Plan Review Details - Permit 04010078
Plan Review Stops For Permit 04010078 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2004-02-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:29 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2004-02-06 |
Time |
14:02 |
Sent To |
PC |
|
Notes |
2004-02-06 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-PROVIDE COMPLETE CURRENT PRODUCT APPRO | | VAL FOR ALL DOORS, WINDOWS, MULLIONS, | | GLASS BLOCK, ROOF TILE AND ALL STRUC- | | TURAL CONNECTORS UNDER A SEPARATE | | PERMIT AS REQ'D BY BUILDING OFFICIAL. | | 2-DETAIL E/4 AND RESIDENTIAL NOTES ON | | DWG #2 DON'T MATCH. REVISE AS REQUIRED | | 3-CLARIFY/REVISE TRUSS ANCHOR SCHEDULE. | | 4-TYPICAL WALL SECTION DETAIL A/4: | | CLARIFY WHERE ARE TABLES 6 AND 8 FOR | | ROOF FASTENERS TAKEN FROM?. SEE SEC. | | 1606.3 FBC 2001 AND SEC. 104.2.1.1 | | CITY AMENDMENTS TO FBC 2001. | | 5-SHEET #7: A)REVISE/CLARIFY DESIGN | | PRESSURES ACCORDING TO SIZE/LOCATION. | | B)WINDOWS SHOWN ON ELEVATION DON'T MATCH | | WINDOW SCHEDULE. | | C)REVISE ALL NOTES ON FLOOR PLAN & ROOF | | FRAMING PLAN TO REFLECT CHANGE OF WOOD | | BEAM TO CONCRETE BEAM. | | 6-SHEET #3: CLARIFY NOTE REGARDING THE | | UPLIFT CALCS AND CONNECTOR SELECTED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2004-01-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-01-09 |
Time |
07:31 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-01-09 |
Time |
07:31 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-27 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-27 |
Time |
12:29 |
Sent To |
B |
|
Notes |
2004-02-27 00:00:00 | TO JG DESK/SUBMITTALS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-02-11 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-11 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-11 |
Time |
16:07 |
Sent To |
B |
|
Notes |
2004-02-11 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-02-06 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2004-01-06 |
Time |
13:42 |
Sent To |
PC |
|
Notes |
2004-01-20 00:00:00 | TO KS BOX | 2004-01-06 00:00:00 | TO Z | | TO E/DP |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-01-22 |
Time |
07:06 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2004-01-22 |
Time |
15:27 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-01-22 |
Time |
07:06 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-01-22 |
Time |
07:06 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-01-06 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-01-06 |
Time |
12:40 |
Sent To |
I |
|
Notes |
|
|
|