Plan Review Details - Permit 04010071
Plan Review Stops For Permit 04010071
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-06-23 Cont ID  
Sent By jgomez Date 2004-06-23 Time 11:39 Rev Time 0.50
Received By jgomez Date 2004-06-23 Time 11:39 Sent To PC
Notes
2004-06-23 00:00:00PRODUCT APPROVAL SUBMITTAL CHECKLIST:
 1-PROVIDE COPIES OF GARAGE DOOR DRAWINGS
 SUBMITTED TO SBCCI FOR APPROVAL. NEED
 DRAWINGS SIGNED AND SEALED ON DATE
 NOTED ON SBCCI EVALUATION REPORT.
 2-PROVIDE FLORIDA PRODUCT APPROVAL COVER
 PAGE FOR ENTRY DOOR THAT MATCHES DADE
 COUNTY NOA SUBMITTED. BENCHMARK AND
 THERMA-TRU ARE 2 DIFFERENT DOOR MODELS
 3-SIMONTON DOORS/WINDOWS PACKAGE IS
 INCOMPLETE. NEED FLORIDA PRODUCT
 APPROVAL COVER PAGEFOR FIXED WINDOWS
 AND SLIDING GLASS DOORS USED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-02-10 Cont ID  
Sent By csiegber Date 2004-02-27 Time 12:18 Rev Time 1.00
Received By jgomez Date 2004-02-06 Time 19:49 Sent To PC
Notes
2004-02-06 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE CURRENT PRODUCT APPRO
 VAL FOOR ALL DOORS, WINDOWS, MULLIONS,
 ROOF TILE, GLASS BLOCK AND ALL
 STRUCTURAL CONNECTORS UNDER A SEPARATE
 PERMIT AS REQ'D BY BUILDING OFFICIAL.
 2-DETAIL E/4 AND RESIDENTIAL NOTES ON
 DWG #2 DON'T MATCH. REVISE AS REUIRED.
 3-CLARIFY/REVISE TRUSS ANCHOR SCHEDULE.
 4-TYPICAL WALL SECTION A/4: CLARIFY
 WHERE ARE TABLES 6 AND 8 REFERING TO
 ROOF FASTENERS TAKEN FROM?. SECTION
 1606.3 FBC 2001 AND SEC. 104.2.1.1
 CITY AMENDMENTS TO FBC 2001.
 5-SHEET #7: A)REVISE/CLARIFY DESIGN
 PRESSURES SHOWN ON ELEVATION.
 B)REVISE ALL NOTES ON FLOOR PLAN & ROOF
 FRAMING PLAN TO REFLECT CHANGE OF BEAM
  
 6-SHEET #3: CLARIFY NOTE REGARDING THE
 UPLIFT CALCS AND CONNECTORS SELECTED.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-09 Cont ID  
Sent By dpalmer Date 2004-01-09 Time 06:39 Rev Time 0.33
Received By dpalmer Date 2004-01-09 Time 06:39 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-27 Cont ID  
Sent By csiegber Date 2004-02-27 Time 12:18 Rev Time 0.00
Received By csiegber Date 2004-02-27 Time 12:18 Sent To B
Notes
2004-02-27 00:00:00TO JG DESK/SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-02-11 Cont ID  
Sent By csiegber Date 2004-02-11 Time 16:09 Rev Time 0.00
Received By csiegber Date 2004-02-11 Time 16:09 Sent To B
Notes
2004-02-11 00:00:00TO JG DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-09 Cont ID  
Sent By jgomez Date 2004-02-09 Time 11:53 Rev Time 0.00
Received By jgomez Date 2004-01-06 Time 13:39 Sent To PC
Notes
2004-01-20 00:00:00TO KS BOX
2004-01-06 00:00:00TO Z
 TO E/DP

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-01-22 Cont ID  
Sent By kstevens Date 2004-01-21 Time 18:47 Rev Time 0.25
Received By pkrauss Date 2004-01-22 Time 15:32 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-01-21 Cont ID  
Sent By kstevens Date 2004-01-21 Time 18:46 Rev Time 0.33
Received By kstevens Date 2004-01-21 Time 18:44 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-01-06 Cont ID  
Sent By mmclean Date 2004-01-06 Time 12:19 Rev Time 0.00
Received By mmclean Date 2004-01-06 Time 12:18 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved