Plan Review Details - Permit 04010091
Plan Review Stops For Permit 04010091
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-06-23 Cont ID  
Sent By jgomez Date 2004-06-23 Time 14:09 Rev Time 0.50
Received By jgomez Date 2004-06-23 Time 14:09 Sent To PC
Notes
2004-06-23 00:00:00PRODUCT APPROVAL SUBMITTAL CHECKLIST:
 1-PROVIDE COPIES OF GARAGE DOOR DRAWINGS
 SUBMITTED TO SBCCI FOR APPROVAL. NEED
 DRAWINGS SIGNED AND SEALED ON THE DATE
 NOTED ON SBCCI EVALUATION REPORT.
 2-PROVIDE FLORIDA PRODUCT APPROVAL COVER
 PAGE FOR ENTRY DOOR THAT MATCHES DADE
 COUNTY NOA SUBMITTED. BENCHMARK AND
 THERMA-TRU ARE TWO DIFFERENT DOOR
 MODELS.
 3-SIMONTON DOORS/WINDOWS PACKAGE IS
 INCOMPLETE. NEED FLORIDA PRODUCT
 APPROVAL COVER PAGE FOR FIXED WINDOWS
 AND SLIDING GLASS DOORS USED.
 4-PROVIDE DADE COUNTY NOA SUBMITTAL FOR
 PGT WINDOW MULLIONS THAT MATCH NOA
 NUMBER NOTED ON FLORIDA PRODUCT
 APPROVAL COVER PAGE.
 5-PROVIDE ALL INFORMATION REQUESTED ON
 PREVIOUS PROVISO. SEE ATTACHED COPY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-01-28 Cont ID  
Sent By csiegber Date 2004-02-27 Time 12:27 Rev Time 2.00
Received By jgomez Date 2004-01-28 Time 16:52 Sent To PC
Notes
2004-01-28 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-SOME DRAWINGS ARE MISSING ALL THE
 INFORMATION REQUIRED BY THE ARCHITECT
 WHEN SUBMITTING PLANS FOR PUBLIC
 RECORDS. CHAPTER 481 FLORIDA STATUTES.
 2-PROVIDE COMPLETE FLORIDA/SITE SPECIFIC
 PRODUCT APPROVAL FOR ALL DOORS,WINDOWS
 GLASS BLOCK, ROOF TILE, MULLIONS AND
 STRUCTURAL CONNECTORS.
 3-DETAIL E/4 AND RESIDENTIAL NOTES ON
 DWG #2 DON'T MATCH. REVISE AS REQ'D.
 4-REVISE WINDOW BUCK DETAIL ON SHEET #4.
 SEE SECTION 1707.4.4.2 FBC 2001 FOR
 PROPER BUCK INSTALLATION.
 5-DWG #2:A)CLARIFY/REVISE TRUSS ANCHOR
 SCHEDULE. CHECK FOR TYPOS THAT CREATE
 SOME CONFUSION ON ANCHOR SPECS.
 B)NOTE BELOW TRUSS ANCHOR SCHEDULE CALLS
 FOR ENGINEER'S DETAILS AND CALCS FOR
 HOLD DOWN ANCHORS. WHERE ARE THEY.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
  
 6-SPECIFY ROOF TILE FASTENER AS REQ'D
 BY SEC. 104.2.1.1 CITY AMENDMENTS TO
 FBC 2001. ALSO, SEE SEC. 1606.3 FBC.
 7-CLARIFY/REVISE DESIGN PRESSURES FOR
 EXTERIOR OPENINGS. EG: CHECK WINDOW AT
 BEDROOMS #2 & #3 ACCORDING TO LOCATION
 AND SIZE OF WINDOW. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 8-PROVIDE ENGINEERING CALCS FOR SIMPSON
 EG7 CONNECTOR SINCE FASTENERS ARE NOT
 THE SAME AS TESTED AND PUBLISHED BY
 SIMPSON TO COMPLY WITH SEC. 1609.4.3
 FBC 2001.
 9-PROVIDE COMPLETE SPECS FOR (4)2X12 WD
 BEAM AT REAR PORCH. HOW IS IT NAILED
 TOGETHER, ETC.SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 10-SHEET 3#: CLARIFY NOTE: "UPLIFT FOR
 EACH TRUSS ARE MORE THAN THE MAXIMUM
 VALUE SHOWN FOR THE CONNECTOR SELECTED

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-09 Cont ID  
Sent By dpalmer Date 2004-01-09 Time 11:08 Rev Time 0.33
Received By dpalmer Date 2004-01-09 Time 11:08 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-27 Cont ID  
Sent By csiegber Date 2004-02-27 Time 12:27 Rev Time 0.00
Received By csiegber Date 2004-02-27 Time 12:27 Sent To B
Notes
2004-02-27 00:00:00TO JG DESK/SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-02-05 Cont ID  
Sent By csiegber Date 2004-02-05 Time 10:21 Rev Time 0.00
Received By csiegber Date 2004-02-05 Time 10:21 Sent To P
Notes
2004-02-05 00:00:00TO GAS

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-28 Cont ID  
Sent By mmclean Date 2004-01-06 Time 12:51 Rev Time 0.00
Received By jgomez Date 2004-01-06 Time 12:18 Sent To PC
Notes
2004-01-20 00:00:00TO JG DESK/RESUB
2004-01-06 00:00:00TO Z
 TO E/DP

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-01-14 Cont ID  
Sent By dpalmer Date 2004-01-09 Time 11:18 Rev Time 0.33
Received By pkrauss Date 2004-01-14 Time 14:47 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-01-16 Cont ID  
Sent By csiegber Date 2004-02-05 Time 10:21 Rev Time 0.33
Received By kstevens Date 2004-01-16 Time 10:37 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-06 Cont ID  
Sent By mmclean Date 2004-01-06 Time 12:51 Rev Time 0.00
Received By mmclean Date 2004-01-06 Time 12:51 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy