Plan Review Details - Permit 03121504
Plan Review Stops For Permit 03121504
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-01-20 Cont ID  
Sent By csiegber Date 2004-02-27 Time 12:31 Rev Time 2.00
Received By jgomez Date 2004-01-20 Time 15:13 Sent To M
Notes
2004-01-20 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE FLORIDA/SITE SPECIFIC
 PRODUCT APPROVAL FOR ALL WINDOW/DOOR
 TYPES, GLASS BLOCK, MULLIONS, ROOF
 TILE AND STRUCTURAL CONNECTORS.
 2-REVISE DETAIL E/4. FASTENER SPECIFIED
 DOESN'T PROVIDE 2" MIN. EMBEDMENT. SEC
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 3-PROVIDE ENGINEERING CALCS FOR NUMBER
 OF FASTENERS SPECIFIED FOR TRUSS
 ANCHORS SINCE THEY DIFFER FROM THOSE
 TESTED AND PUBLISHED BY USP TO COMPLY
 WITH SEC. 1609.4.3 FBC 2001 REGARDING
 THE STEEL STRESS.SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 4-REVISE DETAIL A/4. WHERE ARE TABLES 6
 AND 8 TAKEN FROM?. WE USE ASC7 7-98 OR
 FBC 2001.
 5-SHEET A-7: A)REVISE DESIGN PRESSURES @
 EXTERIOR OPENINGS. SEE TABLES 1606.2B
 AND 1606.2E FBC 2001.
 B)DESIGN PRESSURES SHOWN ON SHEET 7 AND
 SHEET 3 DON'T MATCH. REVISE AS REQ'D.
 C)REVISE REAR PORCH FLOOR PLAN AND ROOF
 FRAMING PLAN. CHANGE NOTES RELATED TO
 WOOD BM. SINCE IT WAS CHANGED TO CONC.
 BEAM. SEC. 104.2.1.2 CITY AMENDMENTS.
 D)WINDOWS SHOWN ON ELEVATION DON'T MATCH
 THOSE SPECIFIED ON WINDOW SCHEDULE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-01-12 Cont ID  
Sent By csiegber Date 2004-01-16 Time 16:55 Rev Time 2.00
Received By jgomez Date 2004-01-12 Time 17:26 Sent To PC
Notes
2004-01-12 00:00:00BUILDING REVIEW CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-PROVIDE COMPLETE FLORIDA/SITE SPECIFIC
 PRODUCT APPROVAL FOR: A)SLIDER WINDOW.
 B)GLASS BLOCK. C)ROOF TILE. D)SINGLE
 HUNG WINDOWS. E)ENTRY DOOR WITH SIDE-
 LITE ASEMBLY. F)SLIDING GLASS DOORS.
 G)WINDOW MULLIONS. H)TRUSS CONNECTORS.
 3-ARCHTECT TO HAVE ALL HIS INFORMATION
 AND PROVIDE ALL INFORMATION AS REQ'D
 BY CHAPTER 481 FLORIDA STATUTES WHEN
 SUBMITTING DWGS FOR PUBLIC RECORDS.
 4- 1HR FIRE RATED GLASS BLOCK ASSEMBLY
 NEED SPECIFIC UL LISTED ASSEMBLY AND
 REVISE DETAIL IDENTIFYING ALL REQ'D
 COMPONENTS ON SUCH ASSEMBLY. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 5-CLARIFY GARAGE DOOR BUCK SPECS. DETAIL
 E/4 AND NOTES ON DWG #2 DON'T MATCH.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 6-REVISE/UPDATE TRUSS ANCHOR SCHEDULE &
 ALL DETAILS THAT ARE AFFECTED BY SEC.
 1609.4.3 FBC REGARDING STEEL STRESS.
 B)SPECIFY SIZES FOR USP STRAP RT.SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 7-DESIGNER OF RECORD TO SPECIFY ROOF
 TILE FASTENER AS REQ'D BY SECTION
 104.2.1.1 CITY AMENDMENTS TO FBC 2001.
 8-REVISE WINDOW BUCK DETAIL. SEE SEC.
 1707.4.4.2 FBC 2001 FOR PROPER BUCK
 INSTALLATION.
 9-SHEET #7: A)CLARIFY WHERE IS USP EHUH
 28-3 CONNECTOR TAKEN FROM?. UNABLE TO
 FIND ON USP 2003 CATALOGUE.SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 B)MISSING ONE CONNECTOR FOR REAR PORCH
 GIRDER TRUSS.SECTION 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 C)CLARIFY CALCULATED DESIGN PRESSURES.
 WHY THE SAME PRESSURES FOR DIFFERENT
 SIZE AND LOCATION OF OPENING?.SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 D)REAR ELEVATION DOESN'T REFLECT TYPE OF
 WINDOWS SPECIFIED ON WINDOW SCHEDULE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-01-06 Cont ID  
Sent By jleech Date 2004-01-03 Time 11:53 Rev Time 0.33
Received By dpalmer Date 2004-01-06 Time 07:41 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-02-27 Cont ID  
Sent By csiegber Date 2004-02-27 Time 12:31 Rev Time 0.00
Received By csiegber Date 2004-02-27 Time 12:31 Sent To B
Notes
2004-02-27 00:00:00TO JG DESK/SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-11 Cont ID  
Sent By csiegber Date 2004-02-11 Time 15:58 Rev Time 0.00
Received By csiegber Date 2004-02-11 Time 15:58 Sent To B
Notes
2004-02-11 00:00:00TO JG DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-16 Cont ID  
Sent By csiegber Date 2004-01-16 Time 16:55 Rev Time 0.00
Received By csiegber Date 2004-01-16 Time 16:54 Sent To B
Notes
2004-01-16 00:00:00TO JG DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-12 Cont ID  
Sent By mmclean Date 2004-01-12 Time 17:42 Rev Time 0.00
Received By jgomez Date 2003-12-24 Time 13:18 Sent To PC
Notes
2003-12-29 00:00:0012/24/03 TO Z
 12/29/03 TO E

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-01-22 Cont ID  
Sent By pkrauss Date 2004-01-22 Time 13:51 Rev Time 0.25
Received By pkrauss Date 2004-01-22 Time 13:51 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-01-06 Cont ID  
Sent By jgomez Date 2004-01-20 Time 15:14 Rev Time 0.33
Received By pkrauss Date 2004-01-06 Time 13:54 Sent To B
Notes
2004-01-06 00:00:00DENIED:
 RETURN AIR JUMPER FROM THE MASTER
 BEDROOM IS NOT SIZED PROPERLY.ALL AIR
 TO THE MASTER SUITE IS TO BE INCLUDED
 IN THE CALCULATION FOR TOTAL SUPPLY
 AIR.RETURN AIR SHALL BE SIZED
 ACCORDING TO THE TOTAL OF SUPPLY AIR.
 PLEASE REVISE PLANS ACCORDINGLY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-01-03 Cont ID  
Sent By jleech Date 2004-01-03 Time 11:53 Rev Time 0.25
Received By jleech Date 2004-01-03 Time 11:53 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2004-01-06 Cont ID  
Sent By mmclean Date 2004-01-06 Time 12:07 Rev Time 0.00
Received By mmclean Date 2004-01-06 Time 12:07 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-12-24 Cont ID  
Sent By dpalmer Date 2004-01-06 Time 07:41 Rev Time 0.00
Received By mmclean Date 2003-12-24 Time 15:02 Sent To I
Notes
2003-12-24 00:00:00DENIED, NEED TO MEET FRONT SETBACK FOR
 FRONT LOAD GARAGE OF 20FT CALLED CONTR
 LEFT MSG