Plan Review Stops For Permit 04010107 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2004-06-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-06-22 |
Time |
14:32 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2004-06-22 |
Time |
14:32 |
Sent To |
PC |
|
Notes |
2004-06-22 00:00:00 | PRODUCT APPROVAL SUBMITTAL CHECKLIST: | | 1-PROVIDE DRAWINGS FOR GARAGE DOORS | | THAT MATCH THOSED DRAWINGS SUBMITTED | | FOR SBCCI APPROVAL. NEED DWGS THAT | | WERE SIGNED AND SEALED ON SAME DATE | | AS NOTED ON SBCCI EVALUATION REPORT. | | 2-PROVIDE FLORIDA PRODUCT APPROVAL COVER | | PAGE FOR ENTRY DOOR THAT MATCHES DADE | | COUNTY NOA SUBMITTED. BENCHMARK AND | | THERMA-TRU ARE 2 DIFFERENT MODELS. | | 3-SIMONTON WINDOWS AND DOORS PACKAGE IS | | INCOMPLETE. MISSING FLORIDA PRODUCT | | APPROVAL COVER PAGE FOR FIXED WINDOWS | | AND SLIDING GLASS DOORS INSTALLED ON | | THIS PROJECT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT 805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-03-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-03-19 |
Time |
07:42 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2004-03-19 |
Time |
07:42 |
Sent To |
PC |
|
Notes |
2004-03-19 00:00:00 | ENGINEER LETTER FOR CLARIFICATION OF | | ITEMS REQUESTED ON PROVISO DATED 2-6-04. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-02-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:11 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2004-02-06 |
Time |
19:22 |
Sent To |
PC |
|
Notes |
2004-02-06 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-PROVIDE COMPLETE CURRENT PRODUCT APPRO | | VAL FOR ALL DOORS, WINDOWS, MULLIONS, | | GLASS BLOCK, ROOF TILE AND ALL | | STRUCTURAL CONNECTORS UNDER A SEPARATE | | PERMIT AS REQ'D BY THE BLDG OFFICIAL. | | 2-DETAIL E/4 AND RESIDENTIAL NOTES ON | | DWG #2 DON'T MATCH. REVISE AS REQUIRED | | 3-CLARIFY/REVISE TRUSS ANCHOR SCHEDULE. | | 4-TYPICAL WALL SEC. DETAIL A/4:CLARIFY | | WHERE ARE TABLES 6 AND 8 FOR ROOF TILE | | FASTENERS TAKEN FROM. SEE SEC. 1606.3 | | FBC 2001 AND SEC. 104.2.1.1 CITY | | AMENDMENTS TO FBC 2001. | | 5-SHEET #7:A)REVISE THE DESIGN PRESSURES | | FOR OPENINGS. | | B)WINDOWS SHOWN ON ELEVATION DON'T MATCH | | THE WINDOW SCHEDULE. | | C)REVISE ALL NOTES ON FLOOR PLAN & ROOF | | FRAMING PLAN TO REFLECT CHANGE OF WOOD | | BEAM TO CONCRETE BEAM. | | 6-SHEET #3: CLARIFY NOTE REGARDING THE | | UPLIFT CALCS AND CONNECTORS SPECIFIED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-01-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-01-09 |
Time |
06:08 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-01-09 |
Time |
06:03 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-27 |
Time |
12:11 |
Sent To |
B |
|
Notes |
2004-02-27 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-02-11 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-11 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-11 |
Time |
16:09 |
Sent To |
B |
|
Notes |
2004-02-11 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-02-06 |
Time |
19:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2004-01-06 |
Time |
13:41 |
Sent To |
PC |
|
Notes |
2004-01-20 00:00:00 | TO KS BOX | 2004-01-06 00:00:00 | TO Z | | TO E/DP |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-01-09 |
Time |
06:08 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2004-01-22 |
Time |
15:21 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-01-22 |
Time |
15:27 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-01-22 |
Time |
15:27 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-01-06 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-01-06 |
Time |
12:26 |
Sent To |
I |
|
Notes |
|
|