Plan Review Details - Permit 04010177
Plan Review Stops For Permit 04010177
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-01-27 Cont ID  
Sent By btrobaug Date 2004-02-26 Time 07:33 Rev Time 1.50
Received By alange Date 2004-01-27 Time 08:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-07-28 Cont ID  
Sent By btrobaug Date 2004-07-28 Time 10:20 Rev Time 0.50
Received By btrobaug Date 2004-07-28 Time 07:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-02-26 Cont ID  
Sent By csiegber Date 2004-07-27 Time 14:55 Rev Time 0.50
Received By btrobaug Date 2004-02-26 Time 07:33 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-01-12 Cont ID  
Sent By btrobaug Date 2004-02-24 Time 16:37 Rev Time 0.50
Received By btrobaug Date 2004-01-12 Time 10:11 Sent To P
Notes
2004-01-12 00:00:00 
 UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 1} PLEASE PROVIDE A LOAD CALCULATION
 INCLUDING EXISTING AND ALL ADDED LOADS
 PER 215.5.
  
 2} PROVIDE A RISER DIAGRAM INDICATING
 FEEDER TO NEW PANEL,AND GROUNDING PER
 250.32.
  
 3} SHOW LOCATION OF NEW PANEL ON PLAN.
  
 4} BATH RECEPTACLE MUST BE GFI PER
 210.8(A)(1).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-07-27 Cont ID  
Sent By csiegber Date 2004-07-27 Time 14:55 Rev Time 0.00
Received By csiegber Date 2004-07-27 Time 14:55 Sent To E
Notes
2004-07-27 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-04-02 Cont ID  
Sent By csiegber Date 2004-04-02 Time 12:17 Rev Time 0.00
Received By csiegber Date 2004-04-02 Time 12:17 Sent To P
Notes
2004-04-02 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-24 Cont ID  
Sent By btrobaug Date 2004-02-24 Time 16:37 Rev Time 0.00
Received By btrobaug Date 2004-02-24 Time 16:37 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-09 Cont ID  
Sent By csiegber Date 2004-01-09 Time 09:23 Rev Time 0.00
Received By csiegber Date 2004-01-09 Time 09:23 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-07 Cont ID  
Sent By mmclean Date 2004-01-08 Time 15:48 Rev Time 0.00
Received By csiegber Date 2004-01-07 Time 09:15 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-01-21 Cont ID  
Sent By kstevens Date 2004-01-15 Time 12:14 Rev Time 0.30
Received By pkrauss Date 2004-01-21 Time 11:04 Sent To B
Notes
2004-01-21 00:00:00NO MECHANICAL PLANS OR WORK SUBMITTED
 WITH PERMIT APPLICATION.
  
 PLEASE NOTE, PLAN SHEET A-2 INDICATES A
 GRILLE, WASHER AND DRYER.DRYER EXHAUST
 SHALL COMPLY WITH 2001 FBC(M) 504.4.
 PLEASE PROVIDE ADDITIONAL INFORMATION
 ON THE GRILLE (IS IT GAS ELECTRIC INDOOR
 OR OUTDOOR USE).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-04-09 Cont ID  
Sent By kstevens Date 2004-04-09 Time 18:27 Rev Time 1.00
Received By kstevens Date 2004-04-09 Time 18:27 Sent To  
Notes
2004-04-09 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SOWER COMPARTMENT REQUIRED PER SECT-
 IONS 417, 417.1, 417.4, 417. 417.5,
 417.5.2.
 2) MORE INFORMATION REQUIRED FOR SHOWER.
 EXPLAIN HOW SPRAY FROM SHOWER HEAD WILL
 BE CONTAINED IN SHOWER.
 3) TRAP NOT SHOWN FOR BAR SINK. SECTION
 1002.1
 4) FLOOR DRAIN DOWNSTREAM OF WASH MACH-
 INE IS NOT VENTED.
 5 A PROFESSIONAL ENGINEER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS,
 SPECIFICATIONS, REPORTS AND FINAL BID
 DOCUMENTS PROVIDED TO THE OWNER OR THE
 OWNER'S REPRESENTATIVE, OR OTHER DOCU-
 MENTS PREPARED OR ISSUED BY SAID REGIS-
 TRANT AND BEING FILED FOR PUBLIC RECORD.
 THE DATE THAT THE SIGNATURE AND SEAL IS
 AFFIXED AS PROVIDED HEREIN SHALL BE EN-
 TERED ON SAID PLANS, SPECIFICATIONS, RE-
 PORTS, OR OTHER DOCUMENTS IMMEDIATELY
 UNDER THE SIGNATURE OF THE PROFESSIONAL
 ENGINEER, FAC 61G15-23.002(1) FS 471.025
 INITIALS ARE NOT ACCEPTABLE. FULL SIGNA-
 TURE REQUIRED PER FBPE
 EACH SHEET OF PLANS AND PRINTS WHICH
 MUST BE SEALED UNDER THE PROVISIONS OF
 CHAPTER 471 SHALL BE SEALED, SIGNED AND
 DATED BY THE PROFESSIONAL ENGINEER IN
 RESPONSIBLE CHARGE. FAC 61G15-23.002(2)
 FS 471.025
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-01-15 Cont ID  
Sent By csiegber Date 2004-04-02 Time 12:17 Rev Time 0.33
Received By kstevens Date 2004-01-15 Time 12:00 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-08 Cont ID  
Sent By csiegber Date 2004-01-07 Time 09:15 Rev Time 0.00
Received By mmclean Date 2004-01-08 Time 15:47 Sent To I
Notes
***NONE***