Plan Review Details - Permit 04010269
Plan Review Stops For Permit 04010269
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-02-27 Cont ID  
Sent By jwitmer Date 2004-02-27 Time 14:23 Rev Time 2.00
Received By jwitmer Date 2004-02-27 Time 14:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-12 Cont ID  
Sent By btrobaug Date 2004-02-20 Time 15:35 Rev Time 2.22
Received By jwitmer Date 2004-02-12 Time 07:26 Sent To  
Notes
2004-02-12 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04010269
 ADD: 10775 LA STRADA
 CONT: A R CUSTOM HOMES INC
 TEL: (561)718-4176
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL I
 S NOT DEFINITEY KNOWN, OR IS IN QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL P
 ROPERLY LICENSED IN THE STATE OF
 FLORIDA. SOILSREPORT NOT AN ORIGINAL
 SEAL.PLANS SPECIFICATIONS REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 3) PROVIDE 2 CURRENT COPIES OF SIGNED &
 SEALED SURVEYS WITH PROPOSED IMPROVEMENT
 TO BE COMPLETED.
  
 4) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG FOR
 MORE INFORMATION.
 THIS APPROVAL SYSTEM IS ALSO REQUIRED
 FOR STRAPS, BUCKETS, AS WELL AS WINDOWS,
 DOORS, SHUTTERS, ETC...
  
 5)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 THE TRUSS ANCHOR SCHEDULE IS UNREADABLE!
 PLEASE STREACH THE LETTERING OUT SO IT
 DOESN'T OVERLAP!
  
 6) STORM SHUTTERS REPORT MISSING THE
 INSTALLATION INSTRUCTIONS SEE LIMITA-
 TIONS 9.1/9.2.
 FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 7) SUBMIT GARGE INSTALLATION SCHEDULE
 FOR THE DOOR TO BE USED. THIS WILL DES-
 IGNATE PRESSURE ZONES.
  
 8)905.2.1 APPROVED SINGLE-STATION OR
 MULTIPLE STATION SMOKE DETECTORS SHALL
 BE INSTALLED IN ACCORDANCE WITH NFPA 72,
 CHAPTER 2, WITHIN EVERY DWELLING UNIT
 WITHIN AN APARTMENT HOUSE, CONDOMINIMUM,
 OR TOWNHOUSE AND EVERY GUEST OR SLEEPING
 ROOM IN A MOTEL, HOTEL, OR DORMITORY &
 SLEEPING ROOMS IN RESIDENTIAL CARE/
 ASSISTED LIVING OCCUPANCIES. WHERE MORE
 THAN ONE DETECTOR IS REQUIRED TO BE
 INSTALLED WITHIN INDIVIDUAL DWELLING
 UNIT, THE DETECTOR SHALL BE WIRED IN
 SUCH A MANNER THAT THE ACTUATION OF ONE
 ALARM WILL ACTIVATE ALL THE ALARMS IN
 THE INDIVIDUAL UNIT.
 THE SMOKE ALARMS LOCATED IN THE HALL-
 WAY RARE TO BE LOCATED NOT LESS THAN
 5'-0" AWAY FROM THE RETURN AIR, SEE
 MANUFACTURER'S SPEC.
  
 9) FL BLD CODE 2309.6 ATTIC ACCESS, PRO-
 VIDE ATTIC ACCESS 20"X36". INDICATE ON
 PLAN THE MINIMUM SIZE.
  
 10)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-02-20 Cont ID  
Sent By btrobaug Date 2004-02-20 Time 15:35 Rev Time 1.00
Received By btrobaug Date 2004-02-20 Time 14:42 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-01-22 Cont ID  
Sent By csiegber Date 2004-02-19 Time 13:25 Rev Time 0.50
Received By btrobaug Date 2004-01-22 Time 07:15 Sent To M
Notes
2004-01-22 00:00:00 
 UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE 1/0 FEEDER FROM THE METER TO THE
 PANEL IS NOT SUFFICIENT FOR 200 AMPS.SEE
 310.15(B).
  
 2} THERE ARE FOUR SMALL APPLIANCE
 CIRCUITS SHOWN ON THE LOAD CALCS
 (6000/1500=4),BUT ONLY THREE ON THE
 PANEL SCHEDULE, PLEASE CORRELATE.
  
 3} THE DINING ROOM & MORNING ROOM WIRE
 SIZE MUST BE #12 PER 210.52(B)(1).SEE
 PANEL SCHEDULE.
  
 4} THE WATER HEATER AND DRYER LOADS IN
 THE CALCULATION DOES NOT CORRESPOND
 WITH THE PANEL SCHEDULE.PLEASE
 CORRELATE.
  
 5} BATH #2 IS MISSING A RECEPTACLE,SEE
 210.52(D).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-19 Cont ID  
Sent By csiegber Date 2004-02-19 Time 13:25 Rev Time 0.00
Received By csiegber Date 2004-02-19 Time 13:25 Sent To E
Notes
2004-02-19 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-02-18 Cont ID  
Sent By mmclean Date 2004-02-19 Time 10:30 Rev Time 0.00
Received By csiegber Date 2004-02-18 Time 10:40 Sent To Z
Notes
2004-02-18 00:00:00TO MM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-12 Cont ID  
Sent By mmclean Date 2004-01-08 Time 15:36 Rev Time 0.00
Received By csiegber Date 2004-01-07 Time 14:42 Sent To  
Notes
2004-01-08 00:00:00TO SFD RACK/E
2004-01-07 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-01-29 Cont ID  
Sent By btrobaug Date 2004-01-22 Time 08:29 Rev Time 0.50
Received By hmoser Date 2004-01-29 Time 17:13 Sent To P
Notes
2004-01-29 00:00:00PASS PRIVISO MARKED ON PLAN
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-02-03 Cont ID  
Sent By hmoser Date 2004-01-29 Time 17:13 Rev Time 0.25
Received By jleech Date 2004-02-03 Time 09:51 Sent To B
Notes
2004-02-03 00:00:00NO RISER DIAGRAM. NO PLUMBING PLAN
 REVIEW.

Review Stop Z ZONING
Rev No 2 Status P Date 2004-02-19 Cont ID  
Sent By mmclean Date 2004-02-19 Time 10:30 Rev Time 0.00
Received By mmclean Date 2004-02-19 Time 10:30 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-01-08 Cont ID  
Sent By csiegber Date 2004-02-18 Time 10:40 Rev Time 0.00
Received By mmclean Date 2004-01-08 Time 15:36 Sent To I
Notes
2004-01-08 00:00:00DENIED, NEED SETBACKS FOR SITE PLAN
 CALLED CONTR