-01-16 Time 13:50 Sent To B
Notes
2004-01-23 00:00:00TO ROBERT BROWN,S DESK FOR APPROVAL TO
 REMOVE SHEET 8-11 THAT IS NONCOMPLIANT
 FOR WIND RESISTANCE.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-14 Time 11:11 Rev Time 0.00
Received By csiegber Date 2004-04-14 Time 11:11 Sent To E
Notes
2004-04-14 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-02 Cont ID  
Sent By csiegber Date 2004-04-02 Time 10:14 Rev Time 0.00
Received By csiegber Date 2004-04-02 Time 10:14 Sent To E
Notes
2004-04-02 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-20 Cont ID  
Sent By csiegber Date 2004-02-20 Time 11:28 Rev Time 0.00
Received By csiegber Date 2004-02-20 Time 11:28 Sent To E
Notes
2004-02-20 00:00:00TO BT DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-21 Cont ID  
Sent By csiegber Date 2004-01-21 Time 09:47 Rev Time 0.00
Received By csiegber Date 2004-01-21 Time 09:47 Sent To E
Notes
2004-01-21 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-14 Cont ID  
Sent By csiegber Date 2004-01-14 Time 16:33 Rev Time 0.00
Received By csiegber Date 2004-01-14 Time 16:33 Sent To E
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved