Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-06-23 Cont ID  
Sent By jgomez Date 2004-06-23 Time 12:18 Rev Time 0.50
Received By jgomez Date 2004-06-23 Time 12:18 Sent To PC
Notes
2004-06-23 00:00:00PRODUCT APPROVAL SUBMITTAL CHECKLIST:
 1-PROVIDE COPIES OF GARAGE DOOR DRAWINGS
 SUBMITTED TO SBCCI FOR APPROVAL. NEED
 DRAWINGS SIGNED AND SEALED ON THE DATE
 AS NOTED ON SBCCI EVALUATION REPORT.
 2-PROVIDE FLORIDA PRODUCT APPROVAL COVER
 PAGE FOR ENTRY DOOR THAT MATCHES DADE
 COUNTY NOA SUBMITTED. BENCHMARK AND
 THERMA-TRU ARE 2 DIFFEENT DOOR MODELS.
 3-SIMONTON WINDOWS/DOORS PACKAGE IS
 INCOMPLETE NEED FLORIDA PRODUCT
 APPROVAL COVER PAGE FOR FIXED WINDOWS
 AND SLIDING GLASS DOORS USED.
 4-PROVIDE DADE COUNTY NOA SUBMITTAL THAT
 MATCHES NOA NOTED ON FLORIDA PRODUCT
 APPROVAL FOR PGT WINDOW MULLIONS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-02-05 Cont ID  
Sent By csiegber Date 2004-02-27 Time 12:31 Rev Time 1.00
Received By jgomez Date 2004-02-05 Time 18:31 Sent To PC
Notes
2004-02-05 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-ALL DRAWINGS TO HAVE ALL ARCHITECT'S
 INFORMATION AS REQUIRED BY CHAPTER
 481 FLORIDA STATUTES.
 2-PROVIDE COMPLETE CURRENT PRODUCT
 APPROVALS FOR ALL DOORS, WINDOWS,
 MULLIONS, GLASS BLOCK, ROOF TILE AND
 ALL STRUCTURAL CONNECTORS UNDER A
 SEPARATE PERMIT.
 3-DETAIL E/4 AND RESIDENTIAL NOTES ON
 DWG #2 DON'T MATCH. REVISE AS REQ'D.
 4-REVISE WINDOW BUCK DETAIL. SEE SECTION
 1707.4.4.2 FBC 2001.
 5-DWG #2: A)REVISE/CLARIFY TRUSS ANCHOR
 SCHEDULE.
 B)PROVIDE HOLD DOWN DETAILS AND CALCS
 AS SPECIFIED ON NOTE ON THIS DWG.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 6-SPECIFY ROOF TILE FASTENERS. SEE SEC.
 1606.3 FBC 2001 AND SEC. 104.2.1.1
 CITY AMENDMENTS TO FBC 2001.
 7-PROVIDE REVISED ROOF FRAMING PLAN
 SHOWING CHANGE OF BEAM AT REAR PORCH.
 WOOD TO MASONRY.
 8-SHEET #3:CLARIFY NOTE REGARDING UPLIFT
 CALCS AND CONNECTORS SELECTED.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-09 Cont ID  
Sent By dpalmer Date 2004-01-09 Time 10:32 Rev Time 0.33
Received By dpalmer Date 2004-01-09 Time 10:28 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-27 Cont ID  
Sent By csiegber Date 2004-02-27 Time 12:31 Rev Time 0.00
Received By csiegber Date 2004-02-27 Time 12:31 Sent To B
Notes
2004-02-27 00:00:00TO JG DESK/SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-02-11 Cont ID  
Sent By csiegber Date 2004-02-11 Time 16:07 Rev Time 0.00
Received By csiegber Date 2004-02-11 Time 16:07 Sent To B
Notes
2004-02-11 00:00:00TO JG DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-10 Cont ID  
Sent By mmclean Date 2004-01-06 Time 12:47 Rev Time 0.00
Received By shernand Date 2004-01-06 Time 12:18 Sent To  
Notes
2004-01-20 00:00:00TO JG DESK/RESUB
2004-01-06 00:00:00TO Z
 TO E/DP

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-01-14 Cont ID  
Sent By dpalmer Date 2004-01-09 Time 10:33 Rev Time 0.33
Received By pkrauss Date 2004-01-14 Time 15:01 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-01-16 Cont ID  
Sent By pkrauss Date 2004-01-14 Time 15:10 Rev Time 0.33
Received By kstevens Date 2004-01-16 Time 10:08 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-06 Cont ID  
Sent By mmclean Date 2004-01-06 Time 12:47 Rev Time 0.00
Received By mmclean Date 2004-01-06 Time 12:47 Sent To I
Notes
***NONE***