Plan Review Details - Permit 03121685
Plan Review Stops For Permit 03121685
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-03-18 Cont ID  
Sent By lsmith Date 2004-03-18 Time 11:05 Rev Time 1.50
Received By lsmith Date 2004-03-18 Time 11:05 Sent To  
Notes
2004-03-18 00:00:00PLANS MUST BE TAKEN BACK TO THE COUNTY
 AND THE IMPACT FEE STAMP PLACED ON PLANS
  
 WHEN PLANS STAMPED THE PERMIT CAN BE
 PRINTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-10 Cont ID  
Sent By btrobaug Date 2004-03-18 Time 08:35 Rev Time 0.00
Received By lsmith Date 2004-02-10 Time 10:11 Sent To  
Notes
2004-02-10 00:00:00BUILDING PLAN REVIEW FAILED:
  
 1.PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE
 WEBSITEWWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 WWW.FLORIDABUILDING.ORG
  
 2. PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE
 USED FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 3. SHOW DETAIL @ SECTION AT FRONT
 PORCH ENTRY TO SHOW TIE-IN TO GABLE.
  
 4. SPECIAL ROOF SHEATHING NAILING ZONE
 COMPLYING WITHREVISED TABLE 2306.1
 FASTENING SCHEDULE WPB AMENDMENTS TO FBC
  
 5.SPECIFY LIVE LOAD BOTTOM CORD TRUSS
 FOR STORAGE OR NO STORAGE PER TABLE
 1604.1 :
 ATTIC WITH STORAGE30 PSF
 ATTIC WITHOUT STORAGE 10 PSF
  
 6. PRODUCT APPROVAL FOR CLOPLAY GARAGE
 DOOR IS INCLUDED WITH APPLICATION.NO
 GARAGE SHOWN ON PLANS.REMOVE FROM
 PACKAGE.
  
 7. FRONT EXTERIOR DOOR PRODUCT APPROVAL
 MISSING. NOTE: PAPER WORK SUBMITTED
 REFERS TO ENTERGYENTRY SYSTEMS. NO
 RECORD OF SBCCI OR MIAMI DADE PRODUCT
 APPROVALS SUBMITTED OR STATE PRODUCT
 APPROVAL.
  
  
  
 8. A LETTER SIGNED & SEALED BY ENGINEER
 THAT STATES SOIL PREPARATION WAS
 COMPLETED AND BEARING VALUE OF 2000 PSF
 HAS BEEN ACHIEVED BEFORE CONSTRUCTION.
  
 9. HOUSE WILL BE CONSTRUCTED ACCORDING
 TO THE 2001 FBC AND WPB AMENDMENTS.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-03-18 Cont ID  
Sent By btrobaug Date 2004-03-18 Time 08:35 Rev Time 0.50
Received By btrobaug Date 2004-03-18 Time 08:25 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-23 Cont ID  
Sent By pkrauss Date 2004-03-18 Time 07:39 Rev Time 0.50
Received By btrobaug Date 2004-01-23 Time 17:32 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-04 Cont ID  
Sent By csiegber Date 2004-03-04 Time 16:45 Rev Time 0.00
Received By csiegber Date 2004-03-04 Time 16:45 Sent To P
Notes
2004-03-04 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-02-10 Cont ID  
Sent By mmclean Date 2004-01-28 Time 15:32 Rev Time 0.00
Received By csiegber Date 2003-12-31 Time 13:11 Sent To  
Notes
2004-01-28 00:00:001/28/04 PULLED OFF SFD RACK/TO Z RESUB
2004-01-14 00:00:0012/31/03 TO Z
 1/14/04 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-18 Cont ID  
Sent By pkrauss Date 2004-03-18 Time 07:18 Rev Time 0.33
Received By pkrauss Date 2004-03-18 Time 07:14 Sent To E
Notes
2004-03-18 00:00:00PROVISO:
 PER THE REVISION TO THE 2001 FBC(M)601.4
 EFFECTIVE JUNE 30, 2003:
  
 WHEN CALCULATING RETURN AIR FROM THE
 MASTER BEDROOM ALL SUPPLY AIR INTO THE
 SUITE IS TO BE INCLUDED FOR THE TOTAL OF
 SUPPLY AIR.
 I.E., 10" SUPPLY TO BEDROOM = 78 SQ IN
 4""MASTER CLOSET = 13 SQ IN
 4""MASTER BATHRM = 13 SQ IN
 TOTAL = 104 SQ IN X 1.5 = 156 SQ IN =
 15" RETURN AIR JUMPER.
  
 PLEASE REVISE RETURN AIR FOR THE MASTER
 BEDROOM TO REFLECT THE REQUIRED SIZE FOR
 A RETURN AIR JUMPER.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-01-30 Cont ID  
Sent By jleech Date 2004-03-13 Time 12:09 Rev Time 0.33
Received By pkrauss Date 2004-01-30 Time 12:46 Sent To P
Notes
2004-01-30 00:00:00DENIED:
 2001 FBC(M) 601.4 - BALANCED RETURN AIR
  
 PLEASE INDICATE ON PLAN WHICH METHOD
 WILL BE USED, DUCTED, RETURN JUMPER, OR
 TRANSFER GRILLE.PLEASE REFERENCE THE
 ATTACHED SCHEDULE FOR PROPER SIZING.
 PLANS ARE OTHERWISE CODE COMPLIANT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-03-13 Cont ID  
Sent By jleech Date 2004-03-13 Time 12:09 Rev Time 0.50
Received By jleech Date 2004-03-13 Time 12:09 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-02-04 Cont ID  
Sent By csiegber Date 2004-03-04 Time 16:45 Rev Time 0.33
Received By jleech Date 2004-02-04 Time 11:02 Sent To B
Notes
2004-02-04 00:00:00DENIED;
 W/M CANNOT DISCHARGE INTO THE WET VENT
 FOR BATH 1 SEE FBC PLUMBING SEC. 909.1
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 2 Status P Date 2004-01-28 Cont ID  
Sent By mmclean Date 2004-01-28 Time 15:32 Rev Time 0.00
Received By mmclean Date 2004-01-28 Time 15:32 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-01-07 Cont ID  
Sent By csiegber Date 2003-12-31 Time 13:11 Rev Time 0.00
Received By mmclean Date 2004-01-07 Time 16:32 Sent To  
Notes
2004-01-07 00:00:00DENIED, NEED TO MEET 10% OF LOT DEPT
 FOR REAR SETBACK AND 1000SQ FT OR 75%
 OF LANDSCAPE WHICHEVER IS LESS.
 DRIVEWAY CAN ONLY BE 10FT IT ALREADY
 AT THE 1000SQ FT. CALLED & LEFT MSG.
 SPOKE WITH CONTR WILL PICK UP & RESUBMIT
 FILE A MM